CTSL Testing (Dongguan) Co.,
Building 1, Houjie Road, Houjie Town, Guangdong Province Dongguan City, People’s Republic of China, Dongguan, People's Republic of China, Dongguan, China
Visit website- Accredited standards
- 120
- A2LA certificates
- 3
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 120 standard numbers and the 36 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM34
ASTM F381
ASTM F404
ASTM F406
ASTM F833
ASTM F963
ASTM F977
ASTM F1004
ASTM F1169
ASTM F1235
ASTM F1427
ASTM F1816
ASTM F1821
Show all 34
ASTM F1917
ASTM F1967
ASTM F2012
ASTM F2050
ASTM F2057
ASTM F2058
ASTM F2085
ASTM F2088
ASTM F2167
ASTM F2194
ASTM F2236
ASTM F2388
ASTM F2417
ASTM F2549
ASTM F2601
ASTM F2613
ASTM F2640
ASTM F2670
ASTM F2906
ASTM F2907
ASTM F3084
ASTM F3118
EN24
EN 581-1
EN 581-2
EN 1122
EN 1129-1
EN 1129-2
EN 1130-2
EN 1273
EN 1811
EN 1888-1
EN 1888-2
EN 1930
EN 12221-1
Show all 24
EN 12221-2
EN 12227
EN 12472
EN 12520
EN 12790-1
EN 14036
EN 14582
EN 14988
EN 15493
EN 16120
EN 16232
EN 17616
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC10
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62031+1 national
National versions in the same scope
AS/NZS 62031probably the same standard; matched by number only
IEC 62115+1 national
National versions in the same scope
AS/NZS 62115probably the same standard; matched by number only
IEC 62133-1+1 national
National versions in the same scope
AS/NZS 62133.1probably the same standard; matched by number only
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems+1 national
National versions in the same scope
AS/NZS 62133.2probably the same standard; matched by number only
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62560
IEC 60598 series9
IEC 60598-1Luminaires - Part 1: General requirements and tests+1 national
National versions in the same scope
AS/NZS 60598-1probably the same standard; matched by number only
IEC 60598-2-1+1 national
National versions in the same scope
AS/NZS 60598-2-1probably the same standard; matched by number only
IEC 60598-2-2+1 national
National versions in the same scope
AS/NZS 60598-2-2probably the same standard; matched by number only
IEC 60598-2-3+1 national
National versions in the same scope
AS/NZS 60598-2-3probably the same standard; matched by number only
IEC 60598-2-4+1 national
National versions in the same scope
AS/NZS 60598-2-4probably the same standard; matched by number only
IEC 60598-2-5+1 national
National versions in the same scope
AS/NZS 60598.2.5probably the same standard; matched by number only
IEC 60598-2-8
IEC 60598-2-13
IEC 60598-2-20+1 national
National versions in the same scope
AS/NZS 60598-2-20probably the same standard; matched by number only
IEC 62321 series9
IEC 62321-3-1
IEC 62321-4
IEC 62321-5
IEC 62321-6
IEC 62321-7-1
IEC 62321-7-2
IEC 62321-8
IEC 62321-10
IEC 62321-12
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN 71 series5
EN 71-1
EN 71-12
EN 71-15
EN 71-16
EN 71-17
ISO 8124 series4
ISO 8124-1Safety of toys - Part 1: Safety aspects related to mechanical and physical properties+1 national
National versions in the same scope
AS/NZS ISO 8124.1probably the same standard; matched by number only
ISO 8124-2Safety of toys - Part 2: Flammability+1 national
National versions in the same scope
AS/NZS 8124.2national version with changes
ISO 8124-3Safety of toys - Part 3: Migration of certain elements+1 national
National versions in the same scope
AS/NZS ISO 8124.3probably the same standard; matched by number only
ISO 8124-6Safety of toys - Part 6: Certain phthalate esters
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
ICES-001Industrial, Scientific and Medical (ISM) Equipment
