MG-ZfP
An der Räst 3, 56727, St. Johann, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at MG-ZfP?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-19485-01-00Active
Certificates and scope
1ISO/IEC 17025
ActiveD-PL-19485-01-00
Accredited scope, certificate D-PL-19485-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | ndt | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | Metal | - |
| 2 | ndt | DIN EN ISO 5579; DIN EN ISO 17636-1; DIN EN 12681-1; DIN EN 10160; DIN EN 10228-3; DIN EN 10228-4; DIN EN 10306; DIN EN 10307; DIN EN 10308; DIN EN 12680-1; DIN EN 12680-2; DIN EN 12680-3 | Metal | - |
| 3 | ndt | DIN EN ISO 16809; DIN EN ISO 13588; DIN EN ISO 17405; DIN EN ISO 17640; DIN EN ISO 20601; SEP 1916; SEP 1917; SEP 1920; SEP 1923; DIN EN 1369; DIN EN 10228-1; DIN EN ISO 9934-1; DIN EN ISO 17638 | ferritischer Stahlrohre; Rohre aus ferritischen Stählen; Schmiedestücken aus Stahl; Schweißverbindungen; Halbzeug | - |
| 4 | ndt | DIN EN 1371-1; DIN EN 1371-2; DIN EN 10228-2; DIN EN ISO 3452-1; DIN EN ISO 17635; DIN EN 1370; DIN EN 13018; DIN EN ISO 17637; DIN 50159-1; DIN EN ISO 16859-1 | Metal | - |
| 5 | ndt | AD 2000-Merkblatt HP 5/3; DVGW GW 350; ASME BPVC.V-2021 | Schweißverbindungen an Rohrleitungen aus Stahl | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- RSE Röntgen Service EglyMannheim · ~132 kmDAKKSShares 5 accredited methods and materialsEN 10160EN ISO 17640EN ISO 9001
- CEWUS Chemnitzer Werkstoff- und Oberflächentechnik GmbH CEWUS Erstes Chemnitzer Werkstoff- und SchadensanalyselaborChemnitz · ~366 kmDAKKSShares 5 accredited methods and materialsEN 10160EN ISO 17640EN ISO 9001
- wbm Prüflabor GmbHEberswalde · ~580 kmDAKKSShares 5 accredited methods and materialsEN 10160EN ISO 17640EN ISO 9001
- Dreifeld GmbH & Co. KGLauffen · ~71 kmDAKKSShares 4 accredited methods and materialsEN 10160EN ISO 17640EN ISO 9001
- MAX STREICHER GmbH & Co. Kommanditgesellschaft auf Aktien SGU-Q Abteilung (Prüflabor)Niederwinkling · ~257 kmDAKKSShares 4 accredited methods and materialsEN 10160EN ISO 17640EN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.