CROSS TECHNOLOGIES, INC - NORTH CHARLESTON

2154 N Center Street, Suite 406, 29406, North Charleston, SC, United States

Visit website
A2LA 1741.23ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 14 scope lines.

A2LA certificate 1741.23 · 14 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 1 of 13 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS TECHNOLOGIES, INC 2154 N Center Street, Suite 406 North Charleston, SC 29406 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: October 31, 2027 Certificate Number: 1741.23 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s R205 – Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 8: I. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meters3 – Fixed Points 4 pH 7 pH 10 pH 0.027 pH 0.027 pH 0.027 pH Standard pH solutions Conductivity Meters3 100 μS/cm 1413 μS/cm 10 000 μS/cm 2.2 µS 5.9 µS 38 µS Standard conductivity solutions II. Dimensional Parameter/Equipment Range CMC2 (±) Comments Pin Gage3 – Class Z & Class ZZ Up to 1 in 84 µin Micrometer
to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 2 of 13 Parameter/Equipment Range CMC2, 5 (±) Comments Calipers3 Up to 40 in (4.3 +10L) µin + 0.6R Gage blocks Micrometers3 Up to 40 in (19 + 8.6L) µin + 0.6R Gage blocks Height Gages3 Up to 20 in (20 to 48) in (6.1 + 9.1L) µin + 0.6R (12 + 8.8L) µin + 0.6R Gage blocks Steel Rules3 Up to 72 in (3.1 + 9.6L) µin + 0.6R Gage blocks Tape Measures3 Up to 25 ft (2.8 + 9.9L) µin + 0.6R Gage blocks Angle Indicators & Protractors3 30°, 45°, 60°, 75°, 90° 0.031° Angle block set Feeler/Thickness Gages3 Up to 1 in 84 µin Micrometer Linear Indicators3 – Dial, test, & LVDT Up to 4 in (6.2 + 8.1L) µin + 0.6R Gage blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Measure3 Up to 50 mV (50 to 500) mV 500 mV to 5 V (5 to 50) V (50 to 500) V (500 to 1000) V (1 to 6) kV 0.06 % + 0.02 mV 0.03 % + 0.02 mV 0.03 % + 0.2 mV 0.03 % + 2 mV 0.036 % + 0.02 V 0.036 % + 0.2V 1.3 % Fluke 287 Fluke 80K-6 & DMM
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 3 of 13 Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Generate3 (0 to 120) mV (0 to 1.2) V (0 to 12) V (12 to 120) V (120 to 1020) V 43 μV/V + 1.6 μV 28 μV/V + 2 μV 28 μV/V + 20 μV 39 μV/V + 200 μV 39 μV/V + 2 mV Fluke 5540A DC Current – Measure3 Up to 5 mA (5 to 50) mA (50 to 400) mA 400 mA to 5 A (5 to 10) A (1 to 50) A 0.1 % + 0.2 µA 0.07 % + 0.01 mA 0.19 % + 0.02 mA 0.37 % + 1 mA 0.37 % + 2 mA 0.31 % Fluke 287 Empro shunt w/ DMM DC Current– Generate3 Clamp-On Meters3 – (0 to 120) μA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.2) A (1.2 to 3.1) A (0 to 12) A (12 to 30.2) A (20.5 to 1000) A 0.013 % + 0.0072 μA 0.01 % + 0.018 μA 0.011 % + 0.096 μA 0.014 % + 2.5 μA 0.055 % + 12 μA 0.034 % + 180 μA 0.043 % + 300 μA 0.22 % + 600 μA 0.65 % + 0.5 A Fluke 5540A Fluke 5522A w/5500 coil Resistance – Measure3 Up to 50 Ω (50 to 500) Ω 500 Ω to 5 kΩ (5 to 50) kΩ (50 to 500) kΩ 500 kΩ to 5 MΩ (5 to 30) MΩ (30 to 50) MΩ (50 to 100) MΩ 0.018 % + 0.02 Ω 0.06 % + 0.1 Ω 0.06 % + 0.2 Ω 0.06 % + 2 Ω 0.06 % + 20 Ω 0.19 % + 200 Ω 1.8 % + 4 kΩ 1.8 % + 40 kΩ 3.6 % + 200 kΩ Fluke 287
