Japan

VideoJet X-Rite K. K.

West wing 6F, Telecom Center Bldg., 2-5-10, Aomi, Koto-ku, Tokyo, 135-0064, Japan, Koto-ku, Tokyo, Japan

Visit website
A2LA 2108.06ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 2108.06 · 6 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.06) 03/05/2024 Page 1 of 5 SCOPE OF ACCREDITATION TO ISO 17025:2017 VIDEOJET X-RITE K.K. West wing 6F, Telecom Center Bldg., 2-5-10, Aomi Koto-ku, Tokyo 135-0064 JAPAN Tel: +81-3-5579-6909 Fax: +81-3-5579-6547 Kevin Irwin Phone: 616 803 2118 CALIBRATION Valid To: March 31, 2026 Certificate Number: 2108.06 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Optical Quantities Parameter/Equipment5 Range CMC2, 4 (±) Comments6 Spectrophotometers – Model 962, 964, 939 (0/45 Optical Geometry) Model CI60, CI61, CI62, CI64, CI64 UV, CI4xxx Model CI7xxx 3 Model 504, 508, 518, 528, 530 (0/45 Optical Geometry) (400 to 410) nm (420 to 700) nm 400 nm (410 to 700) nm (360 to 400) nm (410 to 750) nm (400 to 410) nm (420 to 700) nm 1.7 % R 0.92 % R 0.95 % R 0.41 % R 0.83 % R 0.43 % R 1.7 % R 0.89 % R White reflection standards with: SPP X-it 962 SPP CI6x SPP CI7x SPP X-it 500
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.06) 03/05/2024 Page 2 of 5 Parameter/Equipment5 Range CMC2, 4 (±) Comments6 Spectrophotometers – (cont) Model Exact (0/45 Optical Geometry) Model eXact 2 (ETV) (0/45 Optical Geometry) Model MA9X (Aspecular Optical Geometry) -15° 15° 25° 45° 75° 110° (400 to 410) nm (420 to 700) nm (400 to 410) nm (420 to 700) nm (400) nm (410 to 700) nm (400 to 420) nm (430 to 700) nm (400) nm (410 to 700) nm (400) nm (410 to 700) nm (400) nm (410 to 700) nm (400) nm (410 to 700) nm 1.8 % R 1.1 % R 1.8 % R 1.1 % R 0.96 % R 0.99 % R 0.91 % R 0.78 % R 0.86 % R 0.75 % R 0.81 % R 0.70 % R 0.88 % R 0.80 % R 0.95 % R 0.90 % R White reflection standards with: SPP exact SPP ETV SPP Finale 2 MA9x
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.06) 03/05/2024 Page 3 of 5 Parameter/Equipment5 Range CMC2, 4 (±) Comments6 Spectrophotometers – (cont) Model MA-x Series and OEM Variants (TOP Spectrophotometer) (Aspecular Optical Geometry) 15° 25° 45° 75° 110° Model MA-x Series and OEM variants (TOP 2 Spectro-photometer) (Aspecular Optical Geometry) -15° 15° 25° 45° 75° 110° (400 to 410) nm (420 to 700) nm 400 nm (410 to 700) nm 400 nm (410 to 700) nm (400 to 410) nm (420 to 700) nm (400 to 700) nm (400 to 700) nm (400 to 700) nm 400 nm (410 to 700) nm 400 nm (410 to 700) nm (400 to 410) nm (420 to 700) nm (400 to 700) nm 1.2 % R 1.1 % R 1.2 % R 1.1 % R 1.1 % R 0.96 % R 1.2 % R 1.0 % R 1.2 % R 1.6 % R 1.2 % R 1.1 % R 1.0 % R 1.1 % R 0.96 % R 1.1 % R 1.0 % R 1.2 % R White reflection standards with: Topaz service manual Topaz 2 service manual
400 to 700 nm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.06) 03/05/2024 Page 4 of 5 Parameter/Equipment5 Range CMC2, 4 (±) Comments6 Spectrophotometers – (cont) Model MA-Tx Series and OEM Variants (KOH Spectrophotometer) (Aspecular Optical Geometry) -15° 15° 25° 45° 75° 110° 400 nm (410 to 700) nm (400 to 420) nm (430 to 700) nm 400 nm (410 to 700) nm 400 nm (410 to 700) nm (400 to 420) nm (430 to 700) nm 400 nm (410 to 700) nm 1.1 % R 1.0 % R 1.1 % R 0.85 % R 0.95 % R 0.80 % R 0.88 % R 0.73 % R 0.98 % R 0.78 % R 0.98 % R 0.92 % R White reflection standards with: Kohinoor service manual Optical Radiation3 (Lightbooth) 2300 K (Horizon) 2856 K (Illuminate A) 20 K 22 K X-Rite LightSpex Pro radiometer ____________________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2108.06) 03/05/2024 Page 5 of 5 4 In the statement of CMC, R is the reflectance. 5 The product families have the same optical geometries and calibration procedures. The features on the display and outputs are the only differences. 6 White reflection standards apply to the calibration of approximately 80 % reflectance on a neutral white ceramic. Color calibration is mainly based on inter-instrument agreement. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
6

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited VIDEOJET X-RITE K. K. Tokyo, JAPAN for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of March 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2108.06 Valid to March 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

West wing 6F, Telecom Center Bldg., 2-5-10, Aomi, Koto-ku, Tokyo, 135-0064, Japan, Koto-ku, Tokyo, JP

35.67277, 139.81696

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.