Scope lines
17
A2LA certificate
1
Sites in our directory
6
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 3630.03 · 17 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 1 of 16 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PYLON ELECTRONICS INC. 6355 Danville Road, Unit 10 Mississauga, Ontario CANADA L5T 5L4 Louis Abate Phone: 905 362 1395 x 2201 CALIBRATION Valid To: September 30, 2026 Certificate Number: 3630.03 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Hand Tools3, 9 – Calipers (OD/ID/Depth) Depth Gages Height Gages Dial Indicators Thickness Gage Micrometers OD Flatness Micrometers ID Micrometers Depth Flatness Up to 40 in (1000 mm) Up to 24 in (600 mm) Up to 40 in (1000 mm) Up to 4 in (100 mm) (> 4 to 12) in (300 mm) Up to 8 in (200 mm) Up to 24 in (600 mm) Up to 0.001 in Up to 24 in (600 mm) Up to 24 in (600 mm) Up to 0.001 in 320 µin (8.2 µm) 300 µin (7.7 µm) (62 + 2.2L) µin (5.7 + 20L) µin (10 + 44L) µin (6.5 + 1.5L) µin (12 + 4.1L) µin 10 µin (60 + 2.1L) µin (34 + 3.6L) µin 10 µin Gauge blocks Gauge blocks Gauge blocks ULM Gauge blocks Gauge blocks Gauge blocks Optical flat ULM, gauge blocks Gauge blocks Optical flat
to 40 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 2 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Gage Blocks – Steel, Ceramic, Carbide, Chrome Carbide: Length Parallelism Steel Only: Length Parallelism Length Parallelism (0.010 to 4) in (5 to 8) in (10 to 20) in (2.3 + 1L) µin 3 µin (3 + 1L) µin 3 µin (10 + 2.7L) µin 3 µin Gage block comparison Angle Blocks Up to 60° 3 arcsec Sine bar/gauge blocks Plug Gages – Parallel Plain (0.007 to 24) in (11 + 1.5L) µin ULM with gage block Tapered Plain Plug Gages – Diameter Taper Length/Step Up to 6 in Up to 6 in Up to 6 in 60 µin 90 µin 150 µin Taper measuring machine Gage block/MuCheck Pin Gages/Set Up to 1 in 25 µin SuperMICTM, setting disc Plain Snap Gages Up to 12 in (110 + 1.5L) µin By comparison Plain Ring Gages – Parallel (0.04 to 6) in (6 to 12) in (10 + 1L) µin (11 + 1.5L) µin ULM with master ring
3ANSI B89.1.17-See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 4 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Thread Ring Gages – Parallel Adjustable Type Functional Pitch Diameter Minor Diameter (0.06 to 12) in Up to 12 in (320 + 15L) µin 70 µin By comparison, fit to master plug Bore micrometer/gage block & pins Thread Ring Gages – Parallel Non-Adjustable Type Simple Pitch Diameter Minor Diameter (0.5 to 6) in Up to 6 in 120 µin 70 µin By comparison Bore micrometer/gage block & pins Thread Ring Gauge – Taper Non-Adjustable Simple Pitch Diameter Standoff Taper Step/Length Up to 4 in Up to 6 in Up to 4 in Up to 6 in 150 µin 250 µin 150 µin 150 µin ULM/plain ring Master plug PD measurements Gage blocks/MuCheck Thread Caliper Gauges – Adjustable Pitch Diameter Up to 6 in (400 + 6L) µin Fit to master/setting plug Step Masters Up to 1 in (1 to 24) in 30 µin (30 + 2L) µin Electronic amp, probe, gage blocks Length Standards – Setting Rods Up to 48 in (13 + 2L) µin By comparison