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 4 of 13 Parameter/Range Frequency CMC2, 4, 6 (±) Comments Resistance – Generate3 (0 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ 120 MΩ to 1.2 GΩ 58 μΩ/Ω + 0.0015 Ω 61 μΩ/Ω + 0.0015 Ω 58 μΩ/Ω + 0.004 Ω 58 μΩ/Ω + 0.04 Ω 58 μΩ/Ω + 0.4 Ω 58 μΩ/Ω + 4 Ω 58 μΩ/Ω + 520 Ω 0.046 % + 50 kΩ 0.58 % + 5 MΩ Fluke 5540A Capacitance – Generate3 (0.12 to 1.2) nF (1.2 to 12) nF (12 to 120) nF (0.12 to 1.2) µF (1.2 to 12) µF (12 to 120) µF (0.12 to 1.2) mF (1.2 to 12) mF (12 to 120) mF (100 to 10 000) Hz (150 to 5000) Hz (200 to 1300) Hz (2 to 310) Hz (0.5 to 110) Hz (0.5 to 40) Hz (0.1 to 11) Hz (0.03 to 4) Hz (0.01 to 1.3) Hz 0.5 % + 05 pF 0.33 % + 10 pF 0.23 % + 50 pF 0.23 % + 500 pF 0.23 % + 5 nF 0.32 % + 50 nF 0.42 % + 500 nF 0.41 % + 5 µF 0.91 % + 50 µF Fluke 5540A AC Voltage – Generate3 (0 to 12) mV (12 to 120) mV (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.55 % + 15 μV 0.27 % + 15 μV 0.14 % + 7 μV 0.11 % + 7 μV 1.4 % + 18 μV 7.2 % + 36 μV 7.2 % + 36 μV 0.55 % + 15 μV 0.27 % + 15 μV 0.091 % + 7 μV 0.19 % + 20 μV 0.26 % + 26 μV 3.6 % + 400 μV 3.6 % + 400 μV Fluke 5540A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 5 of 13 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Generate3 (cont) (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (120 to 330) V (330 to 1020) V (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz 0.55 % + 150 μV 0.27 % + 150 μV 0.091 % + 85 μV 0.091 % + 40 μV 0.19 % + 200 μV 0.26 % + 260 μV 3.6 % + 4 mV 3.6 % + 4 mV 0.55 % + 1.5 mV 0.27 % + 1.5 mV 0.091 % + 500 μV 0.091 % + 500 μV 0.19 % + 2 mV 0.26 % + 2.6 mV 3.6 % + 40 mV 3.6 % + 40 mV 0.55 % + 15 mV 0.27 % + 15 mV 0.091 % + 4 mV 0.091 % + 4 mV 0.21 % + 20 mV 0.27 % + 26 mV 0.55 % + 150 mV 0.27 % + 150 mV 0.091 % + 100 mV 0.21 % + 390 mV 0.28 % + 520 mV 0.55 % + 150 mV 0.27 % + 150 mV 0.091 % + 100 mV Fluke 5540A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 6 of 13 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure3 (5 to 50) V (50 to 500) V (500 to 1000) V (1 to 6) kV (45 to 65) Hz 65 Hz to 10 kHz (10 to 20) kHz (45 to 65) Hz 65 Hz to 10 kHz (45 to 65) Hz 65 Hz to 10 kHz 60 Hz 0.37 % + 0.025 V 0.49 % + 0.025 V 0.85 % + 0.04 V 0.37 % + 0.25 V 0.49 % + 0.25 V 0.37 % + 2.5 V 0.49 % + 2.5 V 1.6 % Fluke 287 Fluke 80K-6 & DMM AC Current – Generate3 (0.12 to 120) μA 120 μA to 1.2 mA (1.2 to 12) mA (12 to 120) mA 120 mA to 1.2 A (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.19 % + 0.02 µA 0.19 % + 0.1 µA 0.19 % + 0.02 µA 0.46 % + 0.15 µA 0.46 % + 1 µA 0.19 % + 0.2 µA 0.19 % + 0.2 µA 0.19 % + 0.2 