HAGER ELECTRO

132 Boulevard d'Europe, 67210, OBERNAI (67348), France

COFRAC 1-0145ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
11
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 11 scope lines.

COFRAC certificate 1-0145 · 11 lines

LineMethodMatrixRange
1NF EN ISO/IEC 17025--
2-Low-voltage industrial apparatus; Electrical apparatus components used in domestic and/or similar installations; Various electrical (or electronic) apparatus
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 3/13 Section Laboratoires ANNEXE TECHNIQUE à l’attestation N° 1-0145 rév. 12 L’accréditation concerne les prestations réalisées par : HAGER ELECTRO SAS 132 Boulevard d'Europe 67210 OBERNAI (67348) Dans son unité : - LABORATOIRE ELECTRICAL DISTRIBUTION SYSTEMS Elle est accordée selon le périmètre suivant : Électricité / Appareillage industriel basse tension Electricity / Low-voltage industrial apparatus / Essais de sécurité et de performance (13) / Safety and performance tests (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues Electricity / Electrical apparatus components used in domestic and/or similar installations / Essais de sécurité et de performance (21) / Safety and performance tests (21) Électricité / Équipements électriques (ou électroniques) divers Electricity / Various electrical (or electronic) apparatus / Essais de compatibilité électromagnétique (107) / Electromagnetic compatibility tests (107) Pour tous les essais concernant cette accréditation : (*) Portée FLEX2 : Le laboratoire est reconnu compétent pour adopter toute méthode reconnue dans le domaine couvert par la portée générale. La liste exhaustive des méthodes proposées sous accréditation est mise à disposition par le laboratoire. For all tests concerning this accreditation: (*) FLEX2 scope: The laboratory is considered competent to adopt any recognized test method in the field covered by the general scope. The exhaustive list of revisions of test standards implemented is made availabale by the laboratory.
-
3-Low-voltage industrial apparatus; Electrical apparatus components used in domestic and/or similar installations
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 4/13 Portée générale / general scope : Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 1 Échauffement aux bornes Temperature-rise of terminals Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Température Temperature Mesure de la température à proximité d'une borne Measurement of the temperature near a terminal 2 Bornes sans vis Screwless terminals Tension Voltage Mesure de la chute de tension aux bornes (essai cyclique sous courant et température définis) Measurement of the voltage drop on terminals (cyclic test under defined current and temperature) 3 Échauffement d'une bobine par variation de résistance Temperature-rise of a coil by resistance variation Température, résistance Temperature, resistance Mesure de la résistance d'une bobine à température ambiante puis après une période d'échauffement et calcul de l'échauffement obtenu Measurement of the resistance of a coil at ambient temperature then after a period of heating and calculation of the heating value obtained 4 Mesure de la puissance dissipée Measurement of power loss Tension, courant, puissance Voltage, current, power Mesure de la chute de tension aux bornes sous I nominal et calcul de la puissance dissipée Measurement of the voltage drop on terminals under rated current and calculation of power dissipation 5 Essai de caractéristique de déclenchement différentiel Test of differential tripping characteristic Tension, courant, temps Voltage, current, time Mesure du seuil de déclenchement différentiel et du temps de déclenchement différentiel Measurement of the differential tripping threshold and the differential tripping time 6 Essai de caractéristique de déclenchement disjoncteurs Test of circuit breaker’s tripping characteristic Tension, courant, temps Voltage, current, time Mesure de temps de déclenchements et de non- déclenchements Measurement of the tripping and non-tripping time
-
4-Appareillage industriel basse tension; Éléments d’appareillage électrique pour installations domestiques et analogues
