Registers refreshed 2026-11-20.See refresh dates
United States

Nel PreTech Corporation

8420 183rd Place, 60487, Tinley Park, IL, United States

Visit website
A2LA 2140.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2140.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2140.01) Revised 04/21/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 NEL PRETECH CORPORATION 8420 183rd Place Tinley Park, IL 60487 Jason Johnson Phone: 708 429 4887 MECHANICAL Valid To: March 31, 2026 Certificate Number: 2140.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following dimensional tests 1, 5: I. Dimensional Testing Parameter/Equipment Range CMC2, 4, 6 (±) Comments Length3 (1D) – Measure Up to 25 mm Up to 150 mm 2.7 µm 28 µm Micrometer Caliper Radius3 – Measure (1 to 15) mm (1/64 to 0.5) in 0.16 mm 0.01 in Radius gage Volume3 – (X, Y, Z) Measure (700 × 270 × 270) mm (1150 × 300 × 600) mm (100 × 70 × 60) mm (350 × 260 × 260) mm (700 × 1000 × 700) mm (900 x 1500 x 900) mm (700 x 1000 x 500) mm (400 x 400 x 300) mm (3.7 + 13L) µm (5.6 + 25L) µm 16 µm 37 µm (9.0 + 0.8L) µm (21 + 0.6L) µm (15 + 0.6L) µm (2.5 + 2.5L) µm Zeiss Metrotom 800 CT Zeiss Metrotom 1500 CT ATOS Q255, MV 100 ATOS Q255, MV350 B&S Global Image CMM B&S Xcel CMM B&S MicroXcel CMM Mycrona Altera S/L CMM
to 25 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2140.01) Revised 04/21/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Diameter3 – Measure (0.011 to 0.5) in 0.000 65 in Pin gages Area3 – (X, Y) Measure (300 x200) mm (300 × 300) mm (6.8 + 3.0L) µm (14 + 0.3L) µm Starrett AVR300 Optical CMM RAM optical CMM Angle3 – Measure (0 to 360)° (0.0002°/A) + 0.000 72° (0.000 32°/A) + 0.0014° (0.000 92°/A) + 0.0° (0.0021°/A) + 0.0° (0.000 39°/A) + 0.000 17° (0.0008°/A) + 0.000 17° (0.000 52°/A) + 0.000 046° (0.0012°/A) + 0.000 034° (0.000 84°/A) + 0.000 034° (0.000 14°/A) + 0.000 14° Zeiss Metrotom 800 CT Zeiss Metrotom 1500 CT ATOS Q255, MV100 ATOS Q255, MV350 Starrett AVR300 optical CMM RAM optical CMM B&S Global Image CMM B&S Xcel CMM B&S MicroXcel CMM Mycrona Altera S/L CMM Fixture Gages3 (700 × 1000 × 700) mm (900 × 1500 × 900) mm (700 × 1000 × 500) mm (9.0 + 0.8L) µm (21 + 0.6L) µm (15 + 0.6L) µm B&S Global CMM B&S Xcel CMM B&S MicroXcel CMM
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2140.01) Revised 04/21/2025 Page 3 of 3 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Surface Finish of Parts3 – Measure Ra (5 to 200) µin Rq (5 to 200) µin Rz (40 to 1200) µin (0.4 + 0.06S) µin (0.4 + 0.06S) µin (4.3 + 0.06S) µin Mahr MarSurf M400 __________________________________________________________________ 1 This laboratory offers commercial dimensional testing. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This test is not equivalent to that of a calibration. 4 In the statement of CMC, A is the numerical value of the shortest distance of the leg defining the angle in meters, S is the surface finish in the parameter in question in µin, and L is the measured length in meters. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being tested is defined by the parameter. This indicates the laboratory is capable of testing instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited NEL PRETECH CORPORATION Tinley Park, IL for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of any additional program requirements in the Mechanical field. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 6th day of March 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2140.01 Valid to March 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

8420 183rd Place, Tinley Park, IL, 60487, US

41.57337, -87.78449

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.