µA 0.36 % + 0.3 µA 0.46 % + 5 µA 0.19 % + 2 µA 0.19 % + 2 µA 0.19 % + 2 µA 0.19 % + 3 μA 0.46 % + 10 µA 0.19 % + 20 µA 0.19 % + 20 µA 0.19 % + 20 µA 0.19 % + 30 µA 0.46 % + 100 µA 0.19 % + 100 µA 0.19 % + 100 µA 0.19 % + 100 µA 0.22 % + 300 µA 0.46 % + 300 µA Fluke 5540A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 7 of 13 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Current – Generate3 (cont) (1.2 to 3.1) A (3.1 to 12) A (11 to 20.5) A Clamp-On Meters 3 – (10 to 150) A: Toroidal Non-Toroidal (150 to 1025) A: Toroidal Non-Toroidal (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.19 % + 1 mA 0.19 % + 1 mA 0.19 % + 1 mA 0.91 % + 1.5 mA 0.19 % + 2 mA 0.19 % + 2 mA 0.19 % + 2 mA 0.91 % + 4 mA 0.46 % + 50 mA 0.46 % + 50 mA 0.46 % + 50 mA 0.47 % + 0.025 A 1 % + 0.027 A 0.75 % + 0.25 A 1.3 % + 0.25 A 0.64 % + 0.09 A 1.1 % + 0.1 A 0.86 % + 0.9 A 1.4 % + 0.9 A Fluke 5540A Fluke 5540A w/ 5500 coil AC Current – Measure3 (0 to 500) µA 500 µA to 5 mA (5 to 50) mA (50 to 400) mA 400 mA to 5 A (5 to 10) A 45 Hz to 1 kHz 0.74 % + 0.2 µA 0.74 % + 0.5 µA 0.73 % + 0.02 mA 0.73 % + 0.05 mA 0.97 % + 2 mA 0.97 % + 5 mA Fluke 287
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 8 of 13 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples & Measure 3 – Type B Type E Type J Type K Type N Type S Type T (600 to 800) °C (800 to 1820) °C (-250 to -150) °C (-150 to 350) °C (350 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 400) °C 0.40 °C 0.33 °C 0.36 °C 0.18 °C 0.20 °C 0.23 °C 0.17 °C 0.20 °C 0.26 °C 0.20 °C 0.32 °C 0.31 °C 0.19 °C 0.20 °C 0.39 °C 0.31 °C 0.38 °C 0.55 °C 0.22 °C 0.14 °C Fluke 5540A Electrical Calibration of RTD’s3 – Pt 385-100: Measure Simulation (-200 to 100) °C (100 to 800) °C (-200 to 100) °C (100 to 800) °C 0.12 °C 0.26 °C 0.06 °C 0.17 °C Fluke 754 series
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 9 of 13
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 10 of 13 IV. Fluid Quantities Parameter/Equipment Range CMC2, 6, 5 (±) Comments Viscosity Meters3 Up to 100 cP (100 to 1000) cP 0.52 % 0.55 % Standard viscosity solutions w/ bath V. Mechanical Parameter/Equipment Range CMC2, 5, 6, 7 (±) Comments Scales & Balances3 (1 to 500) mg Up to 5 g Up to 10 g Up to 30 g Up to 50 g Up to 100 g Up to 200 g Up to 300 g Up to 500 g Up to 1000 g (> 1 to 11) kg (5 to 10) g (10 to 500) g 501 g to 20 kg (> 20 to 80) kg Up to 1000 lb 0.013 mg + 0.6R 0.043 mg + 0.6R 0.062 mg + 0.6R 0.096 mg + 0.6R 0.17 mg + 0.6R 0.31 mg + 0.6R 0.63 mg + 0.6R 0.92 mg + 0.6R 1.5 mg + 0.6R 3.1 mg + 0.6R 3.1 mg per 1000 g + 0.6R 0.04 % + 0.6R 0.025 % + 0.6R 0.017 % + 0.6R 0.017 % per 20 kg + 0.6R 0.017 % + 0.6R ASTM Class 1 weights (applied load) Class F weights (applied load) Class F weights (applied load) Force3 – Measuring Equipment Up to 1 000 lbf Up to 10 000 lbf 0.017 % + 0.6R 0.014 % of applied load Class F weights Load cell w/ indicator Torque – Measure3 – Wrenches – Click, Dial, Adjustable, Screwdrivers 5 to 1000 lbf∙in 20 to 600 lbf∙ft 0.74 % 0.64 % CDI Suretest 5000- ST
