Zakład Wodociągów i Kanalizacji (Szczecin)
ul. Szczawiowa 9-14, 70-010, Szczecin, Poland
- Accredited standards
- 36
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 36 standard numbers and the 36 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO29
ISO 5664Water quality - Determination of ammonium - Distillation and titration method
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 7980Water quality - Determination of calcium and magnesium - Atomic absorption spectrometric method
ISO 8288Water quality - Determination of cobalt, nickel, copper, zinc, cadmium and lead - Flame atomic absorption spectrometric methods
Show all 29
ISO 8467Water quality - Determination of permanganate index
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 9964-3Water quality - Determination of sodium and potassium - Part 3: Determination of sodium and potassium by flame emission spectrometry
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 11206Water quality - Determination of dissolved bromate - Method using ion chromatography (IC) and post column reaction (PCR)
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15586Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN7
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 903Water quality. Determination of anionic surfactants by measurement of the methylene blue index MBAS
EN 1483Water quality - Determination of mercury - Method using atomic absorption spectrometry
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-ISO 9297:1994; PN-EN 26777:1999; PN-ISO 5664:2002; PN-82/C-04576.08; PN-EN 25663:2001; PN-73/C-04576/14; PB/LC/04; PN-EN 1483:2007; PN-ISO 8288:2002; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 903:2002; PB/LC/08
PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN ISO 19458:2007; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12+ A1:2017-04; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7899-2:2004; PN-EN ISO 14189:2016-10; PN-EN ISO 16266:2009; PN-EN 26777:1999; PN-82/C-04576.08; PN-ISO 7150-1:2002; PN-ISO 6332:2001+Ap1:2016-06; PN-92/C-04605.02; PB/LC/01 wydanie 1 z dnia 09.04.2018 r. na podstawie testu Nanocolor nr 918 60; PN-92/C-04590/03; PB/LC/04 wydanie 1 z dnia 30.04.2018 r. na podstawie testu Nanocolor nr 985 062
PN-EN 1484:1999; PN-EN 27888:1999; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN ISO 6059:1999; PN-ISO 9964-3:1994; PN-ISO 9964-3:1994/Ak:1997; PN-EN ISO 7980:2002; PN-ISO 9297:1994; PN-EN ISO 10304-4:2022-08; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 11206:2013-07; PN-EN 1483:2007
PN-EN ISO 9963-1:2001+Ap1:2004; PN-EN ISO 8467:2001; PN-EN ISO 11885:2009; PB/LC/06; PN-ISO 8288:2002 metoda A; PN-EN ISO 10523:2012; PN-EN ISO 15586:2005
PN-EN 872:2007+Ap1:2007; PN-ISO 15705:2005; PN-EN ISO 9377-2:2003
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
6 lines
ISO/IEC 17025
ActiveAB 649
The scope document we hold says it is valid until 2029-11-01.
Accredited scope, certificate AB 649
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 649
Scope of accreditation No. AB 649
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 649
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 22 z/of 08.10.2025
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 649 z dnia 02.09.2019 r.
Cykl akredytacji od 08.10.2025 r. do 01.11.2029 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 649 of 02.09.2019
Accreditation cycle from 08.10.2025 to 01.11.2029
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 22, 08.10.2025 1/7
Nazwa i adres / Name and address
ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o.
ul. Maksymiliana Golisza 10
71-682 Szczecin
LABORATORIUM CENTRALNE
ul. Szczawiowa 9-14
70-010 Szczecin
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28/P; C/29/P;
C/30/P
- N/28/P; N/29/P;
N/30/P
- K/29/P
- Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków / Chemical
tests and sampling of water, drinking water, sewage
- Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków /
Tests of physical properties and sampling of water, drinking water, sewage
- Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological tests
and sampling of drinking water
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB-07 dostępnym na stronie internetowej www .pca.gov.pl /
The identification code according to the Annex to document DAB-07, available at PCA website www.pca .gov.pl
AB 649 | - |
| 2 | PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN ISO 19458:2007; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12+ A1:2017-04; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7899-2:2004; PN-EN ISO 14189:2016-10; PN-EN ISO 16266:2009; PN-EN 26777:1999; PN-82/C-04576.08; PN-ISO 7150-1:2002; PN-ISO 6332:2001+Ap1:2016-06; PN-92/C-04605.02; PB/LC/01 wydanie 1 z dnia 09.04.2018 r. na podstawie testu Nanocolor nr 918 60; PN-92/C-04590/03; PB/LC/04 wydanie 1 z dnia 30.04.2018 r. na podstawie testu Nanocolor nr 985 062 | Drinking water | See scope document |
| 3 | PN-EN 1484:1999; PN-EN 27888:1999; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN ISO 6059:1999; PN-ISO 9964-3:1994; PN-ISO 9964-3:1994/Ak:1997; PN-EN ISO 7980:2002; PN-ISO 9297:1994; PN-EN ISO 10304-4:2022-08; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO 11206:2013-07; PN-EN 1483:2007 | Drinking water | See scope document |
| 4 | PN-EN ISO 9963-1:2001+Ap1:2004; PN-EN ISO 8467:2001; PN-EN ISO 11885:2009; PB/LC/06; PN-ISO 8288:2002 metoda A; PN-EN ISO 10523:2012; PN-EN ISO 15586:2005 | Drinking water | See scope document |
| 5 | PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-ISO 9297:1994; PN-EN 26777:1999; PN-ISO 5664:2002; PN-82/C-04576.08; PN-EN 25663:2001; PN-73/C-04576/14; PB/LC/04; PN-EN 1483:2007; PN-ISO 8288:2002; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 903:2002; PB/LC/08 | Waste water | 1 to 35 °C |
| 6 | PN-EN 872:2007+Ap1:2007; PN-ISO 15705:2005; PN-EN ISO 9377-2:2003 | Water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Eurofins OBIKŚ PolskaKatowice · ~471 kmPCAShares 6 accredited methods and materialsEN 27888:1999EN 872:2007+Ap1:2007EN ISO 9963-1:2001+Ap1:2004
- LabAnalitykaBrzeg Dolny · ~281 kmPCAShares 5 accredited methods and materialsEN ISO 9963-1:2001+Ap1:2004ISO 5667-10:2021-11Drinking water
- ORLEN Laboratorium S.A.Płock · ~360 kmPCAShares 5 accredited methods and materialsEN 27888:1999EN ISO 9963-1:2001+Ap1:2004ISO 5667-10:2021-11
- "EKO-SERWIS" s.c. Dorota Markowska, Maciej MarkowskiŁódź · ~380 kmPCAShares 5 accredited methods and materialsEN 872:2007+Ap1:2007ISO 5667-5:2017-10Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~543 kmPCAShares 5 accredited methods and materialsEN 27888:1999ISO 5667-10:2021-11Drinking water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.