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 5/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 7 Performances en court-circuit Short-circuit performance Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Aptitude au fonctionnement dans des conditions de court-circuit. Tension, courant, facteur de puissance, temps, énergie d'arc Operability under short-circuit conditions. Voltage, current, power factor, time, arc energy Vérification du comportement des produits en court-circuit Verification of the behaviour of products during short-circuit 8 Vérification de la résistance à la chaleur (essai à la bille) Verification of the resistance to heat (ball test) Température, temps, force, dimension Temperature, time, force, dimension Déterminer le diamètre de l’empreinte laissée par une bille de diamètre 5 mm après exposition à une température élevée Determine the diameter of the imprint left by a ball with a diameter of 5 mm following exposure to a high temperature 9 Vérification de la résistance à la chaleur anormale et au feu (essai au fil incandescent) Verification of the resistance to abnormal heat and fire (glow wire test) Temps, distance, force, température Time, distance, force, temperature Tenue au fil incandescent des matériaux isolants Withstandof insulating materials to the glow wire 10 Vérification de la protection contre la rouille Verification of rust protection Examen visuel, température Visual examination, temperature Vérifier que les parties en métaux ferreux soient convenablement protégées contre la rouille Check that the ferrous metal parts are suitably protected against rust 11 Vérification de la tenue aux courants de cheminements Verification of the withstandto tracking currents Tension, courant, temps, Résistivité, force, distance Voltage, current, time, resistivity, force, distance Évaluer la résistance relative au cheminement des isolants électriques solides, sous contrainte électrique, à l’action d’eau contenant des impuretés ioniques Assess the relative resistance of solid electrical insulator to tracking, under electrical stress, to the action of water containing ionic impurities
-
5-Appareillage industriel basse tension; Éléments d’appareillage électrique pour installations domestiques et analogues
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 6/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 12 Indélébilité du marquage Indelibility of the marking Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Durabilité des marquages Durability of markings Vérification de la tenue des marquages par frottement Verification of markings resistance to rubbing 13 Protection contre les chocs électriques Protection against electric shocks Non accessibilité à des parties actives No accessibility to live parts Vérification à l'aide du doigt d'épreuve normalisé du non contact Verification using the standardised non-contact test finger 14 Essais de traction et de torsion (flexion) Pull-out test and flexion test Vérification de la résistance mécanique des parties testées (fixation du câble et autres parties, serrage des bornes…). Force, couple, temps, distance Verification of the mechanical resistance of tested parts (fastening of the cable and other parts, tightening of terminals…). Force, torque, time, distance Vérification de la tenue des conducteurs soumis à un effort de traction et de torsion dans des bornes à vis ou sans vis Verification of the withstand of conductors subjected to a pull-out and flexion load in the screwed or screwless terminals 15 Essai de déflexion Deflection test Tension, courant, temps, mesure angulaire, distance Voltage, current, time, angle measurement, distance Mesure des chutes de tension sur des bornes sans vis équipées de conducteurs soumis à des efforts Measurement of voltage drops on screwless terminals fitted with conductors subjected to stresses 16 Prescriptions constructives (état des contacts) Constructive provisions (condition of contacts) Conformité de la construction aux exigences Compliance of the construction to requirements Vérifier la concordance entre l'état des contacts et la signalisation Check the consistency between the contacts condition and the indicator
-
6-Appareillage industriel basse tension; Éléments d’appareillage électrique pour installations domestiques et analogues
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 7/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 17 Tenue à un couple de serrage imposé (vis, parties transportant le courant et connexions) Withstand to an imposed tightening torque (screws, parts carrying the current and connections) Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Couple, examen visuel Torque, visual examination Serrage et desserrage successifs Successive tightening and loosening 18 Mécanisme (pré-fermeture du Neutre) Mechanism (neutral pre-closing) Examen visuel, temps Visual examination, time Fermeture du produit et vérification visuelle Product closing and visual check 19 Résistance au vieillissement, à la pénétration nuisible de l'eau et à l'humidité Resistance to ageing, harmful penetration of water and humidity Mesure de la température et de l’humidité pendant l'essai, temps, tension Measurement of temperature and humidity during the test, time, voltage Essai de température et d'humidité Temperature and humidity test 20 Résistance d'isolement Insulation resistance Tension, résistance, temps Voltage, resistance, time Mesure de la résistance d'isolement sous 500 V continu Measurement of the insulation resistance under 500 V DC 21 Rigidité diélectrique Dielectric strength Tension, temps Voltage, time Tenue à une tension élevée (fréquence industrielle) High voltage withstand (industrial frequency) 22 Rigidité diélectrique Dielectric strength Tension, temps Voltage, time Tenue à une tension de choc 1,2/50 µs Surge voltage withstand 1.2/50 µs
