What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 2108.06 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.06) 03/05/2024 Page 1 of 5
SCOPE OF ACCREDITATION TO ISO 17025:2017
VIDEOJET X-RITE K.K.
West wing 6F, Telecom Center Bldg., 2-5-10, Aomi
Koto-ku, Tokyo 135-0064
JAPAN
Tel: +81-3-5579-6909 Fax: +81-3-5579-6547
Kevin Irwin Phone: 616 803 2118
CALIBRATION
Valid To: March 31, 2026 Certificate Number: 2108.06
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations
1, 7:
I. Optical Quantities
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
Model 962, 964, 939
(0/45 Optical
Geometry)
Model CI60, CI61,
CI62, CI64, CI64 UV,
CI4xxx
Model CI7xxx
3
Model 504, 508, 518,
528, 530 (0/45 Optical
Geometry)
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
(360 to 400) nm
(410 to 750) nm
(400 to 410) nm
(420 to 700) nm
1.7 % R
0.92 % R
0.95 % R
0.41 % R
0.83 % R
0.43 % R
1.7 % R
0.89 % R
White reflection
standards with:
SPP X-it 962
SPP CI6x
SPP CI7x
SPP X-it 500 | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.06) 03/05/2024 Page 2 of 5
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model Exact (0/45
Optical Geometry)
Model eXact 2 (ETV)
(0/45 Optical
Geometry)
Model MA9X
(Aspecular Optical
Geometry)
-15°
15°
25°
45°
75°
110°
(400 to 410) nm
(420 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400) nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
(400) nm
(410 to 700) nm
(400) nm
(410 to 700) nm
(400) nm
(410 to 700) nm
(400) nm
(410 to 700) nm
1.8 % R
1.1 % R
1.8 % R
1.1 % R
0.96 % R
0.99 % R
0.91 % R
0.78 % R
0.86 % R
0.75 % R
0.81 % R
0.70 % R
0.88 % R
0.80 % R
0.95 % R
0.90 % R
White reflection
standards with:
SPP exact
SPP ETV
SPP Finale 2
MA9x | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.06) 03/05/2024 Page 3 of 5
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model MA-x Series and
OEM Variants (TOP
Spectrophotometer)
(Aspecular Optical
Geometry)
15°
25°
45°
75°
110°
Model MA-x Series and
OEM variants (TOP 2
Spectro-photometer)
(Aspecular Optical
Geometry)
-15°
15°
25°
45°
75°
110°
(400 to 410) nm
(420 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
(400 to 700) nm
(400 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 410) nm
(420 to 700) nm
(400 to 700) nm
1.2 % R
1.1 % R
1.2 % R
1.1 % R
1.1 % R
0.96 % R
1.2 % R
1.0 % R
1.2 % R
1.6 % R
1.2 % R
1.1 % R
1.0 % R
1.1 % R
0.96 % R
1.1 % R
1.0 % R
1.2 % R
White reflection
standards with:
Topaz service
manual
Topaz 2 service
manual | 400 to 700 nm |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.06) 03/05/2024 Page 4 of 5
Parameter/Equipment5
Range
CMC2, 4 (±)
Comments6
Spectrophotometers –
(cont)
Model MA-Tx Series and
OEM Variants (KOH
Spectrophotometer)
(Aspecular Optical
Geometry)
-15°
15°
25°
45°
75°
110°
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
400 nm
(410 to 700) nm
(400 to 420) nm
(430 to 700) nm
400 nm
(410 to 700) nm
1.1 % R
1.0 % R
1.1 % R
0.85 % R
0.95 % R
0.80 % R
0.88 % R
0.73 % R
0.98 % R
0.78 % R
0.98 % R
0.92 % R
White reflection
standards with:
Kohinoor service
manual
Optical Radiation3
(Lightbooth)
2300 K (Horizon)
2856 K (Illuminate A)
20 K
22 K
X-Rite LightSpex
Pro radiometer
____________________________
1 This laboratory offers commercial calibration service and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2108.06) 03/05/2024 Page 5 of 5
4 In the statement of CMC, R is the reflectance.
5 The product families have the same optical geometries and calibration procedures. The features on the
display and outputs are the only differences.
6 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white
ceramic. Color calibration is mainly based on inter-instrument agreement.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VIDEOJET X-RITE K. K.
Tokyo, JAPAN
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 5th day of March 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2108.06
Valid to March 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
West wing 6F, Telecom Center Bldg., 2-5-10, Aomi, Koto-ku, Tokyo, 135-0064, Japan, Koto-ku, Tokyo, JP
35.67277, 139.81696
Open in MapsAccreditation data refreshed from the A2LA register on .