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 5 of 16 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Height Masters Up to 24 in (0.6R + 3L) µin Gage blocks/MuCheck Micrometers – High Resolution Linearity Force Up to 1 in Up to 48 lbf 15 µin 0.03 lbf Gage block Force gauge Bore Gages 2-Point 3-Point (0.5 to 24) in Up to 6 in (0.6R + 50) µin (0.6R + 82 + 10L) µin By comparison Plain setting ring High Resolution Comparators Up to 2 in 2.2 µin Master blocks Sine Bars & Plates Up to 10 in 40 µin/5 in By comparison Precision Levels Up to 18 in (0.6R + 15) µin Level test rig Steel Ruler Up to 40 in 0.000 22 in Optical comparator Protractors Up to 180° 0.01° Angle blocks sine plate/gage blocks One Dimensional Measurement – Diameter Length Up to 10 in Up to 10 in 110 µin 110 µin Bench micrometer Bench micrometer Two Dimensional Measurement – Angle Up to 360° 0° 3’ Optical comparator
to 24 in
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 6 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Universal Length Measuring Machine Up to 26 in (4 in travel) (2.6 + 1.1L) µin Master blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1020) V (0 to 10) kV (10 to 140) kV 11 µV/V + 0.35 µV 9.6 µV/V + 0.34 µV 9.6 µV/V + 0.57 µV 12 µV/V + 35 µV [12 + (14.V/1000)2] µV/V + 120 µV 0.034 % + 0.034 V 0.091 % + 0.8 V Agilent 3458A V = voltage Vitrek 4700 w/ HVL-150 probe DC Voltage3 – Generate (0 to 329.9999) mV (0.33 to 3.299 999) V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1000.000) V 16 µV/V + 0.78 µV 8.6 µV/V + 1.6 µV 9.4 µV/V + 16 µV 14 µV/V + 120 µV 14 µV/V + 1200 µV Fluke 552X series calibrator DC Current3 – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 24 µA/A + 0.93 nA 24 µA/A + 5.8 nA 24 µA/A + 58 nA 41 µA/A + 0.58 µA 0.013 % + 12 µA Agilent 3458A DC Current3 – Generate (0 to 329.999) µA (0.330 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A 0.012 % + 0.016 µA 78 µA/A + 0.039 µA 78 µA/A + 0.20 µA 78 µA/A + 2.0 µA 0.016 % + 32 µA 0.03 % + 32 µA 0.039 % + 390 µA 0.078 % + 580 µA Fluke 552X series calibrator
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 7 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current3 – Generate (cont) Clamp-On Meters (20 to 149.999) A (150 to 549.999) A (550 to 1025) A 0.58 % + 0.17 A 0.58 % + 0.58 A 0.59 % + 0.58 A Fluke 552X series w/ Fluke 5500A/coil Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 18 µΩ/Ω + 58 µΩ 15 µΩ/Ω + 0.58 mΩ 13 µΩ/Ω + 0.57 mΩ 13 µΩ/Ω + 5.7 mΩ 13 µΩ/Ω + 56 mΩ 18 µΩ/Ω + 2.3 Ω 58 µΩ/Ω + 120 Ω 0.058 % + 1200 Ω 0.58 % + 12 kΩ Agilent 3458A Resistance3 – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 32 µΩ/Ω + 0.78 mΩ 24 µΩ/Ω + 1.2 mΩ 22 µΩ/Ω + 1.1 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 0.16 Ω 22 µΩ/Ω + 0.16 Ω 25 µΩ/Ω + 1.6 Ω 25 µΩ/Ω + 1.6 Ω 47 µΩ/Ω + 24 Ω 0.011 % + 36 Ω 0.02 % + 2.0 kΩ 0.039 % + 2.4 kΩ 0.24 % + 78 kΩ 1.2 % + 390 kΩ Fluke 552X series calibrator
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 8 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (1 to 10) mV (10 to 100) mV (0.1 to 1.0) V (1.0 to 10.0) V (10.0 to 100.0) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.035 % + 3.5 µV 0.024 % + 1.3 µV 0.035 % + 1.3 µV 0.12 % + 1.3 µV 0.58 % + 1.3 µV 4.7 % + 2.4 µV 0.0081 % + 4.7 µV 0.0081 % + 2.4 µV 0.017 % + 2.4 µV 0.035 % + 2.4 µV 0.093 % + 2.4 µV 0.35 % + 12 µV 1.2 % + 12 µV 1.8 % + 12 µV 0.0081 % + 47 µV 0.0081 % + 24 µV 0.017 % + 24 µV 0.035 % + 24 µV 0.093 % + 24 µV 0.35 % + 120 µV 1.2 % + 120 µV 1.8 % + 120 µV 0.0081 % + 0.47 mV 0.0081 % + 0.24 mV 0.017 % + 0.24 mV 0.035 % + 0.24 mV 0.093 % + 0.24 mV 0.35 % + 1.2 mV 1.2 % + 1.2 mV 1.8 % + 1.2 mV 0.024 % + 4.7 mV 0.024 % + 2.4 mV 0.024 % + 2.4 mV 0.041 % + 2.4 mV 0.14 % + 2.4 