Canadian Instrumentation Services Group
Peterborough, Canada
Visit website- Scope lines
- 23
- A2LA certificate
- 1
- Sites in our directory
- 4
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 23 scope lines.
A2LA certificate 3023.01 · 23 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | - | DC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 2 of 22
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
DC Voltage – Measure,
High Voltage3
(0.001 00 to 1.0000) kV
(1.0001 to 4.4662) kV
(4.4663 to 5.2558) kV
(5.2559 to 5.9095) kV
(5.9096 to 6.4837) kV
(6.4838 to 7.0035) kV
(7.0036 to 7.4826) kV
(7.4827 to 7.9298) kV
(7.9299 to 8.3510) kV
(8.3511 to 8.7504) kV
(8.7505 to 9.1313) kV
(9.1314 to 9.4959) kV
(9.4960 to 9.8464) kV
(9.8465 to 10.1843) kV
(10.1844 to 10.5108) kV
(10.5109 to 10.8272) kV
(10.8273 to 11.1342) kV
(11.1342 to 11.4328) kV
(11.4329 to 11.7235) kV
(11.7236 to 12.0069) kV
(12.0070 to 12.2837) kV
(12.2837 to 12.5542) kV
(12.5543 to 12.8189) kV
(12.8190 to 13.0781) kV
(13.0782 to 13.3322) kV
(13.3323 to 13.5815) kV
(13.5816 to 13.8261) kV
(13.8262 to 14.0665) kV
(14.0666 to 14.3027) kV
(14.3028 to 14.5351) kV
(14.5352 to 14.7637) kV
(14.7638 to 14.9888) kV
(14.9889 to 15.0000) kV
(15 to 20) kV
(15 000 to 29 880.7) V
(29 880.8 to 40 089.1) V
(40 089.2 to 48 181.2) V
(48 181.3 to 55 097.3) V
(55 097.4 to 61 237.2) V
(61 237.3 to 66 815.3) V
(66 815.4 to 70 000.0) V
(71 to 100) kV
0.023 % + 0.04 V
0.026 % + 0.04 V
0.027 % + 0.04 V
0.028 % + 0.04 V
0.029 % + 0.04 V
0.030 % + 0.04 V
0.031 % + 0.04 V
0.032 % + 0.04 V
0.033 % + 0.04 V
0.034 % + 0.04 V
0.035 % + 0.04 V
0.036 % + 0.04 V
0.037 % + 0.04 V
0.038 % + 0.04 V
0.039 % + 0.04 V
0.040 % + 0.04 V
0.041 % + 0.04 V
0.042 % + 0.04 V
0.043 % + 0.04 V
0.044 % + 0.04 V
0.045 % + 0.04 V
0.046 % + 0.04 V
0.047 % + 0.04 V
0.048 % + 0.04 V
0.049 % + 0.04 V
0.050 % + 0.04 V
0.051 % + 0.04 V
0.052 % + 0.04 V
0.053 % + 0.04 V
0.054 % + 0.04 V
0.055 % + 0.04 V
0.056 % + 0.04 V
0.056 % + 0.04 V
0.22 % + 4.0 V
0.03 % + 0.25 V
0.04 % + 0.25 V
0.05 % + 0.25 V
0.06 % + 0.25 V
0.07 % + 0.25 V
0.08 % + 0.25 V
0.09 % + 0.25 V
0.10 %
Vitrek 4700
Vitrek 4600A
Vitrek 4700A/HVL-70
Phenix DVD100 with
Keysight 34401A | See scope document |
| 3 | - | DC Current; DC ResistanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 3 of 22
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Current – Generate3
Clamp-On –
Non-Toroidal3
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 3.0) A
(3 to 11) A
(11 to 20) A
(20 to 100) A
(2.2 to 3.1) A
(11 to 12) A
(11 to 20) A
(20 to 150) A
(150 to 1000) A
33 μA/A + 5.4 nA
27 μA/A + 6.2 nA
27 μA/A + 39 nA
35 μA/A + 0.62 μA
54 μA/A + 12 μA
0.023 % + 32 μA
0.026 % + 0.37 mA
0.062 % + 0.58 mA
0.020 % + 21 mA
0.027 % + 14 μA
0.029 % + 0.23 mA
0.068 % + 0.47 mA
0.50 % + 0.14 A
0.50 % + 0.50 A
Fluke 5730A
Fluke 5520
Fluke 5725A
Fluke 5520
Ballantine 1620A with
Fluke 5520
Fluke 5550A
Fluke 5520A with 50
turn coil
DC Current – Measure3
Up to 200 μA
200 μA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
Up to 10 μA
(10 to 100) μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 10) A
(10 to 30) A
(21 to 100) A
(101 to 300) A
12 μA/A + 0.31 nA
12 μA/A + 3.1 nA
12 μA/A + 31 nA
35 μA/A + 0.62 μA
0.016 % + 12 μA
0.035 % + 0.31 mA
24 μA/A + 0.4 nA
8.5 μA/A + 0.39 nA
7.8 μA/A + 3.9 nA
8.5 μA/A + 39 nA
33 μA/A + 1 μA
0.01 % + 100 μA
0.017 % + 0.4 mA
0.049 % + 4.4 mA
0.040 % + 0.7 mA
0.040 % + 0.7 mA
Fluke 8508A
Fluke 8588A
