United States

SIMCO Electronics - Dallas

783 N. Grove Rd. Ste. 106, 75081, Richardson, TX, United States

Visit website
A2LA 1395.03A2LA 1395.26ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
39
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 39 scope lines.

A2LA certificate 1395.03 · 18 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 2 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Cylindrical Plug Gages & Master Discs Up to 1 in (1 to 12) in 10 µin (4.8 + 5L) µin Pratt & Whitney LabMaster™ Universal & gage blocks Cylindrical Ring Gages (0.040 to 1.0) in (>1.0 to 14) in 10 µin (8.8 + 3.3L) µin Pratt & Whitney LabMaster™ Universal & gage blocks Thread Plugs – UN (60° threads) UN Pitch Diameter: Up to 12 in, Pitch: (4 to 80) TPI Pitch Diameter: (1 to 300) mm, Pitch: (0.3 to 4) mm Major Diameter: Up to 1 in (1 to 12) in (70 + 5L) µin (1.7 + 0.13L) µm 10 µin (4.8 + 5L) µin Pratt & Whitney LabMaster™ Universal, gage blocks & thread wires Pratt & Whitney LabMaster™ Universal & gage blocks Wafer Film Thickness Standards (3.0 to 1500) nm 0.65 nm Woolam VASE system w/ NIST SRMs: NIST 2534 NIST 2531 NIST 2532 Precision Step Height Standards (10 to 100) nm (>100 to 2500) nm 2.5 % 0.6 % Veeco Dektak 3 comparator, Veeco 138 - 367, -369, -371 step height standards
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 3 of 17 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage3 – Generate Fixed Points Up to 220 mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (1 to 75) kV 1 V 1.018 V 10 V 8.1 µV/V + 0.4 µV 4.6 µV/V + 0.7 µV 3.5 µV/V + 2.5 µV 3.5 µV/V + 4 µV 4.4 µV/V + 40 µV 5.2 µV/V + 400 µV 0.16 % 2 μV/V 4 μV/V 1 μV/V Fluke Calibrator 5700A EP ROSS probe VD90-16.5Y-AK-K Fluke Zener standard 732A DC Voltage3 – Measure Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1050) V (1 to 90) kV 6.4 µV/V + 0.1 µV 4.1 µV/V + 0.4 µV 4.4 µV/V + 4.0 µV 5.9 µV/V + 40 µV 5.9 µV/V + 0.50 mV 0.16 % Fluke DMM 8508A ROSS probe VD90-16.5Y-AK-K DC Current3 – Generate Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (1 to 10) A (10 to 100) A 37 µA/A + 6 nA 32 µA/A + 7 nA 35 µA/A + 40 nA 41 µA/A + 0.7 µA 64 µA/A + 12 µA 0.034 % + 0.48 mA 0.015 % 0.052 % Fluke calibrator 5700A EP Fluke amplifier 5725A Guildline 9211A shunt, HP 6031A, Fluke DMM 8508A DC Current – Clamp Meters 3 (10 to 16.5) A (16.5 to 150) A (150 to 1000) A 0.40 % + 0.06 A 0.40 % + 0.06 A 0.40 % + 0.06 A Fluke 5500A/coil & 5520A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 4 of 17 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current3 – Measure Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (1 to 10) A (10 to 20) A (20 to 100) A (100 to 300) A 13 µA/A + 0.4 nA 13 µA/A + 4 nA 15 µA/A + 40 nA 50 µA/A + 0.8 µA 0.019 % + 16 µA 0.042 % + 0.40 mA 0.015 % 0.054 % 0.052 % 0.11 % Fluke DMM 8508A Guildline 9211A shunt, Fluke DMM 8508A Resistance3 – Generate Fixed Points (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.33 to 1.1) GΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω (100, 190) Ω 1 kΩ 1.9 kΩ (10, 19) kΩ 100 kΩ 190 kΩ 36 μΩ/Ω + 0.78 mΩ 27 μΩ/Ω + 1.2 mΩ 25 μΩ/Ω + 1.1 mΩ 25 μΩ/Ω + 1.6 mΩ 25 μΩ/Ω + 1.6 mΩ 26 μΩ/Ω + 16 mΩ 26 μΩ/Ω + 16 mΩ 26 μΩ/Ω + 0.16 Ω 26 μΩ/Ω + 0.16 Ω 28 μΩ/Ω + 1.6 Ω 28 μΩ/Ω + 1.6 Ω 50 μΩ/Ω + 24 Ω 0.011 % + 39 Ω 0.021 % + 2 kΩ 0.040 % + 2.4 kΩ 0.24 % + 78 kΩ 1.2 % + 0.39 MΩ 52 µΩ 84 µΩ/Ω 84 µΩ/Ω 24 µΩ/Ω 25 µΩ/Ω 11 µΩ/Ω 8.6 µΩ/Ω 8.0 µΩ/Ω 8.0 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω Fluke 5522A Fluke calibrator 5700A EP
