Registers refreshed 2026-11-08.See refresh dates
Sweden

NG Nordic Sweden

Norrtorp, 692 85, Kumla, Sweden

Visit website
SWEDAC a001031-001SWEDAC A001031-001ISO/IEC 17025Register refreshed 2026-11-08

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
10
SWEDAC certificates
2
Site in our directory
1
SWEDAC accredited scope

What this lab is accredited for

Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM D240
ASTM E203
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 14582
EN 27888Water quality - Determination of electrical conductivity
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10523Water quality - Determination of pH
ISO 11465Sludge and solid environmental matrices - Determination of dry residue or water content and calculation of the dry matter fraction on a mass basis
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 17852Water quality - Determination of mercury - Method using atomic fluorescence spectrometry

Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.

Scope as published by SWEDAC

6 lines
SWEDAC

ISO/IEC 17025

Active

a001031-001

View on SWEDAC

Accredited scope, certificate a001031-001

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018 NG Nordic Sweden AB Kumla Ackrediteringsnummer 1099 Laboratoriet A001031-001R; SS-EN 14582:2016 mod/SS- EN ISO 10304-1:2009 mod Bombuppslutning /Jonkromatografi; ISO/IEC 17025:2018 NG Nordic Sweden AB Kumla Ackrediteringsnummer 1099 Laboratoriet A001031-001RÄ TTELSE för gällande beslut daterat 2025-10-17 i ärende 2025/439 Beskrivning: Felaktigt angiven metodreferens för värmevärde är nu borttaget//Daniel Landberg 2025-11-13; ISO 10304-1:2009SludgeSee scope document
2SS-EN ISO 11885:2009 ICP-AES 0; SS-EN ISO 17852:2008; SS-EN ISO 10304-1:2009 Jonkromatografi 0; SS-EN 27888; ISO 11885:2009 ICP-AES 0Sludge0.1 to 99 %
3SS-EN ISO 10523:2012 Elektrod 4; SS-EN ISO 10304-1:2009 Jonkromatografi 0; SS-ISO 11465:1995 Gravimetri 0; SS-EN 1484; ISO 10523:2012 Elektrod 4SewageSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

SWEDAC

ISO/IEC 17025

Active

A001031-001

View on SWEDAC

Accredited scope, certificate A001031-001

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018; SS-EN 14582:2016 mod/SS-EN ISO 10304-1:2009 mod; ASTM D240-2019 modSludgeSee scope document
2ASTM E203-24; SS-EN ISO 11885:2009; SS-EN ISO 17852:2008; SS-EN ISO 10304-1:2009; SS-EN 27888Sludge0.1 to 99 %
3SS-EN ISO 10523:2012; SS-EN ISO 10304-1:2009; SS 028113; SS-ISO 11465:1995; SS-EN 1484; ASTM E203-24SewageSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Norrtorp, Kumla, 692 85, SE

59.29296, 17.22306

Open in Maps

Accreditation data refreshed from the SWEDAC register on .