Registers refreshed 2026-11-08.See refresh dates
United States

Meyer Gage Company

230 Burnham St., 06074, South Windsor, CT, United States

Visit website
A2LA 3340.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3340.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3340.01) Revised 7/10/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHAMONG HOLDINGS LLC, DBA MEYER GAGE COMPANY 230 Burnham Street South Windsor, CT 06074 Brian Meyer Phone: 860 528 6526 quality@meyergage.com CALIBRATION Valid To: August 31, 2026 Certificate Number: 3340.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1: I. Dimensional Parameter/Equipment Range CMC2 (±) Comments External Diameter – Pins, Plugs, Discs, Trilocks, & Taperlocks .005 in to .035 in >.035 in to 4 in (0.005 to 1.015) in 11 µin 7.9 µin + 1.5 µin/in 29 µin P&W Labmaster™ & gage blocks Aeroel XLS40 laser micrometer Internal Diameter – Plain Ring Gages .040 in to 1 in 1 in to 4 in 4 in to 8.5 in 13 µin 12 in + 0.7 µin/in 7.8 µin + 1.8 µin/in P&W Labmaster™ & master ring gages Thread Wires (1 to 120) TPI (0.2 to 10) Pitch 7.9 µin 0.20 µm P&W Labmaster™ __________________________ 1 This laboratory offers commercial calibration service.
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3340.01) Revised 7/10/2024 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

230 Burnham St., South Windsor, CT, 06074, US

41.83524, -72.55627

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.