A2LA certificate 1741.23 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 1 of 13
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
CROSS TECHNOLOGIES, INC
2154 N Center Street, Suite 406
North Charleston, SC 29406
Connie Foster Phone: 800 327 7727
CALIBRATION
Valid To: October 31, 2027 Certificate Number: 1741.23
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s R205 – Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 8:
I. Chemical
Parameter/Equipment
Range
CMC2 (±)
Comments
pH Meters3 – Fixed
Points
4 pH
7 pH
10 pH
0.027 pH
0.027 pH
0.027 pH
Standard pH solutions
Conductivity Meters3
100 μS/cm
1413 μS/cm
10 000 μS/cm
2.2 µS
5.9 µS
38 µS
Standard conductivity
solutions
II. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Pin Gage3 – Class Z &
Class ZZ
Up to 1 in
84 µin
Micrometer | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 2 of 13
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Calipers3
Up to 40 in
(4.3 +10L) µin + 0.6R
Gage blocks
Micrometers3
Up to 40 in
(19 + 8.6L) µin + 0.6R
Gage blocks
Height Gages3
Up to 20 in
(20 to 48) in
(6.1 + 9.1L) µin + 0.6R
(12 + 8.8L) µin + 0.6R
Gage blocks
Steel Rules3
Up to 72 in
(3.1 + 9.6L) µin + 0.6R
Gage blocks
Tape Measures3
Up to 25 ft
(2.8 + 9.9L) µin + 0.6R
Gage blocks
Angle Indicators &
Protractors3
30°, 45°, 60°, 75°,
90°
0.031°
Angle block set
Feeler/Thickness Gages3
Up to 1 in
84 µin
Micrometer
Linear Indicators3 – Dial,
test, & LVDT
Up to 4 in
(6.2 + 8.1L) µin + 0.6R
Gage blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage – Measure3
Up to 50 mV
(50 to 500) mV
500 mV to 5 V
(5 to 50) V
(50 to 500) V
(500 to 1000) V
(1 to 6) kV
0.06 % + 0.02 mV
0.03 % + 0.02 mV
0.03 % + 0.2 mV
0.03 % + 2 mV
0.036 % + 0.02 V
0.036 % + 0.2V
1.3 %
Fluke 287
Fluke 80K-6 & DMM | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 3 of 13
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage – Generate3
(0 to 120) mV
(0 to 1.2) V
(0 to 12) V
(12 to 120) V
(120 to 1020) V
43 μV/V + 1.6 μV
28 μV/V + 2 μV
28 μV/V + 20 μV
39 μV/V + 200 μV
39 μV/V + 2 mV
Fluke 5540A
DC Current – Measure3
Up to 5 mA
(5 to 50) mA
(50 to 400) mA
400 mA to 5 A
(5 to 10) A
(1 to 50) A
0.1 % + 0.2 µA
0.07 % + 0.01 mA
0.19 % + 0.02 mA
0.37 % + 1 mA
0.37 % + 2 mA
0.31 %
Fluke 287
Empro shunt w/ DMM
DC Current– Generate3
Clamp-On Meters3 –
(0 to 120) μA
(0 to 1.2) mA
(0 to 12) mA
(0 to 120) mA
(0 to 1.2) A
(1.2 to 3.1) A
(0 to 12) A
(12 to 30.2) A
(20.5 to 1000) A
0.013 % + 0.0072 μA
0.01 % + 0.018 μA
0.011 % + 0.096 μA
0.014 % + 2.5 μA
0.055 % + 12 μA
0.034 % + 180 μA
0.043 % + 300 μA
0.22 % + 600 μA
0.65 % + 0.5 A
Fluke 5540A
Fluke 5522A w/5500 coil
Resistance – Measure3
Up to 50 Ω
(50 to 500) Ω
500 Ω to 5 kΩ
(5 to 50) kΩ
(50 to 500) kΩ
500 kΩ to 5 MΩ
(5 to 30) MΩ
(30 to 50) MΩ
(50 to 100) MΩ
0.018 % + 0.02 Ω