mV 0.47 % + 12 mV 1.8 % + 12 mV Agilent 3458A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 9 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (cont) (100.0 to 700) V (0.1 to 10) kV (10 to 100) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 60 Hz 0.047 % + 47 mV 0.047 % + 24 mV 0.07 % + 24 mV 0.14 % + 24 mV 0.35 % + 24 mV 0.14 % + 0.11 V 0.57 % + 1.1 V Agilent 3458A Vitrek 4700 w/ HLV-150 probe AC Voltage3 – Generate (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.063 % + 4.7 µV 0.012 % + 4.7 µV 0.016 % + 4.7 µV 0.078 % + 4.7 µV 0.28 % + 9.4 µV 0.63 % + 39 µV 0.024 % + 6.3 µV 0.012 % + 6.3 µV 0.013 % + 6.3 µV 0.028 % + 6.3 µV 0.063 % + 25 µV 0.16 % + 55 µV 0.024 % + 39 µV 0.012 % + 47 µV 0.015 % + 47 µV 0.024 % + 39 µV 0.055 % + 97 µV 0.19 % + 470 µV 0.024 % + 510 µV 0.012 % + 470 µV 0.019 % + 470 µV 0.028 % + 470 µV 0.07 % + 1300 µV Fluke 552X series calibrator
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 10 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (cont) (33 to 329.999) V (330 to 1020) V 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.015 % + 1600 µV 0.016 % + 4700 µV 0.02 % + 4700 µV 0.024 % + 4700 µV 0.16 % + 39 000 µV 0.024 % + 7800 µV 0.02 % + 7800 µV 0.024 % + 7800 µV Fluke 552X series calibrator AC Current3 – Measure (5 to 100) µA (0.05 to 1) mA (0.5 to 10) mA (5 to 100) mA (0.05 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz 0.47 % + 0.035 µA 0.18 % + 0.035 µA 0.07 % + 0.035 µA 0.07 % + 0.035 µA 0.47 % + 0.24 µA 0.18 % + 0.24 µA 0.07 % + 0.24 µA 0.035 % + 0.24 µA 0.47 % + 2.4 µA 0.18 % + 2.4 µA 0.07 % + 2.4 µA 0.035 % + 2.4 µA 0.47 % + 24 µA 0.18 % + 24 µA 0.07 % + 24 µA 0.035 % + 24 µA 0.47 % + 240 µA 0.19 % + 240 µA 0.093 % + 240 µA 0.12 % + 240 µA Agilent 3458A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 11 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.16 % + 0.078 µA 0.12 % + 0.078 µA 0.097 % + 0.078 µA 0.24 % + 0.12 µA 0.63 % + 0.16 µA 1.3 % + 0.32 µA 0.16 % + 0.12 µA 0.097 % + 0.12 µA 0.078 % + 0.12 µA 0.16 % + 0.16 µA 0.39 % + 0.24 µA 0.78 % + 0.47 µA 0.14 % + 1.6 µA 0.07 % + 1.6 µA 0.032 % + 1.6 µA 0.063 % + 1.6 µA 0.16 % + 2.4 µA 0.32 % + 3.2 µA 0.14 % + 16 µA 0.07 % + 16 µA 0.032 % + 16 µA 0.078 % + 39 µA 0.16 % + 78 µA 0.32 % + 160 µA 0.14 % + 78 µA 0.039 % + 78 µA 0.47 % + 780 µA 2.0 % + 3900 µA 0.14 % + 78 µA 0.047 % + 78 µA 0.47 % + 780 µA 2.0 % + 3900 µA 0.047 % + 1600 µA 0.078 % + 1600 µA 2.4 % + 1600 µA 0.094 % + 3900 µA 0.12 % + 3900 µA 2.4 % + 3900 µA Fluke 552X series calibrator
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 12 of 16 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current3 – Generate (cont) Clamp-On Meters: (Toroidal Type) (20 to 54.999) A (55 to 149.999) A (150 to 1025) A (20 to 54.999) A (55 to 149.999) A (150 to 400) A (Non-Toroidal Type) (20 to 149.999) A (150 to 549.999) A (550 to 1025) A (20 to 149.999) A (150 to 400) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.31 % + 0.054 A 0.34 % + 0.042 A 0.34 % + 0.13 A 0.93 % + 0.054 A 0.94 % + 0.046 A 1.2 % + 0.22 A 0.65 % + 0.30 A 0.66 % + 1.1 A 0.65 % + 1.1 A 1.2 % + 0.30 A 1.4 % + 1.1 A Fluke 552X series w/ Fluke 5500A/coil Capacitance3 – Generate (0.22 to 0.399 99) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.39 % + 0.0078 nF 0.39 % + 0.0078 nF 0.39 % + 0.0078 nF 0.20 % + 0.0078 nF 0.20 % + 0.078 nF 0.20 % + 0.078 nF 0.20 % + 0.24 nF 0.20 % + 0.78 nF 0.20 % + 2.4 nF 0.20 % + 7.8 nF 0.32 % + 24 nF 0.35 % + 78 nF 0.35 % + 240 nF 0.35 % + 0.78 µF 0.35 % + 2.4 µF 0.35 % + 7.8 µF 0.59 % + 24 µF 0.86 % + 78 µF Fluke 552X series calibrator
