What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 32 scope lines.

A2LA certificate 2357.02 · 32 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 2 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Measure (cont) 0 V - 0.000 000 01 V - 0.000 000 1 V - 0.000 001 V - 0.000 01 V - 0.0001 V ± 0.01 V ± 0.1 V ± 1 V ± 10 V ± 100 V ± 120 V ± 500 V ± 1000 V ± 1020 V ± 0.12 V ± 0.121 V ± 1.2 V ± 1.21 V ± 7 V 0.22 µV 0.22 µV 0.22 µV 0.25 µV 1.0 µV 11 µV 19 µV/V 1.1 µV/V 0.4 µV/V 0.3 µV/V 0.6 µV/V 1.5 µV/V 1.5 µV/V 0.9 µV/V 0.9 µV/V 9.2 µV/V 9.0 µV/V 3.2 µV/V 3.0 µV/V 3.0 µV/V Fluke 8588A Fluke 8588A w/ 752A, 732B Fluke 8588A, Fluke 5730A Fluke 8588A DC Voltage – Measure3 0.02 V 0.1 V 0.2 V 1 V 2 V 10 V 20 V 100 V 200 V 37 μV 34 μV 34 μV 44 μV 58 μV 0.3 mV 1.1 mV 3.4 mV 12 mV Keithley DMM7510 Thermocouple Simulation – Measure 0 °C 100 °C 1000 °C 10 000 °C 0 °C ± 1000 °C ± 5000 °C ± 10 000 °C 0 mV 1 mV 10 mV 100 mV 0 mV ± 10 mV ± 50 mV ± 100 mV 0.43 µV 0.45 µV 0.44 µV 0.72 µV 0.08 µV 0.09 µV 0.12 µV 0.23 µV HP 3458A, OPT 002 Fluke 8588A
3-Thermocouple Simulation; DC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 3 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments Thermocouple Simulation – Generate 0 mV 100 mV 1 mV/ °C 0 °C ± 1000 °C ± 5000 °C ± 10 000 °C ± 30 000 °C 0 °C 10 000 °C 0 mV ± 10 mV ± 50 mV ± 100 mV ± 300 mV 0.11 °C 0.29 °C 0.39 µV 0.39 µV 0.39 µV 0.39 µV 0.62 µV Fluke 55XXA Fluke 57xxA DC Current – Generate 0 pA (0.2 to 2) pA (2 to 20) pA (20 to 200) pA (0.2 to 2) nA (2 to 20) nA (20 to 200) nA (1 to 220) μA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 50) A (110 to 500) A (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A 0.9 fA 0.08 % + 0.9 fA 0.1 % + 0.6 fA 0.06 % + 8 fA 0.06 % + 4 fA 0.02 % + 0.8 pA 0.02 % + 0.4 fA 40 μA/A + 6.0 nA 30 μA/A + 6.0 nA 30 μA/A + 40 nA 70 μA/A + 0.30 μA 80 μA/A + 10 μA 0.040 % + 0.50 mA 1.7 % 0.85 % 3.6 µA/A 5.9 µA/A 13 µA/A 39 µA/A 60 µA/A Short / open Fluke 57X0A Keithley 5156 Fluke 57X0A Fluke 57X0A/5725A 5500A/COIL Fluke 8508A, Fluke 742A
See scope document
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 4 of 31 Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Current – Measure 0 pA (0 to 20) pA (20 to 200) pA (0.2 to 2) nA (2 to 20) nA (20 to 200) nA (0 to 100) nA (0.1 to 1) μA (1 to 10) μA (10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 2) A (2 to 11) A (0 to 1) pA (5 to 10) pA (50 to 100) pA (0.5 to 1) nA (5 to 10) nA (50 to 100) nA (0.5 to 1) μA (5 to 10) μA (50 to 100) μA (0.5 to 1) mA (5 to 10) mA (50 to 100) mA 190 µA 329 µA 1.9 mA 3.29 mA 19 mA 32.9 mA 190 mA 329 mA 1.09 A 2.99 A 10.9 A 20 A 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1A 10 fA 0.96 % + 10 fA 1 % + 4 fA 0.13 % + 2 pA 0.2 % + 0.3 pA 0.2 % + 20 fA 3.3 % + 50 pA 0.33 % + 30 pA 0.030 % + 30 pA 40 μA/A + 0.8 nA 40 μA/A + 5 nA 40 μA/A + 50 nA 50 μA/A + 0.6 μA 0.010 % + 10 μA 0.020 % + 30 μA 0.040 % + 0.40 mA 0.25 % + 1.0 fA 0.12 % + 0.1 fA 0.03 % + 0.4 fA 0.03 % + 2 fA 0.01 % + 30 fA 0.01 % + 0.4 pA 0.02 % + 5 pA 0.01 % + 50 pA 0.04 % + 8 nA 0.04 % + 50 nA 0.05 % + 0.5 µA 0.06 % + 5 µA 3.0 nA 3.6 nA 30 nA 35 nA 0.31 µA 0.39 µA 3.1 µA 4.0 µA 15 µA 44 µA 390 µA 790 µA 6.7 µA/A 10 µA/A 12 µA/A 12 µA/A Short / open Keithley 6514 HP 3458A Fluke 8508A Keithley 2002 Keithley 7177 HP 3458A, OPT 002 w/ Fluke 742A-1k w/ Fluke 742A-100 w/ Fluke 742A-10 HP 3458A, OPT 002 w/ Fluke 742A-1 w/ Guildline 9230 w/ Fluke Y5020 HP3458A, OPT 002 w/ 742A-1k, w/ 742A-100, w/ 742A- 10, w/ 742A-1, w/ Guildline 9230