to 1000 cP
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 11 of 13 Parameter/Equipment Range CMC 2, 5, 6, 7 (±) Comments Pressure – Measure & Measuring Equipment3 Pneumatic Hydraulic Up to 300 psig (300 to 3000) psig (5 to 10 000) psig 0.18 psi 1.9 psi 6.4 psi ADT-680 series Atmospheric Pressure – Measure & Measuring Equipment (Vacuum)3 (0.01 to 28.5) in Hg 0.37 in Hg ADT-680 series Speed Measure3 – Optic/Non-Contact: RPM Totalizer/Rate Meters Contact: RPM Totalizer/Rate Meters (6 to 100 000) rpm (2 to 3300) fpm (6 to 20 000) rpm (2 to 3300) fpm 0.017 % 0.017 % 0.21 % 0.21 % Monarch PLT200 Totalize Meters3 – Distance Measure – Mechanical Counter/Totalizers3 Up to 200 ft Up to 999 999 counts 0.63 % (0.02 % + 0.6R) Monarch PLT200 w/ 10 cm wheel
to 3000 psig
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 12 of 13 VI. Thermodynamics Parameter/Equipment Range CMC2, 6, 7 (±) Comments Relative Humidity – Measure3 (10 to 80) % RH 1.3 % RH Rotronic HP32A w/ HC2A-S probe Relative Humidity Measuring Equipment3 (10 to 80) % RH 1.3 % RH Humidity source w/ Rotronic HP32A w/ HC2A-S probe Temperature – Measure3 (-40 to 660) °C 0.051 °C Isotech TTI -10 w/PRT Temperature – Measuring Equipment3 (-25 to 140) °C (50 to 650) °C 0.07 °C 0.15 °C Isotech Hyperion w/ PRT Isotech Jupiter w/PRT Infrared Thermometry – Measuring Equipment3 35 °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.80 °C 0.94 °C 1.2 °C 1.7 °C 2.3 °C Fluke 4181 λ = (8 to 14) µm, where ε = 0.95” VII. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Timers & Stopwatches3 (1 to 3600) s 0.3 s Monarch PLT 200 Frequency – Measuring Equipment3 0.01 Hz to 2 MHz 5.4 ppm + 5 μHz Fluke 5540A ______________________________________________________________ 1 This laboratory offers commercial calibration and field calibration services, where noted.
10 to 80 % RH
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.23) 11/25/2025 Page 13 of 13 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the labor atory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. re solution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as ei ther a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is the numerical value of the resolution of the device. 6 In the statement of CMC, percentages are percent of reading, unless otherwise indicated. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
14

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited CROSS TECHNOLOGIES, INC North Charleston, SC for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this November 25th, 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1741.23 Valid to October 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.