to 20 A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 5 of 17 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Resistance3 – Generate (cont) Fixed Points 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 16 µΩ/Ω 17 µΩ/Ω 34 µΩ/Ω 42 µΩ/Ω 0.011 % Fluke calibrator 5700A EP Resistance3 – Measure Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 100) GΩ 20 µΩ/Ω + 4 µΩ 11 µΩ/Ω + 14 µΩ 8.6 µΩ/Ω + 50 µΩ 8.6 µΩ/Ω + 500 µΩ 8.6 µΩ/Ω + 5 mΩ 8.9 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1.0 Ω 24 µΩ/Ω + 0.10 kΩ 80 µΩ/Ω + 1 kΩ 0.022 % + 100 kΩ 0.74 % Fluke DMM 8508A Keithley 6517B Electrical Simulation of Thermocouples 3 – Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.41 °C 0.18 °C 0.17 °C 0.18 °C 0.21 °C 0.24 °C 0.18 °C 0.17 °C 0.18 °C 0.22 °C 0.28 °C 0.19 °C 0.18 °C 0.24 °C 0.33 °C 0.50 °C 0.22 °C 0.18 °C 0.17 °C Fluke calibrator 5522A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 6 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3– Generate Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.19 % + 4 µV 0.12 % + 4 µV 0.10 % + 4 µV 0.15 % + 4 µV 0.20 % + 5 µV 0.36 % + 10 µV 0.52 % + 20 µV 0.65 % + 20 µV 0.024 % + 4 µV 0.012 % + 4 µV 0.011 % + 4 µV 0.025 % + 4 µV 0.053 % + 5 µV 0.097 % + 10 µV 0.13 % + 20 µV 0.27 % + 20 µV 0.022 % + 12 µV 95 µV/V + 7 µV 79 µV/V + 7 µV 0.019 % + 7 µV 0.043 % + 17 µV 0.076 % + 20 µV 0.12 % + 25 µV 0.26 % + 45 µV 0.024 % + 40 µV 88 µV/V + 15 µV 47 µV/V + 8 µV 78 µV/V + 10 µV 0.011 % + 30 µV 0.036 % + 80 µV 0.091 % + 0.20 mV 0.15 % + 0.30 mV 0.022 % + 0.40 mV 89 µV/V + 0.15 mV 47 µV/V + 50 µV 77 µV/V + 0.10 mV 0.010 % + 0.20 mV 0.028 % + 0.60 mV 0.091 % + 2 mV 0.14 % + 3.2 mV Fluke calibrator 5700A EP Subject to a 2.2 x 10 7 V- Hz output
to 2.2 V
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 7 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (cont) (22 to 220) V (220 to 1100) V (220 to 750) V (750 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz (30 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz 0.022 % + 4.0 mV 88 µV/V + 1.5 mV 53 µV/V + 0.60 mV 87 µV/V + 1.0 mV 0.014 % + 2.5 mV 0.080 % + 16 mV 0.42 % + 40 mV 0.70 % + 80 mV 0.026 % + 16 mV 70 µV/V + 3.5 mV 0.037 % + 11 mV 0.14 % + 45 mV 87 µV/V + 4 mV 0.013 % + 6 mV 0.037 % + 11 mV Fluke calibrator 700A EP w/ Fluke amplifier 5725A (max. output = 250 V for [15 to 50] Hz) Fluke calibrator 700A EP Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage3 – Measure (1 to 65) kV (50 to 60) Hz 0.60 % Ross VD90-16.5Y-AK-K & Fluke 8508A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 8 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate Up to 220 µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.024 % + 16 nA 0.015 % + 10 nA 0.012 % + 8 nA 0.030 % + 12 nA 0.094 % + 65 nA 0.024 % + 40 nA 0.015 % + 35 nA 0.012 % + 35 nA 0.019 % + 110 nA 0.090 % + 0.65 µA 0.026 % + 0.40 µA 0.015 % + 0.35 µA 0.012 % + 0.35 µA 0.019 % + 0.55 µA 0.090 % + 5 µA 0.026 % + 4 µA 0.015 % + 3.5 µA 0.012 % + 2.5 µA 0.019 % + 3.5 µA 0.092 % + 10 µA 0.025 % + 35 µA 0.040 % + 80 µA 0.60 % + 0.16 mA 0.050 % + 0.17 mA 0.090 % + 0.38 mA 0.33 % + 0.75 mA Fluke calibrator 5700 A EP w/ Fluke 5725A
to 11 A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 9 of 17 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Current – Clamp Meters3– (0 to 500) A (500 to 1000) A (45 to 440) Hz (45 to 440) Hz 0.37 % + 0.1 A 0.39 % + 0.2 A Fluke 5522A w/5500 coil AC Current3 – Measure Up to 200 µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.037 % + 20 nA 0.031 % + 200 nA 0.032 % + 2 µA 0.030 % + 20 µA 0.062 % + 200 µA 0.075 % + 200 µA 0.082 % + 2 mA 0.25 % + 2 mA Fluke DMM 8508A Oscilloscope3 – DC Signal Rise/Fall Times ± 1 mV to ± 200 Vdc (into 50 Ω) ± 1 mV to ± 50 Vdc (into 1 MΩ) 40 μV to <1 mV pk-pk 1 mV to 200 Vpk-pk 50 kHz Reference Amplitude 0.1 Hz to 300 MHz (>300 to 550) MHz (>0.55 to 2.5) GHz (>2.5 to 3.0) GHz (350 to 550) ps 10 Hz to 2 MHz 0.061 % + 25 μV 0.061 % + 25 μV 0.83 % + 10 μV 0.16 % + 10 μV 1.2 % 2.2 % 2.5 % 2.8 % 2.8 % 33 ps Fluke 9500B scope calibrator w/ 9530 heads
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 10 of 17 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Oscilloscope3 – (cont) Rise/Fall Times Timing Marker Functions Pulse Width (125 to 175) ps 10 Hz to 2 MHz 9.0091 ns to <83 μs ≥83 μs to 55 s (1 to 100) ns 14 ps 0.2 μs/s 2.3 μs/s 4.1 % + 200 ps Fluke 9500B scope calibrator w/ 9530 heads Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF (1, 10) pF (100, 1000) pF (0.01, 0.1, 1) µF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 600 Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 1 kHz 0.61 % + 7.8 pF 0.44 % + 7.8 pF 0.42 % + 7.8 pF 0.24 % + 7.8 pF 0.23 % + 7.8 pF 0.23 % + 7.8 pF 0.23 % + 0.23 nF 0.23 % + 0.8 nF 0.23 % + 2.3 nF 0.23 % + 7.8 nF 0.33 % + 23 nF 0.37 % + 78 nF 0.37 % + 0.23 µF 0.37 % + 0.8 µF 0.37 % + 2.3 µF 0.37 % + 8 µF 0.59 % + 23 µF 0.86 % + 78 µF 0.13 % Fluke calibrator 5522A Agilent 16380A/16380C standard air capacitor set, BNC 4 terminal pair