0 to 11 A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 5 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Measure (cont) 0 A -0.000 000 000 1 A -0.000 000 001 A -0.000 000 01 A -0.000 000 1 A -0.000 001 A -0.000 01 A -0.0001 A ±0.000 01 A ±0.0001 A ±0.001 A ±0.01 A ±0.1 A ±1 A ±3.1 A ±10 A ±12 A ±12.1 A ±20 A ±30 A 0.29 µA 0.28 µA 0.28 µA 2.8 µA 0.12 µA 0.60 µA 0.75 µA 4.0 µA 13 µA/A 10 µA/A 7.6 µA/A 23 µA/A 24 µA/A 26 µA/A 35 µA/A 73 µA/A 63 µA/A 63 µA/A 26 µA/A 84 µA/A Fluke 742A-1k w/Fluke 8588A Fluke 742A-1k w/Fluke 8588A Fluke A40B-10mA w/Fluke 8588A Fluke A40B-100mA w/Fluke 8588A Fluke A40B-1A w/Fluke 8588A Fluke A40B-5A w/Fluke 8588A Fluke A40B-20A w/Fluke 8588A Fluke A40B-50A w/Fluke 8588A DC Current – Measure 3 0.1 nA 0.5 nA 1 nA 5 nA 10 nA 50 nA 100 nA 0.5 μA 1 μA 5 μA 10 μA 50 μA 100 μA 0.5 mA 1 mA 5 mA 10 mA 50 mA 100 mA 0.5 A 1 A 0.31 pA 0.86 pA 1.3 pA 5.8 pA 8.3 pA 34 pA 68 pA 86 pA 0.12 nA 3.0 nA 2.4 nA 7.2 nA 13 nA 59 nA 0.11 µA 0.58 µA 0.97 µA 5.5 µA 17 µA 190 µA 0.20 mA Keithley DMM7510 Keithley 5880-SRU
6-DC Resistance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 6 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance – Generate, Fixed Points 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 90 μΩ 0.17 mΩ 0.23 mΩ 0.43 mΩ 1.1 mΩ 2.0 mΩ 9.3 mΩ 0.017 Ω 0.093 Ω 0.17 Ω 1.1 Ω 2.1 Ω 19 Ω 38 Ω 0.44 kΩ 0.95 kΩ 12 kΩ Fluke 57X0A DC Resistance – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 32.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ (1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 31 µΩ/Ω + 0.78 mΩ 24 µΩ/Ω + 1.2 mΩ 22 µΩ/ Ω + 1.1 mΩ 22 µΩ/Ω + 1.5 mΩ 22 µΩ/Ω + 1.6 mΩ 23 µΩ/Ω + 15 mΩ 23 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 0.16 Ω 23 µΩ/Ω + 0.14 Ω 27 µΩ/Ω + 1.4 Ω 25 µΩ/Ω + 2.0 Ω 50 µΩ/Ω + 21 Ω 0.1 mΩ/Ω + 41 Ω 0.2 mΩ/Ω + 1.9 kΩ 0.4 mΩ/Ω + 2.4 kΩ 2.3 mΩ/Ω + 77 kΩ 12 mΩ/Ω + 0.43 MΩ 0.89 µΩ/Ω + 1.1 µΩ 0.54 µΩ/Ω + 4.6 µΩ 1.0 µΩ/Ω 1.0 µΩ/Ω 2.1 µΩ/Ω 2.4 µΩ/Ω 6.7 µΩ/Ω 14 µΩ/Ω 0.12 mΩ/Ω Fluke 55XXA Fluke 742A Fluke 8508A-7000k DC Resistance – Measure (0.1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 20 μΩ/Ω + 0.060 mΩ 10 μΩ/Ω + 0.60 mΩ 10 μΩ/Ω + 0.60 mΩ 10 μΩ/Ω + 5.6 mΩ 10 μΩ/Ω + 0.070 Ω 20 μΩ/Ω + 2.3 Ω 60 μΩ/Ω + 120 Ω 0.060 % + 1.1 kΩ HP 3458A
-
7-DC Resistance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 7 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance – Measure (cont) Fixed Points 0 Ω 0 Ω 2 Ω 10.9 Ω 11.9 Ω 19 Ω 30 Ω 33 Ω 109 Ω 119 Ω 190 Ω 300 Ω 330 Ω 1.09 kΩ 1.19 kΩ 1.9 kΩ 3 kΩ 3.3 kΩ 10.9 kΩ 11.9 kΩ 19 kΩ 30 kΩ 33 kΩ 109 kΩ 119 kΩ 190 kΩ 300 kΩ 330 kΩ 1.09 MΩ 1.19 MΩ 1.9 MΩ 3 M Ω 3.3 MΩ 10.9 MΩ 11.9 MΩ 19 MΩ 30 MΩ 33 MΩ 109 MΩ 119 MΩ 290 MΩ 400 MΩ 640 MΩ 1090 MΩ 53 μΩ 53 μΩ 82 μΩ 0.61 mΩ 0.62 mΩ 0.86 mΩ 0.95 mΩ 0.97 mΩ 2.1 mΩ 5.3 mΩ 5.6 mΩ 6 mΩ 6 mΩ 0.015 Ω 0.015 Ω 0.025 Ω 0.032 Ω 0.077 Ω 0.15 Ω 0.53 Ω 0.55 Ω 0.59 Ω 0.92 Ω 1.5 Ω 1.0 Ω 1.1 Ω 0.93 Ω 0.92 Ω 3 Ω 14 Ω 35 Ω 23 Ω 0.15 kΩ 0.17 kΩ 0.13 kΩ 1.3 kΩ 0.52 kΩ 0.53 kΩ 3.3 kΩ 7.1 kΩ 21 kΩ 0.31 MΩ 1.9 MΩ 0.34 MΩ 4 wire short HP 3458A HP 3458 w/ 742A- 1M w/ 742A-10M HP 3458A w/ Guildline 9334A- 100M
See scope document
8-DC Resistance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 8 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance – Measure (cont) Fixed Points (1 to 1.9) Ω (1.9 to 10) Ω (10 to 19) Ω (19 to 100) Ω (100 to 190) Ω 190 Ω to 1 kΩ (1 to 1.9) kΩ (1.9 to 10) kΩ (10 to 19) kΩ (19 to 100) kΩ (100 to 190) kΩ 190 kΩ to 1 MΩ (1 to 1.9) MΩ (1.9 to 10) MΩ (10 to 19) MΩ (19 to 100) MΩ 0 Ω 1 Ω 10 Ω 12.1 Ω 100 Ω 121 Ω 1 kΩ 1.21 kΩ 1.90 kΩ 3.00 kΩ 5.00 kΩ 10.0 kΩ 11.9 kΩ 12.1 kΩ 100 kΩ 121 kΩ 1.00 MΩ 1.21 MΩ 10.0 MΩ 12.1 MΩ 100 MΩ 121 MΩ 300 MΩ 400 MΩ 640 MΩ 1 GΩ 21 μΩ 1.3 μΩ/Ω + 16 μΩ 12 μΩ/Ω + 2 μΩ 0.74 μΩ/Ω + 220 μΩ 5.3 μΩ/Ω 0.37 μΩ/Ω + 930 μΩ 5.3 μΩ/Ω 0.12 μΩ/Ω + 9.8 mΩ 10 μΩ/Ω 0.10 μΩ/Ω + 0.19 Ω 12 μΩ/Ω + 0.020 Ω 0.60 μΩ/Ω + 2.2 Ω 13 μΩ/Ω + 0.3 Ω 80 μΩ/Ω 56 μΩ/Ω + 240 Ω 90 μΩ/Ω 24 μΩ 13 μΩ/Ω 5.6 μΩ/Ω 5.6 μΩ/Ω 4.3 μΩ/Ω 4.3 μΩ/Ω 6.7 μΩ/Ω 6.7 μΩ/Ω 7.3 μΩ/Ω 7.3 μΩ/Ω 7.1 μΩ/Ω 6.8 μΩ/Ω 6.9 μΩ/Ω 6.9 μΩ/Ω 5.4 μΩ/Ω 7.7 μΩ/Ω 4.9 μΩ/Ω 8.5 μΩ/Ω 5.2 μΩ/Ω 5.2 μΩ/Ω 77 μΩ/Ω 120 μΩ/Ω 510 μΩ/Ω 420 μΩ/Ω 520 μΩ/Ω 620 μΩ/Ω Fluke 8508A w/ 742A w/ Guildline 9334A-100M 742A-100 w/Fluke 8588A w/57xxA 742A-1k w/Fluke 8588A w/57xxA 742A-10k w/Fluke 8588A w/57xxA 742A-100k w/Fluke 8588A w/57xxA 742A-1M w/Fluke 8588A w/57xxA 742A-10M w/Fluke 8588A w/57xxA Fluke SL984 w/Fluke 8588A w/57xxA