ISO 18219-1Leather - Determination of chlorinated hydrocarbons in leather - Part 1: Chromatographic method for short-chain chlorinated paraffins (SCCPs)
ISO 18219-2Leather - Determination of chlorinated hydrocarbons in leather - Part 2: Chromatographic method for middle-chain chlorinated paraffins (MCCPs)
UN 38.3Lithium metal and lithium ion batteries
ASTM F963-23: Section 4.33; ASTM F963-23: Section 4.34; ASTM F963-23: Section 4.35; ASTM F963-23: Section 4.36; ASTM F963-23: Section 4.38; ASTM F963-23: Section 4.39; ASTM F963-23: Section 4.40; ASTM F963-23: Section 4.41; ASTM F381; ASTM F1816; ASTM F1917; ASTM F2058; ASTM F2417; ASTM F2601; ASTM F3084; EN 581-1; EN 581-2; EN 1129-1; EN 1129-2; EN 1130; EN 1273; EN 1888-1; EN 1888-2; EN 1930; EN 12221-1; EN 12221-2; EN 12227
16 CFR Part 1231; ASTM F404; 16 CFR Part 1233; ASTM F1235; 16 CFR Part 1236; ASTM F3118; 16 CFR Part 1220; ASTM F406; 16 CFR Part 1239; ASTM F1004; 16 CFR Part 1224; ASTM F2085; 16 CFR Part 1238; ASTM F2012; 16 CFR Part 1225; ASTM F2050; 16 CFR Part 1218; ASTM F2194; 16 CFR Part 1216; ASTM F977
16 CFR Part 1227; ASTM F833; 16 CFR Part 1229; ASTM F2167; 16 CFR Part 1237; ASTM F2640; 16 CFR Part 1235; ASTM F2388; 16 CFR Part 1230; ASTM F2549; 16 CFR Part 1219; ASTM F1169; 16 CFR Part 1217; ASTM F1821; 16 CFR Part 1222; ASTM F2906; 16 CFR Part 1234; ASTM F2670; 16 CFR Part 1228; ASTM F2907; 16 CFR Part 1226; ASTM F2236; 16 CFR Part 1223; ASTM F2088; 16 CFR Part 1232; ASTM F2613; 16 CFR Part 1215; ASTM F1967; 16 CFR Part 1213; 16 CFR Part 1513; ASTM F1427; 16 CFR Part 1261; ASTM F 2057; 16 CFR Part 1242; 16 CFR Part 1615; 16 CFR Part 1616; 16 CFR Part 1611; 16 CFR Part 1500.19; 16 CFR Part 1262; 16 CFR Part 1500.44
16 CFR Part 1500.48; 16 CFR Part 1500.49; 16 CFR Part 1500.50; 16 CFR Part 1500.51; 16 CFR Part 1500.52; 16 CFR Part 1500.53; 16 CFR Part 1501; 16 CFR Part 1505; IEC 62115; EN IEC 62115; BS EN IEC 62115; AS/NZS 62115; 16 CFR Part 1510; 16 CFR Part 1511; 16 CFR Part 1610; 16 CFR Part 1250; BS EN 71-1; EN 71-1; ISO 8124-1; AS/NZS ISO 8124.1; Toys Regulations SOR/2011-17; BS EN-71-2; EN-71-2; ISO 8124-2; AS/NZS 8124.2; ASTM F963-23: Section 4.1; ASTM F963-23: Section 4.2; ASTM F963-23: Section 4.3.7; ASTM F963-23: Section 4.4; ASTM F963-23: Section 4.5
ASTM F963-23: Section 4.6; ASTM F963-23: Section 4.7; ASTM F963-23: Section 4.8; ASTM F963-23: Section 4.9; ASTM F963-23: Section 4.10; ASTM F963-23: Section 4.11; ASTM F963-23: Section 4.12; ASTM F963-23: Section 4.13; ASTM F963-23: Section 4.14; ASTM F963-23: Section 4.15; ASTM F963-23: Section 4.16; ASTM F963-23: Section 4.17; ASTM F963-23: Section 4.18; ASTM F963-23: Section 4.19; ASTM F963-23: Section 4.20.2; ASTM F963-23: Section 4.21; ASTM F963-23: Section 4.22; ASTM F963-23: Section 4.23.1; ASTM F963-23: Section 4.24; ASTM F963-23: Section 4.25; ASTM F963-23: Section 4.26; ASTM F963-23: Section 4.27; ASTM F963-23: Section 4.28; ASTM F963-23: Section 4.30; ASTM F963-23: Section 4.31; ASTM F963-23: Section 4.32
Health Canada Product Safety Laboratory Method C07; ASTM F963-23: Sections 4.3.5.1(2), 4.3.5.2; 16 CFR Part 1303; CPSC-CH-E1003-09.1; 16 CFR Part 1307; CPSC-CH-E1001-08.3; CPSPC-CH-E1002-08.3; EN 1122; BS EN 1122; IEC 62321-5; BS EN 62321-5; EN 62321-5; IEC 62321-4; BS EN 62321-4; EN 62321-4; EN-71, Part 3; Health Canada Product Safety Laboratory Method C34.3; SOR/2016-188; ISO 8124-6; CPSC-CH-C1001-09.4; ASTM F963-23, Section 4.3.8; IEC 62321-6; BS EN 62321-6; EN 62321-6; IEC 62321-12; IEC 62321-8; BS EN 62321-8; EN 62321-8
AfPS GS 2019:01 PAK; IEC 62321-10; IEC 62321-3-1; BS EN 62321-3-1; EN 62321-3-1; IEC 62321-7-1; BS EN 62321-7-1; EN 62321-7-1; IEC 62321-7-2; BS EN 62321-7-2; EN 62321-7-2; EN 14582; EN 1811; BS EN 1811; EN 12472; EN 71-12; EN 71-15; EN 71-16; EN 71-17; ISO 18219-1; ISO 18219-2