-
7-Appareillage industriel basse tension; Éléments d’appareillage électrique pour installations domestiques et analogues
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 8/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 23 Pouvoir de fermeture et de coupure - Endurance électrique Making and breaking capacity - Electrical endurance Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Aptitude au fonctionnement dans des conditions normales. Tension, courant, facteur de puissance, temps, nombre de manœuvres Operability under normal conditions. Voltage, current, power factor, time, number of operations Application d'un nombre de manœuvres déterminé en charge Application of a number of determined operations under load 24 Résistance mécanique Mechanical resistance Énergie de choc, distance, non détérioration du produit Impact energy, distance, lack of product deterioration Application de chocs avec le marteau pendulaire Application of impacts using a pendulum hammer 25 Lignes de fuite, distances d'isolement dans l'air Clearance and creepage distances Distance Distance Mesure des lignes de fuite et distances d'isolement Measurement of clearance and creepage distances 26 Tension et courant en charge et à vide Voltage and current under and without load Tension, courant Voltage, current Mesure d'une tension et d'un courant Measurement of voltage and current 27 Manœuvres et limites de fonctionnement Operations and operating limits Tension, courant, température Voltage, current, temperature Contrôle de la bonne fermeture et ouverture sous condition de température et de tensions extrêmes Check of correct closing and opening under extreme temperature and voltage conditions 28 Secousses mécaniques Mechanical shaking Distance, force, raideur de ressort, fréquence, temps Distance, force, spring stiffness, frequency, time Application de secousses à un produit fermé Application of shakes to a closed product
-
8-Low-voltage industrial apparatus; Electrical apparatus components used in domestic and/or similar installations
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 9/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 29 Force verticale vers le bas Downward vertical force Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Force, examen visuel Force, visual examination Vérification de la tenue du couvercle dans le cas de l'application d'une force verticale ou de la tenue du produit sur le rail Verification of the cover withstand in the case of a vertical force be applied or the product holding on a rail 30 Dispositif de contrôle Device verification Aptitude au fonctionnement par simulation d’un courant de défaut Operability by simulating a defective current Mesure de la résistance test après plusieurs déclenchements Measurement of the test resistance after several trips 31 Essais climatiques 28 jours humides 28 humid days climatic tests Mesure de la température et de l’humidité pendant l'essai, temps, tension Measurement of temperature and humidity during the test, time, voltage Essai cyclique de température et d'humidité Cyclic temperature and humidity test 32 Onde de courant oscillatoire amortie 0,5 µs / 100 kHz Ring wave 0.5 µs / 100 kHz Tension, courant, temps Voltage, current, time Vérification du non déclenchement des produits lorsque l'on génère une onde de courant oscillatoire amortie Verification that products do not trip when generating a ring wave 33 Onde de courant 8/20 µs Current surge 8/20 µs Tension, courant, temps Voltage, current, time Vérification du comportement aux ondes de courant Verification of the behaviour in the presence of current surges
-
9-Low-voltage industrial apparatus; Electrical apparatus components used in domestic and/or similar installations