-
9-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 9 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (0.2 to 2.2) mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.010 % + 5.0 μV 0.020 % + 4.0 μV 60 μV/V + 4.0 μV 0.020 % + 4.0 μV 0.030 % + 6.0 μV 0.11 % + 10 μV 0.11 % + 20 μV 0.22 % + 20 μV 0.060 % + 4.0 μV 0.040 % + 4.0 μV 0.030 % + 4.0 μV 0.020 % + 4.0 μV 0.080 % + 5.0 μV 0.14 % + 10 μV 0.14 % + 20 μV 0.27 % + 20 μV 0.030 % + 10 μV 0.020 % + 10 μV 90 μV/V + 7.0 μV 0.020 % + 7.0 μV 0.050 % + 20 μV 0.090 % + 20 μV 0.13 % + 30 μV 0.26 % + 50 μV 0.030 % + 40 μV 0.020 % + 40 μV 90 μV/V + 20 μV 70 μV/V + 10 μV 0.010 % + 30 μV 0.040 % + 80 μV 0.10 % + 200 μV 0.15 % + 400 μV Fluke 57X0A
See scope document
10-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 10 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (cont) (2.2 to 22) V (22 to 220) V (220 to 700) V (700 1100) V (0.1 to 1) V (1 to 10) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (20 to 55) Hz 55 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz (20 to 55) Hz 55 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz 0.030 % + 0.40 mV 0.020 % + 0.40 mV 90 μV/V + 0.20 mV 70 μV/V + 90 μV 0.010 % + 0.20 mV 0.030 % + 0.60 mV 0.090 % + 0.90 mV 0.14 % + 3.1 mV 0.030 % + 3.5 mV 0.020 % + 3.8 mV 90 μV/V + 1.5 mV 80 μV/V + 0.90 mV 0.14 % + 1.6 mV 0.090 % + 15 mV 90 μV/V + 1.6 mV 80 μV/V 0.010 % + 0.30 mV 0.020 % + 3.3 mV 0.060 % + 10 mV 29 µV/V + 1 µV 23 µV/V + 2 µV 24 µV/V + 1 µV 30 µV/V 36 µV/V + 4 µV 58 µV/V + 10 µV 74 µV/V + 9 µV 31 µV/V 26 µV/V 31 µV/V 30 µV/V 57 µV/V 0.10 mV/V 0.17 mV/V 2.9 mV/V 4.5 mV/V Fluke 57X0A Fluke 57X0A/5725A Fluke 792A, Fluke 5790A/B, Fluke 5730A Fluke 792A, Fluke 5790A/B, Fluke 5730A
See scope document
11-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 11 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (cont) (10 to 100) V (100 to 500) V (500 to 1000) V (20 to 55) Hz 55 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz 50 Hz to 1 kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (1 to 30) kHz 39 µV/V 25 µV/V + 11 µV 29 µV/V + 11 µV 30 µV/V 72 µV 0.11 mV/V 0.10 mV/V 39 µV/V 38 µV/V 43 µV/V 73 µV/V 2 µV/V + 17 mV Fluke 792A, Fluke 5790A/B, Fluke 5730A AC Voltage – Generate Squarewave (Vp-p) (24 to 26) mVp-p (72 to 78) mVp-p (2.4 to 2.6) Vp-p (4.8 to 5.2) Vp-p 1 kHz 0.067 mV 0.095 mV 2.5 mV 7.6 mV Wavetek 9500, Fluke 9500/B w/ 9530 AC Voltage – Measure 220 μV to 10 mV (10 to 100) mV (0.1 to 1) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.030 % + 4.0 μV 0.020 % + 3.0 μV 0.030 % + 3.0 μV 0.10 % + 3.0 μV 0.60 % + 2.0 μV 4.6 % + 3.0 μV 70 μV/V + 50 μV 0.010 % + 9.0 μV 0.010 % + 9.0 μV 0.030 % + 8.0 μV 0.090 % + 5.0 μV 0.35 % + 10 μV 1.2 % + 30 μV 70 μV/V + 60 μV 70 μV/V + 40 μV 0.020 % + 40 μV 0.030 % + 40 μV 0.090 % + 30 μV 0.35 % + 100 μV 1.2 % + 300 μV HP 3458A
-
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 12 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) (1 to 10) V (10 to 100) V (100 to 700) V (700 to 1000) V 3 mV 30 mV 33 mV 300 mV 0.33 V 3 V 3 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz 40 Hz to 10 kHz (10 to 30) kHz (50 to 60) Hz 10 Hz 50 Hz 60 Hz to 20 kHz 50 kHz 100 kHz 450 kHz 1 kHz 10 Hz 50 Hz 60 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 500 kHz 1 kHz 10 Hz 50 Hz 60 Hz 1 kHz 10 kHz 20 kHz 50 kHz 100 kHz 450 kHz 70 μV/V + 0.70 mV 60 μV/V + 0.60 mV 0.010 % + 0.60 mV 0.030 % + 0.50 mV 0.090 % + 0.40 mV 0.35 % + 1.3 mV 1.2 % + 5.6 mV 0.020 % + 5.7 mV 0.020 % + 3.8 mV 0.020 % + 3.8 mV 0.040 % + 3.4 mV 0.14 % + 3.3 mV 0.050 % + 30 mV 0.030 % + 24 mV 0.020 % + 57 mV 2 µV 9.1 µV 3.7 µV 3.6 µV 6.1 µV 0.11 mV 30 µV 3.9 µV 68 µV 20 µV 12 µV 18 µV 19 µV 12 µV 18 µV 28 µV 0.11 mV 18 µV 0.93 mV 0.14 mV 0.12 mV 0.10 mV 0.19 mV 85 µV 0.15 mV 0.25 mV 1.2 mV HP 3458A Fluke 8508A Fluke 5790B