to 55 s
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 11 of 17 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance3 – Generate (cont) Fixed Points: 1 pF 10 pF 100 pF 1000 pF 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 0.12 % 0.12 % 0.13 % 0.14 % 0.15 % 0.28 % 0.39 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.12 % 0.13 % 0.13 % 0.12 % 0.12 % 0.12 % 0.13 % 0.14 % 0.23 % 0.31 % Agilent 16380A/16380C standard air capacitor set, BNC 4 terminal pair Capacitance3 – Measure 1 pF to 1 µF 1 pF to 100 mF 1 kHz 20 Hz to 1 MHz 61 µF/F 0.064 % Andeen Hagerling 2500A capacitance bridge HP 4284A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 12 of 17 III. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 5 (±) Comments RF Power3 – Generate (+13 to -5) dBm (-6 to -45) dBm (-46 to -85) dBm (+20 to -100) dBm 200 Hz to 80 MHz 2.5 MHz to 26.5 GHz 0.09 dB 0.13 dB 0.20 dB 0.55 dB HP 3335A generator HP 8340B synthesizer w/ HP 8902 audio analyzer; HP 11722A, HP 11792A sensors, HP 11793A converter RF Power3 – Measure (-20 to + 30) dBm 100 kHz to 2.6 GHz 50 MHz to 26.5 GHz 0.056 dB + 1 digit 0.13 dB + 1 digit HP 8902A measuring receiver w/ HP 11792A power sensor Tuned RF Power – Measure (Relative) (+10 to 0) dB (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (0.15 to 1300) MHz 0.11 dB 0.11 dB 0.12 dB 0.14 dB 0.15 dB 0.16 dB 0.18 dB 0.21 dB 0.23 dB 0.25 dB 0.27 dB 0.29 dB 0.52 dB HP 8902A measuring receiver w/ HP 11722A power sensor
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 13 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments Tuned RF Power – Measure (Relative) (cont) (+10 to 0) dB (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (1.3 to 26.5) GHz 0.11 dB 0.11 dB 0.11 dB 0.13 dB 0.15 dB 0.16 dB 0.18 dB 0.21 dB 0.23 dB 0.25 dB 0.27 dB 0.29 dB 0.52 dB HP 8902A measuring receiver w/ HP 11793A converter, HP 11792A power sensor Amplitude Modulation3 – Measure Rate: 50 Hz to 10 kHz Depth: (5 to 99) % Rate: 20 Hz to 10 kHz Depth: To 99 % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 20 Hz to 100 kHz Depth: To 99 % Rate: 50 Hz to 50 kHz Depth: (5 to 99) % Rate: 20 Hz to 100 kHz Depth: To 99 % 150 kHz to 10 MHz (10 to 1300) MHz (1.3 to 26.5) GHz 2.1 % + 1 digit 3.0 % + 1 digit 1.1 % + 1 digit 3.0 % + 1 digit 1.6 % + 1 digit 3.0 % + 1 digit HP 8902A measuring receiver w/ HP 11793A converter, HP 11792A power sensor
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 14 of 17 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Frequency Modulation3 – Measure Rate: 20 Hz to 10 kHz Dev.: ≤40 kHz peak Rate: 50 Hz to 100 kHz Dev.: ≤400 kHz peak Rate: 20 Hz to 200 kHz Dev.: ≤400 kHz peak 250 kHz to 10 MHz (10 to 1300) MHz (10 to 1300) MHz 2.0 % + 1 digit 1.1 % + 1 digit 5.0 % + 1 digit HP 8902A measuring receiver Phase Modulation – Measure Rate: 200 Hz to 10 kHz Rate: 20 Hz to 200 kHz 150 kHz to 10 MHz 10 MHz to 26.5 GHz 4 % + 0.015 rad 5 % + 0.019 rad HP 8902A measuring receiver w/ HP 11792A power sensor Audio Distortion – Measure (-80 to 0) dB (-65 to 0) dB Harmonic Distortion – Measure & Measuring Equipment (-95 to 0) dB (20 Hz to 20 kHz (20 to 100) kHz >100 kHz to 13.2 GHz 1.7 dB 2.4 dB 2.7 dB HP 8903B audio analyzer HP 8563E spectrum analyzer In Line RF Power Meters – Measuring Equipment (1 to 80) W (0.1 to 500) MHz (0.5 to 1.0) GHz 1.7 % 1.9 % RF Attenuator, Agilent 8478B w/8482, Agilent N478 w/8482, AR amplifier
