What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 6 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 11138-1Sterilization of health care products - Biological indicators - Part 1: General requirements
ISO 11138-7Sterilization of health care products - Biological indicators - Part 7: Guidance for the selection, use and interpretation of results
ISO 11737-1Sterilization of health care products - Microbiological methods - Part 1: Determination of a population of microorganisms on products
ISO 11737-2Sterilization of health care products - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
USP 85
PN-EN ISO 11737-2; Ph.Eur., 2.6.1; PN-EN ISO 11737-1; Ph.Eur., 2.6.12; Ph.Eur., 2.6.14; 5.1.10; USP <85> i <161>; LAB-16.12.00; LAB-16.13.00; PN-EN ISO 18593; LAB-16.10.00; Ph.Eur., 2.6.14; 5.1.10; USP <85> i <161>; Ph.Eur.; LAB-16.09.00 w oparciu o PN-EN ISO 11138-1, PN-EN ISO 11138-7; LAB-16.09.00 w oparciu o instrukcje producentów
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
2 lines
ISO/IEC 17025
ActiveAB 1575
The scope document we hold says it is valid until 2027-09-01.
Accredited scope, certificate AB 1575
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA
Zakres akredytacji Nr AB 1575
Scope of accreditation No. AB 1575
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1575
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 14 z/of 01.08.2025
KIEROWNIK DZIAŁU AKREDYTACJI
BADAŃ I CERTYFIKACJI ŻYWNOŚCI
HANNA TUGI
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1575 z dnia 09.07.2019 r.
Cykl akredytacji od 21.08.2023 r. do 01.09.2027 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1575 of 09.07.2019
Accreditation cycle from 21.08.2023 to 01.09.2027
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 14, 01.08.2025 str. 1/3
Nazwa i adres / Name and address
SteriPack Medical Poland Sp. z o. o.
Łęg, ul. Japońska 1
55-220 Jelcz-Laskowice
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
B/17, B/28
K/3, K/17, K/28
K/57/P
Badania biologiczne / wyroby inne (wyroby medyczne); woda / Biological tests of other products (medical
devices); water
Badania mikrobiologiczne / obiekty i materiały biologiczne przeznaczone do badań ; wyroby inne (wyroby
medyczne), woda / Microbiological tests of biological items and materials for testing ; other products (medical
devices), water
Badania mikrobiologiczne oraz pobieranie obiektów z obszaru produkcji (powietrze, powierzchnie) /
Microbiological tests and sampling objects from production area (air, surfaces)
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1575 | - |
| 2 | PN-EN ISO 11737-2; Ph.Eur., 2.6.1; PN-EN ISO 11737-1; Ph.Eur., 2.6.12; Ph.Eur., 2.6.14; 5.1.10; USP <85> i <161>; LAB-16.12.00; LAB-16.13.00; PN-EN ISO 18593; LAB-16.10.00; Ph.Eur., 2.6.14; 5.1.10; USP <85> i <161>; Ph.Eur.; LAB-16.09.00 w oparciu o PN-EN ISO 11138-1, PN-EN ISO 11138-7; LAB-16.09.00 w oparciu o instrukcje producentów | Water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- AGRO-VET Wojciech WieliczkoWrocław · ~28 kmPCAShares 1 accredited materialWater
- Dorota Prządo DM Laboratorium Analiz ŚrodowiskowychWrocław · ~28 kmPCAShares 1 accredited materialWater
- EKOLABOS Sp. z o.o.Wrocław · ~28 kmPCAShares 1 accredited materialWater
- Ekologis Piotr Szymański Spółka KomandytowaWrocław · ~28 kmPCAShares 1 accredited materialWater
- ZEC DIAGPOMWrocław · ~28 kmPCAShares 1 accredited materialWater
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.