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 13 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) 3.3 V 30 V 33 V 300 V 330 V 1000 V 10 mV 300 mV 3 V 5 V 1 kHz 10 Hz 50 Hz 60 Hz (1 to 10) kHz 20 kHz 50 kHz 90 kHz 1 kHz 50 Hz 60 Hz (1 to 18) kHz 50 kHz 80 kHz 1 kHz (50 to 60) Hz 1 kHz 5 kHz 8 kHz 50 Hz 60 Hz 1 kHz 5 kHz 10 kHz 30 kHz 10 Hz 45 Hz 50 Hz 60 Hz 1 kHz 5 kHz 10 kHz 30 kHz 10 Hz 45 Hz 50 Hz 60 Hz 1 kHz 5 kHz 10 kHz 30 kHz 10 Hz 45 Hz 50 Hz 60 Hz 1 kHz 5 kHz 10 kHz 0.35 mV 6.1 mV 1.0 mV 1.1 mV 1.0 mV 1.1 mV 1.8 mV 2.9 mV 2.5 mV 14 mV 15 mV 14 mV 40 mV 0.15 V 16 mV 44 mV 48 mV 43 mV 44 mV 12 µV 2.2 µV 2.9 µV 3.4 µV 2.8 µV 2.6 µV 64 µV 12 µV 15 µV 12 µV 18 µV 12 µV 19 µV 18 µV 0.93 mV 0.11 mV 0.15 mV 0.14 mV 0.11 mV 0.10 mV 0.20 mV 0.16 mV 50 mV 0.35 mV 0.31 mV 0.28 mV 0.22 mV 0.19 mV 1.1 mV Fluke 5790B
14-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 14 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) (2 to 20) mV (20 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 10 Hz 50 Hz 60 Hz 400 Hz to 20kHz 50 kHz 100 kHz 300 kHz 1 MHz 10 Hz 50 Hz 60 Hz 400 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 1 MHz 10 Hz 50 Hz 60 Hz 400 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 1 MHz 10 Hz 50 Hz 60 Hz 400 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 1 MHz 10 Hz 50 Hz 60 Hz 400 Hz 1 kHz 20 kHz 50 kHz 100 kHz 50 Hz 60 Hz 400 Hz 1 kHz 120 µV/V + 3.5 µV 61 µV/V + 1.7 µV 67 µV/V + 1.6 µV 61 µV/V + 1.6 µV 120 µV/V + 2.6 µV 180 µV/V + 3.5 µV 520 µV/V + 5.7 µV 1200 µV/V + 10 µV 170 µV/V + 2.4 µV 45 µV/V + 2.0 µV 31 µV/V + 2.3 µV 27 µV/V + 2.4 µV 26 µV/V + 2.4 µV 27 µV/V + 2.3 µV 45 µV/V + 4.0 µV 120 µV/V + 4.6 µV 160 µV/V + 13 µV 760 µV/V + 19 µV 800 µV/V 41 µV/V + 2.9 µV 21 µV/V + 4.2 µV 19 µV/V + 4.0 µV 17 µV/V + 5.0 µV 18 µV/V + 4.1 µV 34 µV/V + 6.2 µV 51 µV/V + 18 µV 120 µV/V + 21 µV 740 µV/V + 22 µV 800 µV/V 22 µV/V + 40 µV 32 µV/V 24 µV/V 24 µV/V 23 µV/V 39 µV/V 65 µV/V 150 µV/V 950 µV/V 1100 µV/V + 14 000 µV 41 µV/V 34 µV/V 27 µV/V 27 µV/V 23 µV/V 55 µV/V 80 µV/V 39 µV/V + 380 µV 57 µV/V 34 µV/V 34 µV/V Fluke 5790B
See scope document
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 15 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) 0.001 V 0.01 V 0.0121 V 0.1 V 0.12 V 0.121 V 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 45 Hz 65 Hz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 1400 µV/V 1400 µV/V 1400 µV/V 1300 µV/V 1300 µV/V 1300 µV/V 2200 µV/V 2900 µV/V 4900 µV/V 8100 µV/V 42 µV/V 44 µV/V 47 µV/V 190 µV/V 190 µV/V 190 µV/V 320 µV/V 430 µV/V 940 µV/V 1300 µV/V 42 µV/V 44 µV/V 47 µV/V 170 µV/V 170 µV/V 170 µV/V 290 µV/V 400 µV/V 880 µV/V 1200 µV/V 32 µV/V 34 µV/V 37 µV/V 41 µV/V 41 µV/V 41 µV/V 69 µV/V 140 µV/V 220 µV/V 360 µV/V 39 µV/V 39 µV/V 32 µV/V 34 µV/V 37 µV/V 40 µV/V 39 µV/V 39 µV/V 66 µV/V 140 µV/V 220 µV/V 350 µV/V Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 5790B Fluke 8588A 8 Fluke 5790B
16-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 16 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) 1 V 1.2 V 1.21 V 3.3 V 5 V 10 V 12.1 V 3 Hz 5 Hz 10 Hz 40 Hz 40.01 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 45 Hz 400 Hz 1 kHz 5 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 10 kHz 45 Hz 400 Hz 1 kHz 5 kHz 10 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 500 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 27 µV/V 27 µV/V 28 µV/V 19 µV/V 19 µV/V 19 µV/V 19 µV/V 36 µV/V 55 µV/V 130 µV/V 280 µV/V 19 µV/V 21 µV/V 19 µV/V 19 µV/V 27 µV/V 27 µV/V 28 µV/V 25 µV/V 19 µV/V 19 µV/V 36 µV/V 55 µV/V 120 µV/V 200 µV/V 37 µV/V 19 µV/V 19 µV/V 19 µV/V 19 µV/V 19 µV/V 27 µV/V 27 µV/V 28 µV/V 22 µV/V 21 µV/V 21 µV/V 37 µV/V 63 µV/V 160 µV/V 310 µV/V 27 µV/V 27 µV/V 28 µV/V 24 µV/V 21 µV/V 21 µV/V 37 µV/V 63 µV/V 150 µV/V Fluke 8588A 8 Fluke 5790B Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B
