Eurac Research - Istituto per le Energie Rinnovabilii
Via Volta 13/A-B, 39100, Bolzano, Italy
Visit website- Accredited standards
- 13
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 13 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
EN6
EN 12102-1
EN 12102-2
EN 14511-3
EN 14511-4
EN 14825
EN 16147
IEC4
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61215-1-1Some clauses
Limits written next to it
solo/only CEI EN 61215-1-1:2016 §
IEC 61215-2Some clauses
Limits written next to it
CEI EN 61215-2:2017 § 4.6.1, §
IEC 61215-2:2016 § 4.6.1, §
IEC 61215-2:2021 §4.11.4, §4.11.5,
ISO3
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 10077-1Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General
ISO 10077-2Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
CEI EN 60068-2-1:2007; IEC 60068-2-1:2007; CEI EN 60068-2-2:2008; IEC 60068-2-2:2007; EN ISO 10077-2:2017; EN ISO 10077-2:2017/A1:2025; UNI EN ISO 10077-2:2025; UNI EN 12102-1:2022 + UNI EN ISO 3744:2010; EN ISO 10077-1:2017; UNI EN ISO 10077-1:2018; CEI EN 61215-1-1:2016 + CEI EN 61215-2:2018; IEC 61215-1-1:2016 + IEC 61215-2:2016/Cor1:2018; CEI EN IEC 61215-1-1:2021 + CEI EN IEC 61215-2:2021; IEC 61215-1-1:2021 + IEC 61215-2:2021; UNI EN 14825:2019; UNI EN 14825:202
UNI EN 14511-4:2018; UNI EN 14511-3:2018; UNI EN 14511-4:2022; UNI EN 14511-3:2022; UNI EN 12102-2:2019; UNI EN ISO 3744:2010; UNI EN 16147:2017; UNI EN 16147:2023
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01546
Accredited scope, certificate 01546
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CEI EN 60068-2-1:2007; IEC 60068-2-1:2007; CEI EN 60068-2-2:2008; IEC 60068-2-2:2007; EN ISO 10077-2:2017; EN ISO 10077-2:2017/A1:2025; UNI EN ISO 10077-2:2025; UNI EN 12102-1:2022 + UNI EN ISO 3744:2010; EN ISO 10077-1:2017; UNI EN ISO 10077-1:2018; CEI EN 61215-1-1:2016 + CEI EN 61215-2:2018; IEC 61215-1-1:2016 + IEC 61215-2:2016/Cor1:2018; CEI EN IEC 61215-1-1:2021 + CEI EN IEC 61215-2:2021; IEC 61215-1-1:2021 + IEC 61215-2:2021; UNI EN 14825:2019; UNI EN 14825:202 | Apparecchiature elettriche, elettroniche e meccaniche, componenti e materiali/Electric, electronic and mechanical equipment, components and materials; Chiusure oscuranti /Shutters, Finestre/Windows, Porte/Doors; Condizionatori d'aria/Air conditioners, Deumidificatori/Dehumidifiers, Pompe di calore per il riscaldamento e il raffreddamento degli ambienti/Heat pumps for space heating and cooling, Refrigeratori di liquido/Liquid chilling packages, Refrigeratori di processo/Process chillers; Finestre/Windows, Porte/Doors; Moduli fotovoltaici (FV) per applicazioni terrestri in silicio cristallino/Crystalline silicon terrestrial photovoltaic (PV) modules; Pompe di calore con compressore elettrico per il riscaldamento e il raffrescamento degli ambienti/Heat pumps with electrically driven compressors for space heating and cooling, Refrigeratori di liquido/Liquid chilling packages, Refrigeratori di processo/Process chillers | See scope document |
| 2 | UNI EN 14511-4:2018; UNI EN 14511-3:2018; UNI EN 14511-4:2022; UNI EN 14511-3:2022; UNI EN 12102-2:2019; UNI EN ISO 3744:2010; UNI EN 16147:2017; UNI EN 16147:2023 | - | 0 to 250 kW |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.