Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk Nürnberg
Katzwanger Straße 150, 90461, Nürnberg, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk Nürnberg?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-21472-01-00Active
- D-PL-21472-01-01Active
Accredited standards
19Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC
IEC 60156Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
IEC 60247Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
IEC 60422Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
IEC 60450Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 60567Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 60666Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 60814Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 61198Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 61619Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 62021-2Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 62535Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 62697-1Name not checked yet
IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1
IEC 62961Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
EN
EN 12766-1Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
EN 12766-2Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
EN 14210Name not checked yet
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
Other standards
ASTM D7042Name not checked yet
ASTM D 7042; PA3 -042
ISO 2049Petroleum products - Determination of colour (ASTM scale)
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
ISO 12185Crude petroleum, petroleum products and related products - Determination of density - Laboratory density meter with an oscillating U-tube sensor
ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422
Scope as published by DAKKS
5 lines
ISO/IEC 17025
ActiveD-PL-21472-01-00
Accredited scope, certificate D-PL-21472-01-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | - | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-21472-01-01
Accredited scope, certificate D-PL-21472-01-01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | materials | DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001 | insulating liquids especially transformer oil | - |
| 2 | chemical | ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422 | Petroleum products | - |
| 3 | chemical | IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1 | Petroleum products | - |
| 4 | chemical | ASTM D 7042; PA3 -042 | Liquids; liquid Ester | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- ASG Analytik-ServiceNeusäß · ~114 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Petroleum products
- PETROLAB GmbH Laboratorium für Mineralöl- und UmweltanalytikSpeyer · ~193 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Petroleum products
- OELCHECKBrannenburg · ~201 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Petroleum products
- Saybolt-van DuynEssen · ~370 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Petroleum products
- Co-GEM LaborDuisburg · ~383 kmDAKKSShares 2 accredited methods and materialsEN ISO 9001Petroleum products
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.