Registers refreshed 2026-11-20.See refresh dates
Germany

RS Schwarze Industrieelektronik GmbH EMV-Laboratorium

An der Heller 33, 33758, Schloss Holte-Stukenbrock, Germany

Visit website
DAKKS D-PL-12075-01-00ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
44
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 44 standard numbers and the 34 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR9
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers

Certificate says EN 55012. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2, IEC 55014-2. Probably the same standard; not checked against the EN document.

CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements

Certificate says EN 55016-2-1. Probably the same standard; not checked against the EN document.

CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

Certificate says EN 55016-2-3. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

IEC8
IEC 60204-31
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60947-5-2
IEC 61131-2
IEC 61204-3
IEC 61547Equipment for general lighting purposes - EMC immunity requirements

Certificate says EN 61547. Probably the same standard; not checked against the EN document.

IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 61800-5-2
EN6
EN 12015Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50270
IEC 61326 series6
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-3-1
IEC 61326-3-2

Read from the scope as published by DAKKS. Register refreshed 2026-11-20.

Scope as published by DAKKS

23 lines
DAKKS

ISO/IEC 17025

Active

D-PL-12075-01-00

View scope

Location

An der Heller 33, Schloss Holte-Stukenbrock, 33758, DE

51.88630, 8.62197

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.