-
17-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 17 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont) 100 V 121 V 330 V 331 V 1000 V 1020 V 3 Hz 5 Hz 10 Hz 40 Hz 40.01 Hz 1 kHz 20 kHz 50 kHz 100 kHz 300 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 10 kHz 10.01 kHz 20 kHz 50 kHz 100 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 20 kHz 50 kHz 100 kHz 3 Hz 5 Hz 10 Hz 40 Hz 1 kHz 10 kHz 40 Hz 1 kHz 10 kHz 27 µV/V 27 µV/V 28 µV/V 24 µV/V 24 µV/V 24 µV/V 24 µV/V 54 µV/V 76 µV/V 160 µV/V 27 µV/V 27 µV/V 28 µV/V 29 µV/V 24 µV/V 24 µV/V 24 µV/V 24 µV/V 54 µV/V 76 µV/V 27 µV/V 27 µV/V 28 µV/V 33 µV/V 32 µV/V 32 µV/V 100 µV/V 390 µV/V 26 µV/V 26 µV/V 27 µV/V 32 µV/V 32 µV/V 32 µV/V 29 µV/V 30 µV/V 30 µV/V Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 8588A 8 Fluke 5790B Fluke 5790B
See scope document
18-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 18 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (0 to 0.22) mA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (11 to 500) A (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 65) Hz (0.3 to 1) kHz (1 to 3) kHz (3 to 5) kHz (5 to 10) kHz (0.3 to 1) kHz (1 to 3) kHz (3 to 5) kHz (5 to 10) kHz (0.3 to 1) kHz (1 to 3) kHz (3 to 5) kHz (5 to 10) kHz (0.3 to 1) kHz (1 to 3) kHz (3 to 5) kHz (5 to 10) kHz 0.020 % + 20 nA 0.020 % + 20 nA 0.010 % + 20 nA 0.020 % + 20 nA 1.0 % + 60 nA 0.020 % + 40 nA 0.020 % + 40 nA 0.020 % + 30 nA 0.020 % + 100 nA 0.10 % + 600 nA 0.020 % + 200 nA 0.020 % + 200 nA 0.020 % + 100 nA 0.020 % + 300 nA 0.090 % + 3.0 μA 0.020 % + 2.0 μA 0.020 % + 4.0 μA 0.020 % + 3.0 μA 0.020 % + 3.0 μA 0.10 % + 10 μA 0.030 % + 30 μA 0.050 % + 80 μA 0.72 % + 0.20 mA 0.05 % + 0.20 mA 0.10 % + 0.30 mA 0.36 % + 1.3 mA 1.5 % 0.12 mA/A + 5.6 nA 0.13 mA/A + 0.11 µA 0.13 mA/A 0.12 mA/A 18 µA/A + 0.11 µA 18 µA/A + 0.11 µA 20 µA/A + 0.11 µA 20 µA/A + 0.11 µA 39 µA/A 40 µA/A 41 µA/A 41 µA/A 60 µA/A 60 µA/A 42 µA/A 42 µA/A Fluke 57X0A Fluke 57X0A/5725A Fluke 5500A/COIL Metal film register Fluke 5790A/B Fluke 5730A Shunt: A40B-10 mA A40B-1 A A40B-20 A
See scope document
19-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 19 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (cont) (1 to 10) A (0.3 to 1) kHz (1 to 3) kHz (3 to 5) kHz (5 to 10) kHz 82 µA/A 0.12 mA/A 0.21 mA/A 0.64 mA/A Shunt: A40B-10 mA A40B-1 A A40B-20 A AC Current – Measure (10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 2) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 1) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.46 % + 0.040 μA 0.17 % + 0.040 μA 0.070 % + 0.040 μA 0.070 % + 0.040 μA 0.46 % + 0.30 μA 0.17 % + 0.30 μA 0.060 % + 0.40 μA 0.030 % + 0.40 μA 0.46 % + 3.0 μA 0.16 % + 4.0 μA 0.050 % + 5.0 μA 0.020 % + 5.0 μA 0.46 % + 30 μA 0.16 % + 40 μA 0.060 % + 40 μA 0.020 % + 40 μA 0.45 % + 400 μA 0.15 % + 700 μA 0.060 % + 800 μA 0.090 % + 700 μA 0.060 % + 0.20 mA 0.080 % + 0.20 mA HP 3458A
-
20-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 20 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (cont) (2 to 11) A 33 µA 329 µA 0.33 mA 3.29 mA 3.3 mA 32.9 mA 33 mA 329 mA 0.33 A 10 Hz to 2 kHz (2 to 10) kHz (1 to 10) kHz 10 Hz 45 Hz 50 Hz 60 Hz to 30 kHz (1 to 5) kHz 10 Hz 45 Hz 50 Hz 60 Hz to 10 kHz 30 kHz (1 to 5) kHz 10 Hz 45 Hz to 10 kHz 30 kHz 1 kHz 5 kHz 30 kHz 10 Hz 45 Hz (50 to 60) Hz (1 to 10) kHz 30 kHz 1 kHz (5 to 10) kHz 0.080 % + 2.0 mA 0.26 % + 2.0 mA 0.036 µA 0.13 µA 0.11 µA 0.16 µA 0.11 µA 0.13 µA 0.97 µA 0.64 µA 0.65 µA 0.64 µA 0.66 µA 0.92 µA 9.5 µA 6.2 µA 6.8 µA 9.1 µA 9.2 µA 9.3 µA 0.11 mA 0.069 mA 0.070 mA 0.069 mA 0.087 mA 0.17 mA 0.16 mA Fluke 8508A Fluke 5522A, 5790B w/ 1 kΩ metal film resistor
-