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 15 of 17 IV. Mechanical Parameter/Equipment Range CMC2, 4, 7 (±) Comments Scales & Balances3 (1 to 500) mg (0.5 to 5) g (5 to 20) g (20 to 500) g (0.5 to 5) kg (10 to 500) lb 0.024 mg + 0.6R 0.040 mg + 0.6R 0.078 mg + 0.6R 2.5 µg/g + 0.6R 5.4 µg/g + 0.6R 0.010 % + 0.6R Class 1 weights Class 2 weights Class F weights Pressure3 – Measuring Equipment Nitrogen Gas Hydraulic (0 to 90) psia (>90 to 300) psia (300 to 1000) psia (-14.5 to 300) psig (300 to 1000) psig (1000 to 2000) psig (2000 to 10 000) psig 0.0021 % + 0.009 psia + 0.58R 0.0054 % + 0.015 psia + 0.6R 0.01 % + 0.01 psia + 0.6R 0.0054 % + 0.015 psi + 0.6R 0.01 % + 0.01 psi + 0.6R 0.011 % + 2.1 psi + 0.6R 0.10 % + 0.45 psi + 0.6R Additel ADT780 pressure calibrator Crystal reference pressure gauge Torque – Measuring Equipment3 (1 to 10) ozf∙in (10 to 100) ozf∙in (5 to 50) lbf∙in 50 lbf∙in to 250 lbf∙ft 1.4 % 1.7 % 0.64 % + 0.58R 1.7 % Digital torque load cells V. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature3 – Measuring Equipment -80 °C ± 10 °C 0 °C (50 to 420) °C (420 to 660) °C 0.023 °C 0.023 °C 0.12 °C 0.17 °C Dry ice/alcohol slurry, PRT Wahl IPR4-1 ice point reference, PRT Fluke 9144 dry well, PRT calibrator 3125
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 16 of 17 Parameter/Equipment Range CMC2, 7 (±) Comments Temperature3 – Measure (Dry blocks, Ovens, Chambers, Furnaces, Freezers) (-196 to 400) °C (400 to 660) °C 0.018 °C 0.020 °C Hart Scientific 5626 PRT w/Fluke 8508A DMM VI. Time & Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments Frequency Reference 10 MHz Reference Signal 1.8 × 10-12 Hz/Hz Fluke 910 GPS receiver Frequency3 – Measuring Equipment 1 µHz to 26.5 GHz 1.8 x 10-12 Hz/Hz + 0.58R GPS receiver w/ synthesized generator Frequency3 – Measure DC to 225 MHz 225 MHz to 26.5 GHz 1.5 × 10-9 Hz/Hz + 5 µHz 1.8 × 10 -12 Hz/Hz + 1.3 Hz GPS receiver w/ 53132 counter 5343A counter Stopwatches & Timers3 (0 to 19.99) s/day 0.12 s/day Timometer __________________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.03) 12/01/2025 Page 17 of 17 a customer’s site being larger than the CMC. 4 In the statement of CMC, L is defined as the length of the unit under test in inches, D is the diameter of the unit under test in inches, R is the resolution of the device under test and % is percentage of reading, unless otherwise indicated. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
18ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA certificate 1395.26 · 21 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 2 of 20 Parameter/Equipment Range CMC2, 4 (±) Comments Thread Wires (Constant) – 60° Thread Wire Size – Wire Set 29° Thread Wire Size (4 to 80) TPI Constant (0.1 to 10) mm Constant (1 to 20) TPI 5.5 µin (17 µin) 0.14 µm (0.42 µm) 6.5 µin Pratt & Whitney LabMaster™, master thread wires English set Metric set Pratt & Whitney LabMaster™, gage blocks Threaded Plug Gages – UN (60° Threads) UN Pitch Diameter: Up to 12 in Pitch: (4 to 80) TPI Pitch Diameter: (1 to 300) mm Pitch: (0.3 to 4) mm Major Diameter: Up to 1 in (1 to 12) in (67 + 5L) µin (1.7 + 0.13L) µm (3.8 + 5L) µin (3.8 + 5L) µin Gage blocks w/ thread wire & Pratt & Whitney LabMaster™
4 to 80 TPI
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 3 of 20 II. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate Up to 220 µA >220 µA to 2.2 mA (>2.2 to 22) mA (>22 to 220) mA (>0.22 to 2.2) A (>2.2 to 11) A (>11 to 20) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 100 Hz 100 Hz to 1 kHz (1 to 5) kHz 0.024 % + 0.016 µA 0.016 % + 0.010 µA 0.012 % + 0.008 µA 0.03 % + 0.012 µA 0.094 % + 0.065 µA 0.024 % + 0.04 µA 0.015 % + 0.035 µA 0.012 % + 0.035 µA 0.020 % + 0.11 µA 0.091 % + 0.65 µA 0.026 % + 0.4 µA 0.016 % + 0.35 µA 0.012 % + 0.35 µA 0.019 % + 0.55 µA 0.091 % + 5 µA 0.027 % + 4 µA 0.016 % + 3.5 µA 0.013 % + 2.5 µA 0.020 % + 3.5 µA 0.092 % + 10 µA 0.025 % + 0.035 mA 0.025 % + 0.035 mA 0.041 % + 0.080 mA 0.61 % + 0.16 mA 0.042 % + 0.17 mA 0.086 % + 0.38 mA 0.33 % + 0.75 mA 0.13 % + 5 mA 0.16 % + 5 mA 3 % + 5 mA Fluke 5730A Fluke 5725A Fluke 5520A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 4 of 20 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Measure Up to 200 µA >200 µA to 2 mA (>2 to 20) mA (>20 to 200) mA >200 mA to 2 A (>2 to 10) A (>10 to 20) A (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz 17 µA/A + 30 pA 20 µA/A + 30 pA 21 µA/A + 0.3 nA 17 µA/A + 0.3 nA 20 µA/A + 0.3 nA 24 µA/A + 0.3 nA 43 µA/A + 30 nA 35 µA/A + 30 nA 54 µA/A + 30 nA 48 µA/A + 300 nA 34 µA/A + 300 nA 62 µA/A + 300 nA 58 µA/A + 3 µA 38 µA/A + 3 µA 100 µA/A + 3 µA 100 µA/A + 30 µA 65 µA/A + 30 µA 190 µA/A + 30 µA 150 µA/A + 300 µA 120 µA/A + 300 µA 620 µA/A + 400 µA Fluke A40 shunts, Fluke 5790B, metal film resistors AC Voltage – Generate Up to 2.2 mV (>2.2 to 22) mV (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (300 to 500) kHz (>0.5 to 1) MHz 0.039 % + 4 µV 0.081 % + 4 µV 0.096 % + 4 µV 0.032 % + 4 µV 0.057 % + 5 µV 0.13 % + 10 µV 0.21 % + 20 µV 0.36 % + 20 µV 0.025 % + 4 µV 0.013 % + 4 µV 0.013 % + 4 µV 0.019 % + 4 µV 0.05 % + 5 µV 0.09 % + 10 µV 0.12 % + 20 µV 0.29 % + 20 µV Fluke 5730A, opt 03
to 20 A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 5 of 20 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (>22 to 220) mV (>0.22 to 2.2) V (>2.2 to 22) V (>22 to 220) V (>220 to 1100) V (220 to 750) V (750 to 1100) V (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz (>0.5 to 1) MHz (15 to 50) Hz <50 Hz to 1 kHz (30 to 50) kHz (50 to 100) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz 0.023 % + 12 µV 0.009 % + 7 µV 0.008 % + 7 µV 0.019 % + 7 µV 0.043 % + 17 µV 0.077 % + 20 µV 0.12 % + 25 µV 0.26 % + 45 µV 0.023 % + 40 µV 0.008 % + 15 µV 0.0044 % + 8 µV 0.0072 % + 10 µV 0.011 % + 30 µV 0.035 % + 80 µV 0.091 % + 200 µV 0.16 % + 300 µV 0.022 % + 400 µV 0.0086 % + 150 µV 0.0045 % + 50 µV 0.007 % + 100 µV 0.010 % + 200 µV 0.030 % + 600 µV 0.091 % + 2000 µV 0.16 % + 3200 µV 0.023 % + 4 mV 0.0089 % + 1.5 mV 0.0054 % + 0.6 mV 0.0078 % + 1.0 mV 0.014 % + 2.5 mV 0.081 % + 16 mV 0.42 % + 40 mV 0.70 % + 80 mV 0.026 % + 16 mV 67 µV/V + 3.5 mV 0.037 % + 11 mV 0.13 % + 45 mV 87 µV/V + 4 mV 0.013 % + 6 mV 0.037 % + 11 mV Fluke 5730A Fluke 5730A opt 03 5730A opt 03, 5725A
6-Measuring Equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 6 of 20 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure, Measuring Equipment Up to 2.2 mV (>2.2 to 7) mV (>7 to 22) mV (>22 to 70) mV (>70 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 202 µV/V + 1.0 µV 203 µV/V + 1.0 µV 203 µV/V + 1.0 µV 203 µV/V + 1.6 µV 233 µV/V + 2.0 µV 310 µV/V + 3.2 µV 376 µV/V + 6.3 µV 1305 µV/V + 6.3 µV 81 µV/V + 1.0 µV 81 µV/V + 1.0 µV 81 µV/V + 1.0 µV 80 µV/V + 1.6 µV 90 µV/V + 2.0 µV 210 µV/V + 3.2 µV 263 µV/V + 6.3 µV 551 µV/V + 6.3 µV 71 µV/V + 1.0 µV 60 µV/V + 1.0 µV 40 µV/V + 1.0 µV 50 µV/V + 1.6 µV 85 µV/V + 2.0 µV 200 µV/V + 3.2 µV 250 µV/V + 6.3 µV 400 µV/V + 6.3 µV 100 µV/V + 1.2 µV 100 µV/V + 1.2 µV 67 µV/V + 1.2 µV 53 µV/V + 1.2 µV 72 µV/V + 1.6 µV 140 µV/V + 2.0 µV 270 µV/V + 3.2 µV 350 µV/V + 6.3 µV 410 µV/V + 6.3 µV 37 µV/V + 1.2 µV 37 µV/V + 1.2 µV 25 µV/V + 1.2 µV 19 µV/V + 1.2 µV 41 µV/V + 1.7 µV 76 µV/V + 2.0 µV 120 µV/V + 3.2 µV 130 µV/V + 6.3 µV 230 µV/V + 6.3 µV Fluke 5790B, Fluke 5730A opt 03
to 2.2 mV
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 7 of 20 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Measure (cont) (>220 to 700) mV >700 mV to 2.2 V (>2.2 to 7) V (>7 to 22) V (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 33 µV/V + 1.2 µV 33 µV/V + 1.2 µV 35 µV/V + 1.2 µV 12 µV/V + 1.2 µV 22 µV/V + 1.6 µV 23 µV/V + 2.0 µV 95 µV/V + 3.2 µV 76 µV/V + 6.3 µV 150 µV/V + 6.3 µV 30 µV/V 30 µV/V 23 µV/V 9 µV/V 14 µV/V 12 µV/V 90 µV/V 90 µV/V 240 µV/V 29 µV/V 29 µV/V 22 µV/V 9 µV/V 21 µV/V 11 µV/V 75 µV/V 75 µV/V 240 µV/V 28 µV/V 28 µV/V 30 µV/V 11 µV/V 11 µV/V 16 µV/V 85 µV/V 90 µV/V 240 µV/V Fluke 5790B
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 8 of 20 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Measure (cont) (>22 to 70) V (>70 to 220) V (>200 to 700) V (>700 to 1000) V (9.5 to 10) Hz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 27 µV/V 27 µV/V 22 µV/V 14 µV/V 31 µV/V 16 µV/V 71 µV/V 88 µV/V 110 µV/V 40 µV/V 23 µV/V 18 µV/V 16 µV/V 21 µV/V 29 µV/V 24 µV/V 22 µV/V 17 µV/V 18 µV/V 37 µV/V 55 µV/V 24 µV/V 22 µV/V 25 µV/V 42 µV/V 54 µV/V Fluke 5790B AC Flatness – Measure Up to 2.2 mV (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz 0.088 % 0.046 % 0.046 % 0.050 % 0.063 % + 0.75 µV 0.063 % + 0.78 µV 0.063 % + 0.78 µV 0.14 % + 0.78 µV 0.25 % + 0.78 µV 0.56 % + 1.6 µV 0.82 % + 1.6 µV 5790B wideband
