Registers refreshed 2026-11-20.See refresh dates
Poland

Otwockie Przedsiębiorstwo Wodociągów i Kanalizacji

Józefa Ignacego Kraszewskiego 1, 05-402, Otwock, Poland

PCA AB 1034ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
23
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 23 standard numbers and the 23 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO18
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9280Water quality - Determination of sulfate - Gravimetric method using barium chloride
Show all 18
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10523Water quality - Determination of pH
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 19458Water quality - Sampling for microbiological analysis
EN5
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

4 lines
PCA

ISO/IEC 17025

Active

AB 1034

The scope document we hold says it is valid until 2029-04-20.

View on PCA

Accredited scope, certificate AB 1034

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1034 Scope of accreditation No. AB 1034 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1034 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa ul. Szczotkarska 42 Wydanie/Issue 21 z/of 03.02.2026 p.o. KIEROWNIKA DZIAŁU AKREDYTACJI BADAŃ CHEMICZNYCH MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1034 z dnia 21.03.2023 r. Cykl akredytacji od 20.03.2025 r. do 20.04.2029 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 1034 of 21.03.2023 Accreditation cycle from 20.03.2025 to 20.04.2029 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr/ Issue No. 21, 03.02.2026 1/5 Nazwa i adres / Name and address OTWOCKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. LABORATORIUM ul. Józefa Ignacego Kraszewskiego 1 05-402 Otwock Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: ­ C/29/P, C/30/P ­ N/29/P, N/30/P ­ K/29/P ­ Q/29 ­ Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi , ścieków / Chemical tests and sampling of drinking water, sewage ­ Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi , ścieków / Tests of physical properties and sampling of drinking water, sewage ­ Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological tests and sampling of drinking water ­ Badania sensoryczne wody do spożycia przez ludzi / Sensory tests of drinking water Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 1034
-
2PN-ISO 5667-5:2017-10; PN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 14189:2016-10; PN-ISO 6332:2001+Ap1:2016-06; PB-01.00 wydanie 8 z dnia 12.10.2023; PN-EN ISO 7887:2012 metoda C +Ap1:2015-06; PN-EN ISO 7027-1:2016-09; PN-ISO 6059:1999; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-EN 1622:2006Drinking waterSee scope document
3PN-ISO 5667-10:2021-11; PN-EN 872:2007+Ap1:2007; PN-ISO 15705:2005; PB-10.00 wydanie 4 z dnia 10.09.2019; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-ISO 7150-1:2002; PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010; PB-11.00 wydanie 5 z dnia 10.09.2019; PB-04.00 wydanie 5 z dnia 10.09.2019; PN-EN ISO 5815-1:2019; PN-EN 1899-2:2002Waste waterSee scope document
4PN-EN 26777:1999; PB-06.00; PN-ISO 9297:1994; PN-ISO 9280:2002Drinking waterSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Józefa Ignacego Kraszewskiego 1, Otwock, 05-402, PL

52.09654, 21.23671

Open in Maps

Accreditation data refreshed from the PCA register on .