0.06 % + 0.1 Ω
0.06 % + 0.2 Ω
0.06 % + 2 Ω
0.06 % + 20 Ω
0.19 % + 200 Ω
1.8 % + 4 kΩ
1.8 % + 40 kΩ
3.6 % + 200 kΩ
Fluke 287 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 4 of 13
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
Resistance – Generate3
(0 to 12) Ω
(12 to 120) Ω
120 Ω to 1.2 kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
120 MΩ to 1.2 GΩ
58 μΩ/Ω + 0.0015 Ω
61 μΩ/Ω + 0.0015 Ω
58 μΩ/Ω + 0.004 Ω
58 μΩ/Ω + 0.04 Ω
58 μΩ/Ω + 0.4 Ω
58 μΩ/Ω + 4 Ω
58 μΩ/Ω + 520 Ω
0.046 % + 50 kΩ
0.58 % + 5 MΩ
Fluke 5540A
Capacitance – Generate3
(0.12 to 1.2) nF
(1.2 to 12) nF
(12 to 120) nF
(0.12 to 1.2) µF
(1.2 to 12) µF
(12 to 120) µF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
(100 to 10 000) Hz
(150 to 5000) Hz
(200 to 1300) Hz
(2 to 310) Hz
(0.5 to 110) Hz
(0.5 to 40) Hz
(0.1 to 11) Hz
(0.03 to 4) Hz
(0.01 to 1.3) Hz
0.5 % + 05 pF
0.33 % + 10 pF
0.23 % + 50 pF
0.23 % + 500 pF
0.23 % + 5 nF
0.32 % + 50 nF
0.42 % + 500 nF
0.41 % + 5 µF
0.91 % + 50 µF
Fluke 5540A
AC Voltage – Generate3
(0 to 12) mV
(12 to 120) mV
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.55 % + 15 μV
0.27 % + 15 μV
0.14 % + 7 μV
0.11 % + 7 μV
1.4 % + 18 μV
7.2 % + 36 μV
7.2 % + 36 μV
0.55 % + 15 μV
0.27 % + 15 μV
0.091 % + 7 μV
0.19 % + 20 μV
0.26 % + 26 μV
3.6 % + 400 μV
3.6 % + 400 μV
Fluke 5540A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 5 of 13
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Generate3 (cont)
(0.12 to 1.2) V
(1.2 to 12) V
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
0.55 % + 150 μV
0.27 % + 150 μV
0.091 % + 85 μV
0.091 % + 40 μV
0.19 % + 200 μV
0.26 % + 260 μV
3.6 % + 4 mV
3.6 % + 4 mV
0.55 % + 1.5 mV
0.27 % + 1.5 mV
0.091 % + 500 μV
0.091 % + 500 μV
0.19 % + 2 mV
0.26 % + 2.6 mV
3.6 % + 40 mV
3.6 % + 40 mV
0.55 % + 15 mV
0.27 % + 15 mV
0.091 % + 4 mV
0.091 % + 4 mV
0.21 % + 20 mV
0.27 % + 26 mV
0.55 % + 150 mV
0.27 % + 150 mV
0.091 % + 100 mV
0.21 % + 390 mV
0.28 % + 520 mV
0.55 % + 150 mV
0.27 % + 150 mV
0.091 % + 100 mV
Fluke 5540A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 6 of 13
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure3
(5 to 50) V
(50 to 500) V
(500 to 1000) V
(1 to 6) kV
(45 to 65) Hz
65 Hz to 10 kHz
(10 to 20) kHz
(45 to 65) Hz
65 Hz to 10 kHz
(45 to 65) Hz
65 Hz to 10 kHz
60 Hz
0.37 % + 0.025 V
0.49 % + 0.025 V
0.85 % + 0.04 V
0.37 % + 0.25 V
0.49 % + 0.25 V
0.37 % + 2.5 V
0.49 % + 2.5 V
1.6 %
Fluke 287
Fluke 80K-6 & DMM
AC Current – Generate3
(0.12 to 120) μA
120 μA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
120 mA to 1.2 A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.19 % + 0.02 µA
0.19 % + 0.1 µA
0.19 % + 0.02 µA
0.46 % + 0.15 µA
0.46 % + 1 µA
0.19 % + 0.2 µA
0.19 % + 0.2 µA
0.19 % + 0.2 µA
0.36 % + 0.3 µA
0.46 % + 5 µA
0.19 % + 2 µA
0.19 % + 2 µA
0.19 % + 2 µA