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 9 of 20 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Flatness – Measure (cont) (2.2 to 7) mV (7 to 22) mV (22 to 70) mV (70 to 220) mV (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz 0.082 % 0.047 % 0.041 % 0.048 % 0.057 % + 0.78 µV 0.058 % + 0.78 µV 0.058 % + 0.78 µV 0.087 % + 0.78 µV 0.15 % + 0.78 µV 0.32 % + 0.78 µV 0.45 % + 0.78 µV 0.081 % 0.040 % 0.040 % 0.042 % 0.056 % 0.058 % 0.058 % 0.087 % 0.15 % 0.32 % 0.52 % 0.080 % 0.10 % 0.040 % 0.040 % 0.042 % 0.043 % 0.043 % 0.085 % 0.13 % 0.30 % 0.51 % 0.08 % 0.033 % 0.033 % 0.034 % 0.034 % 0.043 % 0.043 % 0.084 % 0.13 % 0.30 % 0.51 % 5790B wideband
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 10 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments AC Flatness – Measure (cont) (220 to 700) mV 700 mV to 2.2 V (2.2 to 7) V (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz (10 to 30) Hz (30 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 120) kHz (120 to 500) kHz 500 kHz to 1.2 MHz (1.2 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (30 to 50) MHz 0.079 % 0.025 % 0.025 % 0.025 % 0.028 % 0.043 % 0.043 % 0.083 % 0.13 % 0.30 % 0.51 % 0.079 % 0.025 % 0.025 % 0.025 % 0.027 % 0.043 % 0.043 % 0.083 % 0.13 % 0.30 % 0.50 % 0.079 % 0.025 % 0.025 % 0.025 % 0.027 % 0.043 % 0.043 % 0.083 % 0.13 % 0.30 % 0.50 % 5790B wideband
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 11 of 20 Parameter/Equipment Range CMC2, 3 (±) Comments Capacitance – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.9999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 10.9999) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.061 % + 0.0078 nF 0.44 % + 0.0078 nF 0.42 % + 0.0078 nF 0.24 % + 0.0078 nF 0.23 % + 0.078 nF 0.23 % + 0.078 nF 0.23 % + 0.23 nF 0.23 % + 0.8 nF 0.23 % + 2.3 nF 0.24 % + 7.8 nF 0.34 % + 24 nF 0.38 % + 78 nF 0.38 % + 23 nF 0.37 % + 0.8 µF 0.37 % + 2.3 µF 0.37 % + 7.8 µF 0.59 % + 24 µF 0.86 % + 78 µF Fluke 5520A Parameter/Range Frequency CMC2, 3, 4 (±) Comments Capacitance – Generate Fixed Points 10 pF 100 pF 1000 pF 10 nF 100 nF 1000 nF 1 pF 10 pF (100, 1000) pF (0.01, 0.1) µF 1 µF 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz (0.1, 0.4, 1) kHz 1 kHz 1 pF 0.016 % 0.01 % 6.5 µF/F 0.01 % 0.01 % 0.022 % 0.049 % 0.039 % 0.037 % 0.014 % 0.015 % 0.037 % 0.043 % 0.055 % 0.073 % 0.095 % 0.25 % 0.37 % GenRad capacitors Agilent 16380A/16380C standard air capacitor set, BNC 4 terminal pair Agilent 16380A/16380C standard air capacitor set, BNC 4 terminal pair
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 12 of 20 Parameter/Range Frequency CMC2, 3, 4 (±) Comments Capacitance – Generate (cont), Fixed Points 10 pF 100 pF 1000 pF 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 1 MHz 2 MHz 3 MHz 4 MHz 5 MHz 10 MHz 13 MHz 0.036 % 0.036 % 0.036 % 0.037 % 0.037 % 0.038 % 0.040 % 0.036 % 0.037 % 0.037 % 0.037 % 0.038 % 0.049 % 0.061 % 0.040 % 0.039 % 0.046 % 0.057 % 0.072 % 0.19 % 0.28 % Agilent 16380A/16380C standard air capacitor set, BNC 4 terminal pair Capacitance – Measure 1 pF to 1 µF 10 pF 100 pF 400 pF 1600 pF 6.4 nF 25 nF 100 nF 400 nF 1600 nF 6 µF 25 µF 100 µF 1000 µF 1 kHz 100 kHz 1 kHz 61 µF/F 0.0023 pF 0.023 pF 0.093 pF 0.37 pF 0.0015 nF 0.0058 nF 0.023 nF 0.093 nF 0.37 nF 0.0014 µF 0.0058 µF 0.024 µF 0.25 µF Andeen Hagerling 2500A capacitance bridge Genrad 1693
