FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Germany

Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk Nürnberg

Katzwanger Straße 150, 90461, Nürnberg, Germany

DAKKS|D-PL-21472-01-00DAKKS|D-PL-21472-01-01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
2
Scope items
5
Standards
19
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Siemens Energy Global GmbH & Co. KG Materialprüflabor Siemens Trafowerk Nürnberg?

Claim this profile to keep it accurate.

Register record

DAKKSRefreshed
D-PL-21472-01-00Active
D-PL-21472-01-01Active

Accredited standards

19

Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC

IEC 60156Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

IEC 60247Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

IEC 60422Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

IEC 60450Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 60567Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 60666Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 60814Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 61198Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 61619Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 62021-2Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 62535Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 62697-1Name not checked yet
As written on the certificate · Line 3 (DAKKS D-PL-21472-01-01)

IEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1

IEC 62961Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

EN

EN 12766-1Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

EN 12766-2Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

EN 14210Name not checked yet
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

Other standards

ASTM D7042Name not checked yet
As written on the certificate · Line 4 (DAKKS D-PL-21472-01-01)

ASTM D 7042; PA3 -042

ISO 2049Petroleum products - Determination of colour (ASTM scale)
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

ISO 12185Crude petroleum, petroleum products and related products - Determination of density - Laboratory density meter with an oscillating U-tube sensor
As written on the certificate · Line 2 (DAKKS D-PL-21472-01-01)

ISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422

Scope as published by DAKKS

5 lines
DAKKS

ISO/IEC 17025

Active

D-PL-21472-01-00

View scope

Accredited scope, certificate D-PL-21472-01-00

LineDisciplineMethodMatrixRange
1-DIN EN ISO/IEC 17025:2018; DIN EN ISO 9001--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

DAKKS

ISO/IEC 17025

Active

D-PL-21472-01-01

View scope

Accredited scope, certificate D-PL-21472-01-01

LineDisciplineMethodMatrixRange
1materialsDIN EN ISO/IEC 17025:2018; DIN EN ISO 9001insulating liquids especially transformer oil-
2chemicalISO 2049; ISO 12185; DIN EN 12766 -1; DIN EN 12766 -2; DIN EN 14210; IEC 62961; IEC 60156; IEC 60247; IEC 60422Petroleum products-
3chemicalIEC 60450; IEC 60567; IEC 60666; IEC 60814; IEC 61198; IEC 61619; IEC 62021 -2; IEC 62535; IEC 62697 -1Petroleum products-
4chemicalASTM D 7042; PA3 -042Liquids; liquid Ester-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Katzwanger Straße 150, Nürnberg, 90461, DE

49.42332, 11.08486

Open in Maps

Accreditation data refreshed from the DAKKS register on .