13--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 13 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicating Devices 3 – Generate Type B Type E Type J Type K Type N Type R Type S (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C 0.35 °C 0.27 °C 0.24 °C 0.26 °C 0.39 °C 0.13 °C 0.11 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.11 °C 0.14 °C 0.18 °C 0.26 °C 0.14 °C 0.13 °C 0.21 °C 0.32 °C 0.32 °C 0.18 °C 0.15 °C 0.14 °C 0.21 °C 0.45 °C 0.28 °C 0.26 °C 0.32 °C 0.37 °C 0.28 °C 0.29 °C 0.36 °C Fluke 552X series calibrator
to 1820 °C
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 14 of 16 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Electrical Simulation of Thermocouples & Thermocouple Indicating Devices 3 – Generate (cont) Type T (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.49 °C 0.19 °C 0.13 °C 0.11 °C Fluke 552X series calibrator Electrical Simulation of RTD Indicators & Indicating Systems 3 – Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.039 °C 0.039 °C 0.055 °C 0.07 °C 0.078 °C 0.094 °C 0.18 °C Fluke 552X series calibrator Oscilloscopes3 – Amplitude – DC Signal 50 Ω Load 1 MΩ Load Amplitude – Square Wave 50 Ω Load 1 MΩ Load Bandwidth Flatness Time Marker Resistance – Measure 1 mV to 6.6 V 1 mV to 130 V 1 mV to 6.6 V pp 10 Hz to 100 kHz 1 mV to 130 Vpp 10 Hz to 100 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 ms to 5 s 2 ns to 20 ms (40 to 60) Ω (0.5 to 1.5) MΩ 0.20 % + 32 µV 0.039 % + 32 µV 0.20 % + 32 µV 0.078 % + 32 µV 1.2 % + 78 µV 1.6 % + 78 µV 3.2 % + 78 µV 3.9 % + 78 µV (20 + (t*1000)) µs/s 1.9 µs/s 0.079 % 0.078 % 552XA/SC1100 t = time in seconds
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 15 of 16 III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Pneumatic & Hydraulic Gage Pressure9 (-14.2 to 0) psig (0 to 6) psig (6 to 15 000) psig 0.036 psi 0.006 psi 0.10 % Digital pressure standard Torque Wrenches 10 oz·in to 1000 lbf·ft 0.6 % Norbar 43236 torque standard, CDI – DTT transducers IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments IR Thermometers (35 to 500) °C 0.25 °C + 0.21 % Fluke 4181 ε = 0.95, λ = (8 to 14) μm V. Time & Frequency Parameter/Equipment Range CMC2, 6, 8 (±) Comments Frequency3 – Measure (1 to 40) Hz 40 Hz to 10 MHz 0.058 % 0.12 % Agilent 3458A Frequency3 – Measuring Equipment 0.01 Hz to 2 MHz Up to 500 MHz 2 µHz/Hz + 3.9 µHz 2 µHz/Hz Fluke 5522A Fluke 5522A/SC1100  1 This laboratory offers commercial calibration service and field calibration service where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3630.03) 08/05/2024 Page 16 of 16 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches for Imperial units, or in millimeters for metric units, and R is the resolution unit under test. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 In the statement of CMC, percentages are to be read as percent of reading, unless otherwise noted. 7 This scope meets A2LA’s P112 Flexible Scope Policy 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 The contributions attributed to the repeatability of the “best existing device” are not included in the CMC claim.
17ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.