13--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 13 of 20 Parameter/Equipment Range CMC2, 3 (±) Comments Capacitance – Measure (cont) 200 µF to 110 mF 200 µF 300 µF 330 µF 700 µF 1.1 mF 2 mF 3 mF 3.3 mF 10.9 mF 20 mF 30 mF 33 mF 110 mF 210 µF/F 190 µF/F 180 µF/F 170 µF/F 160 µF/F 160 µF/F 160 µF/F 160 µF/F 160 µF/F 160 µF/F 160 µF/F 160 µF/F 180 µF/F Fluke 5730A, 3458A DC Current – Generate Up to 220 µA >220 µA to 2.2 mA (>2.2 to 22) mA (>22 to 220) mA >220 mA to 2.2 A (>2.2 to 11) A Up to 220 µA >220 µA to 2.2 mA (>2.2 to 22) mA (>22 to 220) mA >220 mA to 2.2 A (>2.2 to 11) A (11 to 20) A (20 to 100) A 40 µA/A + 6 nA 35 µA/A + 7 nA 35 µA/A + 40 nA 64 µA/A + 0.7 µA 60 µA/A + 12 µA 430 µA/A + 480 µA 2.9 µA/A + 0.21 nA 4.4 µA/A + 1.5 nA 8.0 µA/A + 38 nA 8.0 µA/A + 0.32 µA 3.0 µA/A + 0.31 µA 0.036 % + 480 µA 0.1 % + 0.75 mA 46 µA/A + 300 µA Fluke 5730A Fluke 5725A Fluke 5730A Fluke 8588A Standard resistors Fluke 5725A Fluke 5520A Valhalla 2555A, Guildline 9211A DC Current – Measure Up to 1 nA (>1 to 10) nA (>10 to 100) nA (>0.1 to 1) µA (>1 to 10) µA (>10 to 100) µA >100 µA to 1 mA (>1 to 10) mA (>10 to 100) mA >100 mA to 1 A (>1 to 10) A (>10 to 100) A 130 µA/A + 0.33 pA 33 µA/A + 0.036 pA 4.8 µA/A + 0.047 pA 4.6 µA/A + 0.3 pA 9.2 µA/A + 0.3 pA 4.8 µA/A + 30 pA 5.6 µA/A + 0.3 nA 5.2 µA/A + 30 nA 5.3 µA/A + 0.3 µA 6.4 µA/A + 3 µA 20 µA/A + 30 µA 46 µA/A + 0.3 mA HP 3458A precision resistors
to 110 mF
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 14 of 20 Parameter/Equipment Range CMC2, 3 (±) Comments DC Resistance – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (0.33 to 1.1) GΩ 34 µΩ/Ω + 0.78 mΩ 25 µΩ/Ω + 1.2 mΩ 23 µΩ/Ω + 1.1 mΩ 23 µΩ/Ω + 1.6 mΩ 24 µΩ/Ω + 1.6 mΩ 24 µΩ/Ω + 16 mΩ 23 µΩ/Ω + 16 mΩ 24 µΩ/Ω + 0.16 Ω 24 µΩ/Ω + 0.16 Ω 26 µΩ/Ω + 1.6 Ω 27 µΩ/Ω + 1.6 Ω 49 µΩ/Ω + 24 Ω 100 µΩ/Ω + 39 Ω 210 µΩ/Ω + 2 kΩ 400 µΩ/Ω + 2.4 kΩ 0.23 % + 78 kΩ 1.2 % + 0.39 MΩ Fluke 5520A/SC600 DC Resistance – Generate, Fixed Points 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 0.1 Ω 1 Ω 1.9 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 19 kΩ 100 kΩ 1 MΩ 10 MΩ 19 MΩ 83 µΩ/Ω 81 µΩ/Ω 23 µΩ/Ω 23 µΩ/Ω 10 µΩ/Ω 10 µΩ/Ω 8.1 µΩ/Ω 8.1 µΩ/Ω 8.1 µΩ/Ω 8.2 µΩ/Ω 9.6 µΩ/Ω 9.9 µΩ/Ω 16 µΩ/Ω 17 µΩ/Ω 35 µΩ/Ω 43 µΩ/Ω 120 µΩ/Ω 44 µΩ/Ω 2.5 µΩ/Ω 5.3 µΩ/Ω 2.0 µΩ/Ω 2.0 µΩ/Ω 1.5 µΩ/Ω 2.5 µΩ/Ω 1.5 µΩ/Ω 4.5 µΩ/Ω 4.1 µΩ/Ω 5.0 µΩ/Ω 11 µΩ/Ω Fluke 5730A Leeds & Northrup 4221, Fluke 742A-1, Fluke 742A-1.9, Fluke 742A-10, Fluke 742A-100, Fluke 742A-1k, Fluke 742A-10k, Fluke 742A-19k, Fluke 742A-100k, Fluke 742A-1M, Fluke 742A-10M, Fluke 742A-19M
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 15 of 20 Parameter/Equipment Range CMC2, 3, 4 (±) Comments DC Resistance – Measure 1 Ω 1.9 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 19 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ (>0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (200 to 2000) MΩ (2 to 20) GΩ 200 MΩ to 2 GΩ (2 to 20) GΩ (20 to 200) GΩ 200 GΩ to 2 TΩ 0.001 Ω 0.01 Ω 0.1 Ω 1.0 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 9.2 µΩ/Ω 9.5 µΩ/Ω 4.2 µΩ/Ω 2.9 µΩ/Ω 2.3 µΩ/Ω 3.6 µΩ/Ω 2.2 µΩ/Ω 6.4 µΩ/Ω 6.2 µΩ/Ω 19 µΩ/Ω 22 µΩ/Ω 19 µΩ/Ω + 4 µΩ 9.9 µΩ/Ω + 14 µΩ 8.4 µΩ/Ω + 50 µΩ 8.2 µΩ/Ω + 500 µΩ 8.1 µΩ/Ω + 5 mΩ 8.4 µΩ/Ω + 50 mΩ 10 µΩ/Ω + 1 Ω 23 µΩ/Ω + 100Ω 69 µΩ/Ω + 1 kΩ 180 µΩ/Ω + 100 kΩ 0.015 % + 10 MΩ 0.30 % 0.24 % 0.17 % 0.23 % 6.6 µΩ/Ω 1.2 µΩ/Ω 0.68 µΩ/Ω 0.67 µΩ/Ω 0.67 µΩ/Ω 0.95 µΩ/Ω 1.2 µΩ/Ω 1.1 µΩ/Ω 1.6 µΩ/Ω 2.2 µΩ/Ω 14 µΩ/Ω Fluke 8508A standard resistors Fluke 8508A Guildline 6520 teraohmmeter L&N 4214, 10 kΩ L&N 4210, 1 Ω MI 6000A bridge MI 6010C bridge & L&N working standard resistors in oil bath. Specific values are those which fall within ± 50 parts in 10 6 of the nominal value. Resistors are normally calibrated in an oil bath at 25 °C
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 16 of 20 Parameter/Equipment Range CMC2, 3, 4 (±) Comments DC Voltage – Generate Fixed Points (0 to 0.22) V (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 100 mV 1 V 10 V 100 V 1000 V 9.4 µV/V + 0.4 µV 3.8 µV/V + 0.7 µV 2.8 µV/V + 2.5 µV 2.8 µV/V + 4 µV 3.8 µV/V + 40 µV 4.8 µV/V + 400 µV 1.4 µV/V + 0.1 µV 1.1 µV/V + 0.1 µV 1.0 µV/V + 0.1 µV 1.1 µV/V + 0.1 µV 1.2 µV/V + 0.1 µV Fluke 5730A Fluke 732B Fluke 752A Fluke 8508A 5730A DC Voltage – Measure 100 mV 1 V 10 V 100 V 1 kV (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V 200 V to 1 kV 3.3 µV/V 1.2 µV/V 1.1 µV/V 1.1 µV/V 1.3 µV/V 6.0 µV/V + 0.1 µV 3.8 µV/V + 0.4 µV 3.7 µV/V + 4.0 µV 5.6 µV/V + 40 µV 5.7 µV/V + 500 µV Fluke 732B Fluke 752A Fluke 8508A Fluke 8508A Inductance – Generate, Fixed Points 50 µH 100 µH 1 mH 10 mH 20 mH 100 mH 1 H 5 H 10 H 0.09 % 0.04 % 0.02 % 0.02 % 0.20 % 0.02 % 0.02 % 0.04 % 0.06 % GenRad 1482J GenRad 1482B GenRad 1482E GenRad 1482H GenRad 1482A GenRad 1482L GenRad 1482P GenRad 1482R GenRad 1482T Inductance – Measure (50 to 100) µH 100 µH to 1 mH 1 mH to 1 H (1 to 5) H (5 to 10) H 0.067 % 0.050 % 0.033 % 0.036 % 0.038 % GenRad 1693 & standard inductors