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 10/13 Électricité / Appareillage industriel basse tension (13) Electricity / Low-voltage industrial apparatus (13) Électricité / Éléments d’appareillage électrique pour installations domestiques et analogues (21) Electricity / Electrical apparatus components used in domestic and/or similar installations (21 ) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Measured Characteristics Principe de la méthode Principle of the method 39 Vérification de la caractéristique de fonctionnement Verification of the operating characteristics Appareillage industriel basse tension Low-voltage industrial apparatus Éléments d’appareillage électrique pour installations domestiques et analogues Electrical apparatus components used in domestic and/or similar installations Tension, courant, temps Voltage, current, time Génération de différents défauts : défaut d’arc série – défaut d’arc parallèle – essai d’aveuglement – déclenchement indésirable Generation of different faults: serie arc fault - parallel arc fault - masking test - unwanted tripping
-
10-Electricity / Various electrical (or electronic) apparatus
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 11/13 Électricité / Équipements électriques (ou électroniques) divers (107) Electricity / Various electrical (or electronic) apparatus (107) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Characteristic measured Principe de la méthode Principle of the method 34 Immunité aux décharges électrostatiques (DES) Electrostatic discharges (ESD) immunity Interrupteurs différentiels RCCBs Interrupteurs différentiels avec protection contre les surintensités RCBOs Caractéristiques fonctionnelles de l'équipement Functional characteristics of the equipment Application de DES dans l'air et au contact de l'objet soumis à essai au moyen d'un générateur de DES Application of ESD into the air and on contact with the item submitted for testing by the mean of an ESD generator 35 Immunité aux transitoires rapides en salves Fast transient bursts immunity Caractéristiques fonctionnelles de l'équipement Functional characteristics of the equipment Injection capacitive de la perturbation transitoire rapide répétitive sur les accès d'alimentation, de commande et de signal de l'objet soumis à essai au moyen d'un générateur de transitoires rapides en salves Capacitive injection of the repetitive fast transient disturbance on the power supply, control and signal ports of the item submitted for testing by the mean of a fast transient burst generator 36 Immunité aux transitoires lents (onde de chocs électriques) Slow transient immunity (electric surges wave) Caractéristiques fonctionnelles de l'équipement Functional characteristics of the equipment Injection capacitive de la perturbation transitoire lente (onde de choc électrique) sur les lignes d'alimentation et d'interconnexion de l'objet soumis à essai au moyen d’un générateur de transitoires lents (chocs) Capacitive injection of the slow transient disturbance (electric surges wave) on the power supply and interconnection lines of the item submitted for testing by the mean of a slow transient generator (surges) 37 Immunité aux perturbations conduites dans la gamme de fréquences de 1 à 150 kHz Conducted disturbances immunity in the frequency range from 1 to 150 kHz Caractéristiques fonctionnelles de l'équipement Functional characteristics of the equipment Injection de la perturbation entre l’entrée et la sortie d’un pôle Phase de l'objet soumis à essai au moyen d'un générateur HF couplé à une résistance, simultanément à l’injection d’un courant différentiel sur le pôle Neutre Injection of disturbance between the input and output of a phase pole of the item submitted for testing by the mean of a HF generator coupled with resistance, with simultaneous injection of a differential current on the neutral pole
-
11-Interrupteurs différentiels; Interrupteurs différentiels avec protection contre les surintensités
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Accréditation n° 1-0145 LAB FORM 37 – Révision 09 – applicable 15 octobre 2022 Page 12/13 Électricité / Équipements électriques (ou électroniques) divers (107) Electricity / Various electrical (or electronic) apparatus (107) N° Nature de l'essai Type of test Objet soumis à essai Object under test Caractéristique mesurée ou recherchée Characteristic measured Principe de la méthode Principle of the method 38 Creux de tension et interruptions Voltage dips and interruptions Interrupteurs différentiels RCCBs Interrupteurs différentiels avec protection contre les surintensités RCBOs Caractéristiques fonctionnelles de l'équipement Functional characteristics of the equipment Succession de chutes de la tension d’alimentation entre 0% et 80% pendant un temps défini Succession of drops in the power supply voltage between 0% and 80% for a defined period of time # Accréditation rendue obligatoire dans le cadre réglementaire français précisé par le texte cité en référence dans le document Cofrac LAB INF 99 disponible sur www.cofrac.fr
0 to 80 %

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

132 Boulevard d'Europe, OBERNAI (67348), 67210, FR

48.45708, 7.49170

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.