21-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 21 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (cont) 2.99 A 3.3 A 10 A 20 A 190 µA to 1.9 mA (1.9 to 19) mA (19 to 190) mA 190 mA to 1.9 A 10 µA 100 µA 50 Hz to 5 kHz 500 Hz 5 kHz (50 to 60) Hz 1 kHz 5 kHz 50 Hz to 1 kHz 5 kHz 50 Hz 60 Hz 400 Hz to 10 kHz 50 Hz 60 Hz 400 Hz to 5 kHz 10 kHz 50 Hz 60 Hz 400 Hz to 5 kHz 10 kHz 50 Hz to 60 Hz 400 Hz to 1 kHz 5 kHz 10 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 0.0017 A 0.0031 A 0.0032 A 0.0080 A 0.0083 A 0.011 A 0.030 A 0.034 A 130 µA/A + 0.0013 µA 130 µA/A + 0.0023 µA 110 µA/A + 0.0051 µA 130 µA/A 130 µA/A 120 µA/A 110 µA/A + 0.010 µA 120 µA/A + 0.20 µA 130 µA/A + 0.11 µA 120 µA/A + 0.20 µA 120 µA/A + 0.20 µA 160 µA/A 160 µA/A 190 µA/A 530 µA/A 86 µA/A 270 µA/A 230 µA/A 230 µA/A 230 µA/A 530 µA/A 53 µA/A 57 µA/A 63 µA/A 63 µA/A 63 µA/A 67 µA/A 110 µA/A Fluke 5790B, AC shunts Fluke A40B- 1mA w/Fluke 5790B w/Fluke 8588A
See scope document
22-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 22 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (cont) 121 µA 1 mA 1.21 mA 10 mA 12.1 mA 100 mA 121 mA 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 53 µA/A 60 µA/A 62 µA/A 62 µA/A 64 µA/A 91 µA/A 50 µA/A 51 µA/A 46 µA/A 49 µA/A 49 µA/A 51 µA/A 67 µA/A 41 µA/A 49 µA/A 52 µA/A 52 µA/A 54 µA/A 82 µA/A 37 µA/A 38 µA/A 31 µA/A 35 µA/A 36 µA/A 39 µA/A 56 µA/A 38 µA/A 32 µA/A 36 µA/A 36 µA/A 39 µA/A 56 µA/A 37 µA/A 38 µA/A 31 µA/A 35 µA/A 36 µA/A 39 µA/A 56 µA/A 38 µA/A 32 µA/A 35 µA/A 36 µA/A 39 µA/A 57 µA/A Fluke A40B- 1mA w/Fluke 5790B w/Fluke 8588A Fluke A40B- 10mA w/Fluke 5790B w/Fluke 8588A Fluke A40B- 100mA w/Fluke 5790B w/Fluke 8588A
-
23-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 23 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (cont) 1 A 1.21 A 3.1 A 3.11 A 10 A 12.1 A 20 A 30 A 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 30 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 3 Hz 45 Hz 1 kHz 5 kHz 10 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 10 kHz 3 Hz 45 Hz 1 kHz 5 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 3 Hz 10 Hz 45 Hz 1 kHz 5 kHz 40 µA/A 40 µA/A 34 µA/A 36 µA/A 41 µA/A 67 µA/A 83 µA/A 42 µA/A 41 µA/A 43 µA/A 47 µA/A 71 µA/A 47 µA/A 48 µA/A 47 µA/A 49 µA/A 59 µA/A 75 µA/A 47 µA/A 48 µA/A 53 µA/A 59 µA/A 75 µA/A 82 µA/A 82 µA/A 82 µA/A 85 µA/A 100 µA/A 150 µA/A 74 µA/A 74 µA/A 78 µA/A 94 µA/A 47 µA/A 48 µA/A 47 µA/A 66 µA/A 160 µA/A 93 µA/A 94 µA/A 93 µA/A 110 µA/A 180 µA/A Fluke A40B-1A w/Fluke 5790B w/Fluke 8588A Fluke A40B-5A w/Fluke 5790B w/Fluke 8588A Fluke A40B-20A w/Fluke 5790B w/Fluke 8588A Fluke A40B-50A w/Fluke 5790B w/Fluke 8588A
-
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 24 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage Phase – Measure 3 V / (0 ± 10) ° 3 V / (60 ± 10) ° 3 V / (90 ± 10) °° 30 V / (90 ± 10) ° 50 V / (90 ± 10) ° 10V, 5V / (0 ± 10) ° 10V, 5V / (30 ± 10) ° 10V, 5V / (45 ± 10) ° 10V, 5V / (60 ± 10) ° 10V, 5V / (90 ± 10) ° 10V, 5V / (180 ± 10) ° 10V, 5V / (270 ± 10) ° 65 Hz to 1 kHz 5 kHz 10 kHz 30 kHz 60 Hz 400 Hz 1 kHz 5 kHz 10 kHz 30 kHz (60 to 65) Hz 400 Hz 1 kHz 5 kHz 10 kHz 30 kHz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 0.022 ° 0.048 ° 0.056 ° 0.063 ° 0.026 ° 0.027 ° 0.025 ° 0.048 ° 0.054 ° 0.063 ° 0.022 ° 0.027 ° 0.027 ° 0.048 ° 0.058 ° 0.067 ° 0.022 ° 0.035 ° 0.023 ° 0.023 ° 0.023 ° 0.023 ° 0.023 ° 0.023 ° 0.023 ° Clarke-Hess 6000A AC Current Phase – Measure 300 mA / (0 ± 10) ° 2 A / (0 ± 10) ° 5 A / (0 ± 10) ° 300 mA / (60 ± 10) ° 2 A / (60 ± 10) ° 20 A / (60 ± 10) ° 20 A / (60 ± 10) ° 300 mA / (90 ± 10) ° 2 A / (90 ± 10) ° 20 A / (90 ± 10) ° 20 A / (90 ± 10) ° 65 Hz 1 kHz 30 kHz 65 Hz 65 Hz 400 Hz 65 Hz 0.025 ° 0.027 ° 0.066 ° 0.024 ° 0.030 ° 0.035 ° 0.027 ° 0.026 ° 0.025 ° 0.032 ° 0.031 ° 0.025 ° 0.041 ° 0.041 ° For 300 mA & 2A; A40, 6000 A For 5 A & 20 A; Y5020, 6000 A
