Registers refreshed 2026-11-08.See refresh dates
Italy

INDUSTRIAL SERVICES

Via Aliano 25, 71042, Cerignola, Italy

Visit website
ACCREDIA 00861ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
17
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 17 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO11
ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 16649-2Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli - Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide
ISO 18593Microbiology of the food chain - Horizontal methods for surface sampling
ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
APAT3
APAT CNR IRSA 1030 Man 29 2003
APAT CNR IRSA 7010 C Man 29 2003
APAT CNR IRSA 7040 C Man 29 2003
EN3
EN 12457-2Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 2: One stage batch test at a liquid to solid ratio of 10 l/kg for materials with particle size below 4 mm (without or with size reduction)
EN 13037
EN 15408Solid recovered fuels - Methods for the determination of sulphur (S), chlorine (Cl), fluorine (F) and bromine (Br) content

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.

Scope as published by ACCREDIA

3 lines
ACCREDIA

ISO/IEC 17025

Active

00861

View scope

Accredited scope, certificate 00861

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; ISO 11731:2017; APAT CNR IRSA 7010 C Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; ISPRA Man 117 2014; ISO 9308-1:2014/Amd 1:2016; APAT CNR IRSA 3030 Man 29 2003; UNI EN ISO 7899-2:2003; UNI ISO 23695:2023Drinking waterSee scope document
2APAT CNR IRSA 7040 C Man 29 2003; UNI ISO 16649-2:2010; ISO 21528-2:2017; UNI EN ISO 6579-1:2020; ISO 4832:2006; UNI EN ISO 4833-1:2022; UNI EN 13037:2012; UNI EN 15408:2011 + UNI EN ISO 10304-1:2009; CNR IRSA 1 Q 64 Vol 3 1985 + APAT CNR IRSA 2060 Man 29 2003; UNI EN 12457-2:2004, UNI ISO 23695:2023; UNI EN 12457-2:2004, APAT CNR IRSA 2060 Man 29 2003; ISO 18593:2018 escl cap 7 e 8 + UNI ISO 16649-2:2010Food industry environment samples2 to 10.01
3APAT CNR IRSA 6010 Man 29 2003; APAT CNR IRSA 1030 Man 29 2003; UNI 10802:2023; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met I.1Waste water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Aliano 25, Cerignola, 71042, IT

41.26001, 15.89132

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.