EN 12520; EN 12790; EN 14036; EN 14988; EN 15493; EN 16120; EN 16232; EN 17616; SOR/2016-152; SOR/2016-167; SOR/2016-165; SOR/2016-185
CFR 47 FCC Part 15 Subpart B (using ANSI C63.4:2014); CFR 47 FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; ICES-005; CISPR 14.1; EN IEC 55014-1; AS/NZS CISPR 14.1; BS EN IEC 55014-1; J55014-1; CISPR 15; EN 55015; AS/NZS CISPR 15; BS EN 55015; J55015; EN 55032; BS EN 55032; CISPR 32; AS/NZS CISPR 32; J55032; EN IEC 55011; CISPR 11; AS/NZS CISPR 11; J55011; BS EN 55011; EN 60601-1-2; EN IEC 61000-3-2; IEC 61000-3-2: BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN 61000-4-3; IEC 61000-4-3; BS EN 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN IEC 61000-4-6; IEC 61000-4-6; BS EN IEC 61000-4-6; EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8; EN IEC 61000-4-11; IEC 61000-4-11; BS EN IEC 61000-4-11; EN 55035; BS EN 55035; CISPR 35; EN IEC 55014-2; BS EN IEC 55014-2; CISPR 14-2; EN IEC 61547; BS EN IEC 61547; IEC 61547; EN IEC 61000-6-3; IEC 61000-6-3; BS EN IEC 61000-6-3; AS/NZS 61000-6-3; EN IEC 61000-6-1; IEC 61000-6-1; BS EN IEC 61000-6-1; EN IEC 61000-6-4; IEC 61000-6-4; BS EN IEC 61000-6-4; AS 61000-6-4; EN IEC 61000-6-2; IEC 61000-6-2; BS EN IEC 61000-6-2; EN IEC 61326-1
IEC 62368-1; EN IEC 62368-1; BS EN 62368-1; AS/NZS 62368.1; UL62368-1; CAN/CSA-C22.2 NO. 62368-1; EN 60598; IEC60529; IEC 62133-1; EN 62133-1; BS EN 62133-1; AS/NZS 62133.1; IEC 62133-2; EN 62133-2; BS EN 62133-2; AS/NZS 62133.2; UL 2054; UL 2056; UL 4200A; UN38.3; 16 CFR Part 1263; UL1642; ANSI C18.3M; EC 60598-1; EN IEC 60598-1; BS EN IEC 60598-1; AS/NZS 60598-1; IEC 60598-2-1; EN IEC 60598-2-1; BS EN IEC 60598-2-1; AS/NZS 60598-2-1; IEC 60598-2-2; EN IEC 60598-2-2; BS EN IEC 60598-2-2; AS/NZS 60598-2-2; IEC 60598-2-3; EN 60598-2-3; BS EN 60598-2-3; AS/NZS 60598-2-3; IEC 60598-2-4; EN 60598-2-4; BS EN 60598-2-4; AS/NZS 60598-2-4; IEC 60598-2-13; EN 60598-2-13; BS EN 60598-2-13; IEC 60598-2-20; EN IEC 60598-2-20; BS EN IEC 60598-2-20; AS/NZS 60598-2-20; IEC 62031; EN IEC 62031; BS EN IEC 62031; AS/NZS 62031; IEC 62560; EN IEC 62560; BS EN IEC 62560; AS/NZS 620560; UL 1993; UL 1598; UL 153; UL 8750; UL 588; IEC 60598-2-5; EN 60598-2-5; BS EN 60598-2-5; AS/NZS 60598.2.5; IEC 60598-2-8; EN 60598-2-8; BS EN 60598-2-8
ISO 8124-3; AS/NZS ISO 8124.3; Health Canada Product Safety Laboratory Method C02.7; SOR/2016-193; Health Canada Product Safety Laboratory Method C02.3.1; Health Canada Product Safety Laboratory Method C02.4.1; SOR/2018-83; Health Canada Product Safety Laboratory Method C02.2.2; SOR/2016-193; Health Canada Product Safety Laboratory Method C02.3.2; SOR/2018-83
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
18 lines
ISO/IEC 17025
Active7556.01
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active7556.02
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active7556.03
The scope document we hold says it is valid until 2027-08-31.
Labs with overlapping accredited scope in China
- MRT Technology (Suzhou) Co.,Suzhou, JiangsuA2LAShares 3 accredited test methodsANSI C63.4:2014ICES-001IEC 62368-1
- Shenzhen Huaxia Testing Technology Co.,shenzhenA2LAShares 3 accredited test methodsANSI C63.4:2014ICES-001IEC 62368-1
- Shenzhen United Testing Technology Co.,Shenzhen, GuangdongA2LAShares 3 accredited test methodsANSI C63.4:2014ICES-001IEC 62368-1
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 62368-1
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 2 accredited test methodsANSI C63.4:2014ICES-001
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.