0.19 % + 3 μA
0.46 % + 10 µA
0.19 % + 20 µA
0.19 % + 20 µA
0.19 % + 20 µA
0.19 % + 30 µA
0.46 % + 100 µA
0.19 % + 100 µA
0.19 % + 100 µA
0.19 % + 100 µA
0.22 % + 300 µA
0.46 % + 300 µA
Fluke 5540A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 7 of 13
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Generate3
(cont)
(1.2 to 3.1) A
(3.1 to 12) A
(11 to 20.5) A
Clamp-On Meters
3 –
(10 to 150) A:
Toroidal
Non-Toroidal
(150 to 1025) A:
Toroidal
Non-Toroidal
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.19 % + 1 mA
0.19 % + 1 mA
0.19 % + 1 mA
0.91 % + 1.5 mA
0.19 % + 2 mA
0.19 % + 2 mA
0.19 % + 2 mA
0.91 % + 4 mA
0.46 % + 50 mA
0.46 % + 50 mA
0.46 % + 50 mA
0.47 % + 0.025 A
1 % + 0.027 A
0.75 % + 0.25 A
1.3 % + 0.25 A
0.64 % + 0.09 A
1.1 % + 0.1 A
0.86 % + 0.9 A
1.4 % + 0.9 A
Fluke 5540A
Fluke 5540A w/ 5500
coil
AC Current – Measure3
(0 to 500) µA
500 µA to 5 mA
(5 to 50) mA
(50 to 400) mA
400 mA to 5 A
(5 to 10) A
45 Hz to 1 kHz
0.74 % + 0.2 µA
0.74 % + 0.5 µA
0.73 % + 0.02 mA
0.73 % + 0.05 mA
0.97 % + 2 mA
0.97 % + 5 mA
Fluke 287 | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 8 of 13
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples &
Measure 3 –
Type B
Type E
Type J
Type K
Type N
Type S
Type T
(600 to 800) °C
(800 to 1820) °C
(-250 to -150) °C
(-150 to 350) °C
(350 to 1000) °C
(-210 to -100) °C
(-100 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 400) °C
0.40 °C
0.33 °C
0.36 °C
0.18 °C
0.20 °C
0.23 °C
0.17 °C
0.20 °C
0.26 °C
0.20 °C
0.32 °C
0.31 °C
0.19 °C
0.20 °C
0.39 °C
0.31 °C
0.38 °C
0.55 °C
0.22 °C
0.14 °C
Fluke 5540A
Electrical Calibration of
RTD’s3 –
Pt 385-100:
Measure
Simulation
(-200 to 100) °C
(100 to 800) °C
(-200 to 100) °C
(100 to 800) °C
0.12 °C
0.26 °C
0.06 °C
0.17 °C
Fluke 754 series | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 9 of 13 | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 10 of 13
IV. Fluid Quantities
Parameter/Equipment
Range
CMC2, 6, 5 (±)
Comments
Viscosity Meters3
Up to 100 cP
(100 to 1000) cP
0.52 %
0.55 %
Standard viscosity
solutions w/ bath
V. Mechanical
Parameter/Equipment
Range
CMC2, 5, 6, 7 (±)
Comments
Scales & Balances3
(1 to 500) mg
Up to 5 g
Up to 10 g
Up to 30 g
Up to 50 g
Up to 100 g
Up to 200 g
Up to 300 g
Up to 500 g
Up to 1000 g
(> 1 to 11) kg
(5 to 10) g
(10 to 500) g
501 g to 20 kg
(> 20 to 80) kg
Up to 1000 lb
0.013 mg + 0.6R
0.043 mg + 0.6R
0.062 mg + 0.6R
0.096 mg + 0.6R
0.17 mg + 0.6R
0.31 mg + 0.6R
0.63 mg + 0.6R
0.92 mg + 0.6R
1.5 mg + 0.6R
3.1 mg + 0.6R
3.1 mg per 1000 g + 0.6R
0.04 % + 0.6R
0.025 % + 0.6R
0.017 % + 0.6R
0.017 % per 20 kg + 0.6R
0.017 % + 0.6R
ASTM Class 1
weights
(applied load)
Class F weights
(applied load)
Class F weights
(applied load)
Force3 – Measuring
Equipment
Up to 1 000 lbf
Up to 10 000 lbf
0.017 % + 0.6R
0.014 % of applied load