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 17 of 20 Parameter/Equipment Range CMC2, 3 (±) Comments Phase Angle – Generate (0 to 360)° (10 to 65) Hz (>65 to 500) Hz >500 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz 0.14° 0.30° 0.59° 2.9° 5.8° Fluke 5520A/SC600 Phase Angle – Measure Voltage: Voltage (0 to 360)° 10 mV to 630 V Voltage: Current (0 to 360)° 10 mV to 630 V 300 mA to 20 A 5 Hz to 2 kHz (>2 to 5) kHz (>5 to 10) kHz (>10 to 50) kHz >50 kHz to 1 MHz 5 Hz to 2 kHz (>2 to 5) kHz (>5 to 10) kHz (>10 to 50) kHz >50 kHz to 1 MHz 0.016° 0.022° 0.024° 0.024° 0.15° 0.017° 0.023° 0.025° 0.025° 0.16° Clark Hess 6000A Clark Hess 6000A III. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 3 (±) Comments RF Power – Levelled Sine Wave Flatness (+20 to -30) dBm, 50 Ω (-20 to -70) dBm, 50 Ω 100 kHz to 4.2 GHz 10 MHz to 18 GHz 0.056 dB + 1 Digit 0.073 dB + 1 Digit Agilent HP 8482A, power meter Agilent HP 8481D, power meter
0 to 360 °
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 18 of 20 Parameter/Range Frequency CMC2, 3 (±) Comments Harmonic Distortion – Measure (-95 to 0) dB 50 kHz to 2.1 GHz 2.7 dB HP 8563E spectrum analyzer IV. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Torque Wrenches (1 to 10)ozf ∙in (10 to 100) ozf∙in (2.5 to 25) lbf∙in (25 to 250) lbf∙in (10 to 100) lbf∙ft (75 to 750) lbf∙ft 0.66 % + 0.58R 0.64 % + 0.58R 0.62 % + 0.58R 0.65 % + 0.58R 0.63 % + 0.58R 0.67 % + 0.58R A.W.S ITIO-10, ITIO- 100, ITI-25, ITI-250, ITF-100, ITF-750 Torque Transducers (1 to 40) ozf∙in (1 to 100) lbf∙in (>8 to 50) lbf∙ft (50 to 1000) lbf∙ft 0.07 % 0.07 % 0.04 % 0.05 % Weights, torque arms, torque wheels Shock Accelerometers – Measuring Equipment Shock Linearity (20 to 2000) g n (2000 to 10 000) gn 2.0 % 2.1 % Data acquisition card w/ 9155D-525 shock calibrator Accelerometers Voltage Sensitivity (0.1 to 1000) mV/gn Frequency Response Relative to 100 Hz 100 Hz (5 to 9) Hz (10 to 99) Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 to 15) kHz (15 to 20) kHz 0.63 % 1.2 % 0.82 % 0.78 % 0.92 % 1.6 % 1.6 % 2.1 % Data acquisition card w/ 9155D-525 shock calibrator
-95 to 0 dB
19--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 19 of 20 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Accelerometers – (cont) Charge Sensitivity, (0.02 to 5000) pC/gn Frequency Response Relative to 100 Hz 100 Hz (5 to 9) Hz (10 to 99) Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 to 15) kHz (15 to 20) kHz 0.63 % 1.2 % 0.82 % 0.78 % 0.92 % 1.6 % 1.6 % 2.1 % Data acquisition card w/ 9155D-525 shock calibrator V. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure (-200 to -38) °C (-38 to 0) °C (0 to 200) °C (200 to 420) °C 0.025 °C 0.013 °C 0.022 °C 0.034 °C Fluke 1502A W/5615- 12 VI. Time & Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments Frequency – Measure DC to 3 GHz 7.5 x 10-12 Hz/Hz + 0.58R GPS controlled frequency standard, 53131A Frequency – Generate DC to 3 GHz 10 MHz 7.5 x 10-12 Hz/Hz + 0.58R 7.5 x 10 -12 Hz/Hz GPS controlled frequency standard, Keysight N5171B Risetime – Measure (17.5 to 350) ps (0.25 to 2.5) V 1 kHz to 10 MHz 35 ps Keysight 86100A, 86105B _______________________________
0.02 to 5000 pC/gn
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 20 of 20 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 In the statement of CMC, R is the resolution of the unit under test; L is the numerical value of the nominal length of the device measured in inches. In the statement of CMC, the value is defined as the percentage of reading. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
21ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

783 N. Grove Rd. Ste. 106, Richardson, TX, 75081, US

32.94818, -96.72972

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.