25-AC Current Phase; AC Capacitance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 25 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current Phase – Measure (cont) 10 V, 0.1 A/ (0 ± 10) ° 10 V, 0.1 A / (30 ± 10) ° 10 V, 0.1 A / (45 ± 10) ° 10 V, 0.1 A / (60 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 0.1 A / (180 ± 10) ° 10 V, 0.1 A / (270 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 0.1 A / (90 ± 10) ° 10 V, 3.11 A / (0 ± 10) ° 10 V, 3.11 A / (0 ± 10) ° 1 V, 12.1 A / (180 ± 10) ° 10 V, 12.1 A / (30 ± 10) ° 1.2 V, 20 A / (0 ± 10) ° 10 V, 20 A / (90 ± 10) ° 250 V, 0.1 A / (90 ± 10) ° 250 V, 0.1 A / (0 ± 10) ° 250 V, 0.1 A / (45 ± 10) ° 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 65 Hz 400 Hz 1000 Hz 5000 Hz 10 000 Hz 30 000 Hz 65 Hz 400 Hz 65 Hz 65 Hz 65 Hz 400 Hz 65 Hz 10 000 Hz 30 000 Hz 0.027 ° 0.027 ° 0.027 ° 0.027 ° 0.027 ° 0.027 ° 0.027 ° 0.034 ° 0.036 ° 0.049 ° 0.064 ° 0.079 ° 0.027 ° 0.034 ° 0.027 ° 0.027 ° 0.027 ° 0.034 ° 0.027 ° 0.064 ° 0.079 ° Clarke-Hess 6000A w/A40B AC Capacitance – Measure 0.22 nF 0.35 nF 0.48 nF 0.6 nF 1 nF 2 nF 7 nF 10.9 nF 20 nF 70 nF 109 nF 200 nF 300 nF 0.7 µF 1.09 µF 2 µF 3 µF 7 µF 10.9 µF 20 µF 30 µF 70 µF 109 µF 5 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 1 kHz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 100 Hz 50 Hz 50 Hz 0.46 pF 0.39 pF 0.46 pF 0.48 pF 0.63 pF 1.2 pF 3.8 pF 6.6 pF 11 pF 39 pF 66 pF 0.11 nF 0.17 nF 0.40 nF 0.78 nF 1.2 nF 1.7 nF 3.9 nF 6.9 nF 12 nF 16 nF 41 nF 68 nF Hioki IM3533
-
26-capacitance; inductance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 26 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments AC Capacitance – Measure (cont) 0.2 nF 1 nF 1.21 nF 10 nF 12.1 nF 20 nF 30 nF 50 nF 100 nF 120 nF 121 nF 1 µF 1.21 µF 10 µF 12.1 µF 100 µF 121 µF 1000 Hz 1000 Hz 1000 Hz 1000 Hz 610 Hz 610 Hz 610 Hz 610 Hz 610 Hz 610 Hz 100 Hz 100 Hz 80 Hz 80 Hz 20 Hz 20 Hz 5 Hz 1500 µF/F 610 µF/F 610 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F 500 µF/F Hioki IM3533 AC Inductance – Measure 15 µH 100 µH 121 µH 1 mH 1.21 mH 2 mH 3 mH 5 mH 10 mH 12 mH 12.1 mH 100 mH 121 mH 1 H 1.21 H 10 H 12.1 H 100 H 1 kHz 1 kHz 1 kHz 1 kHz 110 Hz 110 Hz 110 Hz 110 Hz 110 Hz 110 Hz 100 Hz 100 Hz 10 Hz 10 Hz 3 Hz 3 Hz 2 Hz 2 Hz 1500 µH/H 760 µH/H 760 µH/H 550 µH/H 550 µH/H 550 µH/H 550 µH/H 550 µH/H 550 µH/H 550 µH/H 550 µH/H 510 µH/H 550 µH/H 510 µH/H 550 µH/H 500 µH/H 500 µH/H 500 µH/H Hioki IM3533 4 Terminal Parallel Capacitance – Generate 3 1 pF 10 pF 100 pF 1000 pF 1 MHz 100 kHz 1 MHz 10 kHz 100 kHz 1 MHz 10 kHz 100 kHz 1 MHz 12 fF 0.014 pF 0.012 pF 0.18 pF 0.038 pF 0.042 pF 0.88 pF 0.25 pF 0.82 pF 5880-SRU set of standard capacitors from 1 pF to 1000 pF
-
27-DC Capacitance; Oscilloscopes; DC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 27 of 31 Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Capacitance – Measure 200 µF 300 µF 1 mF 3 mF 10 mF 30 mF 50 mF 100 mF 1 mF 1.21mF 10 mF 12.1mF 100 mF 0.098 µF 0.11 µF 0.24 µF 0.45 µF 1.1 µF 3.4 µF 5 µF 9 µF 160 µF/F 140 µF/F 130 µF/F 130 µF/F 140 µF/F HP 3458A, 5522A Fluke 5730A w/8588A Oscilloscopes – Short Circuit Output Amplitude – DC Volts: 50 Ω & 1 MΩ Load 1 MΩ Load Amplitude - Sinewave, Vp-p; 50 Ω Load RMS Noise – Measure DC Voltage – Generate DC Voltage – Measure 50 Ω 1 MΩ 0 V (1 to 100) mV 100 mV to 1.0 V (1.0 to 5.56) V (5 to 200) V 4.4 mV to 5.6 V 1 Hz to 550 MHz 4.4 mV to 3.4 V 550 MHz to 2.5 GHz 4.4 mV to 2.2 V (2.5 to 3.2) GHz 20 MHz BW 175 MHz BW (0.2 to 10) GHz BW (48 to 52) mV (477 to 523) mV (0.97 to 1.03) V (1.9 to 2.1) V (4.8 to 5.2) V (9.6 to 10.4) V (0.03 to 0.25) V (1 to 1.5) V (0.03 to 0.7) V (2.5 to 3.3) V 15 μV 0.050 % + 26 μV 0.022 % + 65 μV 0.026 % + 50 μV 0.030 % 0.033 V/V 0.063 V/V 0.11 V/V 0.18 µV 2.2 µV 1.1 µV 0.11 mV 0.52 mV 0.8 mV 1.9 mV 5.8 mV 8.9 mV 0.12 V 0.13 V 0.17 V 0.17 V Wavetek 9500, Fluke 9500B Wavetek 9500, Fluke 9500B Wavetek/Fluke 9530 Tektronix MSO series Fluke 9500B Wavetek Tektronix MSO series