Class F weights
Load cell w/
indicator
Torque – Measure3 –
Wrenches – Click, Dial,
Adjustable, Screwdrivers
5 to 1000 lbf∙in
20 to 600 lbf∙ft
0.74 %
0.64 %
CDI Suretest 5000-
ST | to 1000 cP |
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 11 of 13
Parameter/Equipment
Range
CMC 2, 5, 6, 7 (±)
Comments
Pressure – Measure &
Measuring Equipment3
Pneumatic
Hydraulic
Up to 300 psig
(300 to 3000) psig
(5 to 10 000) psig
0.18 psi
1.9 psi
6.4 psi
ADT-680 series
Atmospheric Pressure –
Measure & Measuring
Equipment (Vacuum)3
(0.01 to 28.5) in Hg
0.37 in Hg
ADT-680 series
Speed Measure3 –
Optic/Non-Contact:
RPM
Totalizer/Rate Meters
Contact:
RPM
Totalizer/Rate Meters
(6 to 100 000) rpm
(2 to 3300) fpm
(6 to 20 000) rpm
(2 to 3300) fpm
0.017 %
0.017 %
0.21 %
0.21 %
Monarch PLT200
Totalize Meters3 –
Distance Measure –
Mechanical
Counter/Totalizers3
Up to 200 ft
Up to 999 999 counts
0.63 %
(0.02 % + 0.6R)
Monarch PLT200
w/ 10 cm wheel | to 3000 psig |
| 12 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 12 of 13
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Relative Humidity –
Measure3
(10 to 80) % RH
1.3 % RH
Rotronic HP32A w/
HC2A-S probe
Relative Humidity
Measuring Equipment3
(10 to 80) % RH
1.3 % RH
Humidity source w/
Rotronic HP32A w/
HC2A-S probe
Temperature – Measure3
(-40 to 660) °C
0.051 °C
Isotech TTI -10 w/PRT
Temperature – Measuring
Equipment3
(-25 to 140) °C
(50 to 650) °C
0.07 °C
0.15 °C
Isotech Hyperion w/ PRT
Isotech Jupiter w/PRT
Infrared Thermometry –
Measuring Equipment3
35 °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.80 °C
0.94 °C
1.2 °C
1.7 °C
2.3 °C
Fluke 4181
λ = (8 to 14) µm, where ε
= 0.95”
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Timers & Stopwatches3
(1 to 3600) s
0.3 s
Monarch PLT 200
Frequency – Measuring
Equipment3
0.01 Hz to 2 MHz
5.4 ppm + 5 μHz
Fluke 5540A
______________________________________________________________
1 This laboratory offers commercial calibration and field calibration services, where noted. | 10 to 80 % RH |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.23) 11/25/2025 Page 13 of 13
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the labor atory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. re solution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as ei ther a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is the numerical value of the resolution of the device.
6 In the statement of CMC, percentages are percent of reading, unless otherwise indicated.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
CROSS TECHNOLOGIES, INC
North Charleston, SC
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this November 25th, 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1741.23
Valid to October 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.