Registers refreshed 2026-11-20.See refresh dates
United States

FireflySci North America

Part of FireflySci Canada, 5720 South Bay Road, 13039, Cicero, NY, United States

Visit website
A2LA 7344.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 7344.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No.7344.01) Revised 05/14/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FIREFLYSCI NORTH AMERICA 5720 South Bay Road Cicero, NY 13039 Part of FireflySCI Canada Mario Noel Email: ISO@FireflySciCanada.com Website: http://www.FireflySciCanada.com CALIBRATION Valid To: July 31, 2026 Certificate Number: 7344.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s - R025 Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Optical – Radiation, Photometric, Etc. Calibrations Parameter/Equipment Range CMC 2 (±) Comments Wavelength 3 (240 to 875) nm 0.25 nm Scanning spectrophotometer Absorbance 3 0.04 to 3.0 at fixed nominal absorbance values (± 10 % of nominal value), measured within 250 nm and 635 nm wavelength range 0.0009 to 0.0046, see Table 1 and Table 2 Scanning spectrophotometer
240 to 875 nm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No.7344.01) Revised 05/14/2025 Page 2 of 3 Table 1: Absorbance CMC Uncertainties4 Nominal Absorbance Wavelength (nm) 250.0 280.0 340.0 360.0 400.0 440.0 0.04 0.0009 0.0009 0.0009 0.0009 0.0009 0.0009 0.2 - - - - 0.001 0.001 0.5 0.0018 0.0018 0.0018 0.0018 0.0018 0.0009 1 0.0019 0.0019 0.0019 0.0019 0.0035 0.0033 1.5 - - - - - 0.0034 2 - - - - - 0.0046 2.5 - - - - - 0.0043 3 - - - - - 0.0077 Table 2: Absorbance CMC Uncertainties4 Nominal Absorbance Wavelength (nm) 465.0 500.0 546.1 590.0 635.0 0.04 0.0009 0.0009 0.0009 0.0009 0.0009 0.2 0.001 0.0009 0.0009 0.0009 0.0009 0.5 0.001 0.0009 0.001 0.001 0.001 1 0.0032 0.0032 0.0032 0.0032 0.0032 1.5 0.0033 - 0.0034 0.0034 0.0034 2 0.0045 - 0.0045 0.0046 0.0034 2.5 0.0033 - 0.0033 0.0046 0.0032 3 0.0045 - 0.0045 0.005 0.0033 _______________________________________ 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC’s found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC’s.
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No.7344.01) Revised 05/14/2025 Page 3 of 3 4 A “-“ in the table means that the calibration is outside of the scope capabilities. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited FIREFLYSCI NORTH AMERICA Circeco, NY for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of July 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7344.01 Valid to July 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Part of FireflySci Canada, 5720 South Bay Road, Cicero, NY, 13039, US

43.17562, -76.11937

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.