-
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 28 of 31 Parameter/Equipment Range CMC2, 4 (±) Comments Oscilloscopes – (cont) Leveled Sinewave Flatness 50 Ω Load 50 kHz to 10 MHz Reference, V p-p 1 Hz to 100 MHz (100 to 550) MHz 550 MHz to 1.1 GHz (1.1 to 2.5) GHz (2.5 to 3.2) GHz 1.0 GHz 2.0 GHz 2.5 GHz (3.2 to 8.0) GHz (3.2 to 8.0) GHz (8.0 to 12.5) GHz (8.0 to 12.5) GHz (12.5 to 16) GHz (12.5 to 16) GHz (16 to 18) GHz (16 to 18) GHz (18 to 20) GHz (18 to 20) GHz (20 to 23) GHz (20 to 23) GHz (23 to 25) GHz (23 to 25) GHz (25 to 33) GHz (25 to 33) GHz Time Marker 3 Rise Time – Measuring Equipment Rise Time – Measure 4.4 mV to 5.6 V 4.4 mV to 5.6 V 4.4 mV to 3.4 V 4.4 mV to 3.4 V 4.4 mV to 2.2 V Up to 800 mV Up to 800 mV Up to 800 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 300 mV > 300 mV Up to 120 mV > 120 mV 1 ns to 100 ms (14 ± 3) ps 17.5 ps to 10 ns 0.22 dB 0.27 dB 0.37 dB 0.47 dB 0.48 dB 0.22 dB 0.27 dB 0.34 dB 0.30 dB 0.31 dB 0.37 dB 0.38 dB 0.46 dB 0.42 dB 0.52 dB 0.42 dB 0.56 dB 0.40 dB 0.55 dB 0.58 dB 0.57 dB 0.61 dB 0.87 dB 0.84 dB 0.20 μs/s + 3 ps 4.7 ps 5.6 ps Wavetek 9500, Fluke 9500B w/ 9530 head Synthesized signal generator w/ power sensor & power meter Wavetek 9500, Fluke 9500B TDS 8200/80E04
29

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 29 of 31 Parameter/Equipment Range CMC2, 4, 7 (±) Comments Input Resistance – Measure 50 Ω 75 Ω 1 MΩ 0.045 Ω 0.13 Ω 0.41 kΩ Fluke 9500B/9530 Pulse Characterization – Measure, Fixed Points 3 Overshoot Preshoot Pulse Width RMS Jitter Slew Rate 0.5 V 2 V 5 V 20 V 5 V 20 V 500 ns 0 s 0.5 V/ns 0.2 V/ns 0.50 % 0.53 % 0.46 % 0.45 % 0.46 % 0.48 % 0.11 ns 0.017 ns 0.0061 V/ns 0.0025 V/ns Oscilloscope Tektronix MSO44 II. Fluid Quantities Parameter/Equipment Range CMC2, 6, 7 (±) Comments Gas Flow – Measuring Equipment (1 to 10) SCCM (20 to 200) SCCM (0.1 to 1) SLM (0.5 to 5) SLM 0.24 % 0.37 % 0.24 % 0.33 % MOLBLOC 1E1 MOLBLOC 2E2 MOLBLOC 1E3 MOLBLOC 5E3 w/ MOLBOX 1 III. Mechanical Parameter/Equipment Range CMC 2, 6, 7 (±) Comments Torque – Measuring Equipment (3.5 to 35) N∙cm (35 to 141) N∙cm (1.41 to 5.65) N∙m (5.65 to 45.2) N∙m (45.2 to 113) N∙m (113 to 339) N∙m (339 to 813.6) N∙m 0.32 % 0.34 % 0.34 % 0.32 % 0.35 % 0.30 % 0.33 % Snap-on TTC4 Snap-on TTC5 CDI 2000-400-02 CDI 2000-12-02 w/ 2000-810-01
30

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 30 of 31 Parameter/Equipment Range CMC2, 6 (±) Comments Gauge Pressure – Measuring Equipment (Pneumatic) (-90 to 0) kPa (0 to 100) kPa (100 to 200) kPa (200 to 700) kPa (700 to 2000) kPa 0.041 kPa 0.024 kPa 0.033 kPa 0.14 kPa 0.26 kPa Fluke PM500 w/ BG100K w/ BG200K w/ BG700K w/ BG2M; 6270A IV. Thermodynamics Parameter/Equipment Frequency CMC2, 6 (±) Comments Cold Junction Compensation (22 to 24) °C 0.031 °C Super-thermometer (1504A) /PRT reference thermometer, liquid baths & dry wells V. Time & Frequency Parameter/Equipment Frequency CMC 2, 6 (±) Comments Frequency – Measuring Equipment Measure 12 kHz to 3.2 GHz 10 MHz 10 Hz to 1 MHz 0.27 µHz/Hz 1.9 nHz/Hz 1.9 nHz/Hz + 0.6 R Wavetek 9500 option 100, Fluke 9500B FCA3103 w/ GPS FCA31xx w/o GPS, R = Resolution ___________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Ca pability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory ca n achieve within its scope of ac creditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.02) Revised 05/28/2026 Page 31 of 31 3 Field calibration service is ava ilable for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertai nty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibratin g instruments that measure or gene rate the values in the ranges indicated for the listed measurement parameter. 7 In the statement of CMC, percent is defined as percent of reading. 8 Digitized DC Voltage method utilized
32ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.