HP 34401 with L&N
shunts
DC Resistance –
Generate, Fixed Points3
(0 to 12) Ω
(12 to 120) Ω
(0.12 to 1.2) kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
(0.12 to 1.2) MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
(120 to 1200) MΩ
25 μΩ/Ω + 0.78 mΩ
19 μΩ/Ω + 0.8 mΩ
17 μΩ/Ω + 1.6 mΩ
17 μΩ/Ω + 16 mΩ
17 μΩ/Ω + 0.16 Ω
19 μΩ/Ω + 1.6 Ω
30 μΩ/Ω + 31 Ω
310 μΩ/Ω + 1.9 kΩ
0.4 % + 0.8 MΩ
Fluke 5550A | - |
| 4 | - | DC ResistanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 4 of 22
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Resistance –
Generate, Fixed Points3
(cont)
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
74 μΩ/Ω
19 μΩ/Ω
19 μΩ/Ω
8.5 μΩ/Ω
8.5 μΩ/Ω
5.6 μΩ/Ω
5.6 μΩ/Ω
5.4 μΩ/Ω
5.4 μΩ/Ω
6.2 μΩ/Ω
7.8 μΩ/Ω
11 μΩ/Ω
13 μΩ/Ω
29 μΩ/Ω
36 μΩ/Ω
85 μΩ/Ω
Fluke 5730A
DC Resistance –
Generate3
Fixed Points3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(0.11 to 0.33) kΩ
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11.0) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.330 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
0.001 Ω
0.0019 Ω
0.01 Ω
0.019 Ω
0.1 Ω
0.19 Ω
1.0 Ω
1.9 Ω
19 Ω
190 Ω
1.9 kΩ
19 kΩ
27 μΩ/Ω + 0.78 mΩ
19 μΩ/Ω + 1.2 mΩ
17 μΩ/Ω + 1.1 mΩ
17 μΩ/Ω + 1.6 mΩ
17 μΩ/Ω + 1.6 mΩ
17 μΩ/Ω + 16 mΩ
17 μΩ/Ω + 16 mΩ
17 μΩ/Ω + 0.16 Ω
17 μΩ/Ω + 0.16 Ω
19 μΩ/Ω + 1.6 Ω
19 μΩ/Ω + 1.6 Ω
33 μΩ/Ω + 23 Ω
85 μΩ/Ω + 39 Ω
0.016 % + 1.9 kΩ
0.031 % + 2.3 kΩ
0.19 % + 78 kΩ
0.93 % + 0.39 MΩ
58 µΩ/Ω
210 µΩ/Ω
23 µΩ/Ω
110 µΩ/Ω
23 µΩ/Ω
61 µΩ/Ω
61 µΩ/Ω
21 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
Fluke 5520A
YEW 2792 resistor
IET labs resistor
YEW 2792 resistor
IET labs resistor
YEW 2792 resistor
IET labs resistor
ESI-SR1 resistor
IET labs resistor | See scope document |
| 5 | - | DC Resistance; DC PowerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 5 of 22
Parameter/Equipment
Range
CMC2, 4, 5, 6 (±)
Comments
DC Resistance –
Generate3 (cont)
Fixed Points3
500 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
0.5 %
1.0 %
1.0 %
1.0 %
5.0 %
CISG fixed resistor
DC Resistance –
Measure3
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 1 GΩ
Up to 1 Ω
(1 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
(1.1 to 10) GΩ
(10.1 to 100) GΩ
101 GΩ to 1 TΩ
15 μΩ/Ω + 3.9 μΩ
8.9 μΩ/Ω + 14 μΩ
7.4 μΩ/Ω + 47 μΩ
7.4 μΩ/Ω + 0.47 mΩ
7.4 μΩ/Ω + 4.7 mΩ
7.4 μΩ/Ω + 47 mΩ
8.1 μΩ/Ω + 0.93 Ω
15 μΩ/Ω + 9.3 Ω
58 μΩ/Ω + 0.93 kΩ
0.015 % + 93 kΩ
11 μΩ/Ω + 4.0 μΩ
7.7 μΩ/Ω + 14 μΩ
7.1 μΩ/Ω + 47 μΩ
7.1 μΩ/Ω + 0.47 mΩ
7.1 μΩ/Ω + 4.7 mΩ
7.3 μΩ/Ω + 47 mΩ
8.2 μΩ/Ω + 1 Ω
11 μΩ/Ω + 100 Ω
39 μΩ/Ω + 10 kΩ
0.015 % + 100 kΩ
0.071 %
0.10 %
0.20 %
Fluke 8508A
High voltage mode
Fluke 8588A
Fluke 8588A HV
Mode
Guildline 6500A
DC Power – Generate3
(1 to 504) V
(0.1 to 10) A
390 μW/W
Fluke 6105A | See scope document |
| 6 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 6 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage –
Generate3
(1 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.021 % + 3.9 μV
0.0081 % + 3.9 μV
0.0070 % + 3.9 μV
0.018 % + 3.9 μV
0.042 % + 4.7 μV
0.093 % + 9.3 μV
0.17 % + 19 μV
0.24 % + 19 μV
0.021 % + 3.9 µV
0.0081 % + 3.9 μV
0.0070 % + 3.9 μV
0.018 % + 3.9 μV
0.042 % + 4.7 μV
0.093 % + 9.3 μV
0.12 % + 19 μV
0.24 % + 19 μV
0.021 % + 12 μV
81 μV/V + 6.2 μV
53 μV/V + 6.2 μV
0.011 % + 6.2 μV
0.029 % + 16 μV
0.054 % + 19 μV
0.12 % + 23 μV
0.22 % + 47 μV
0.021 % + 39 μV
78 μV/V + 16 μV
36 μV/V + 7.8 μV
60 μV/V + 9.3 μV
75 μV/V + 31 μV
0.029 % + 78 μV
0.085 % + 0.19 mV
0.07 % + 0.47 mV
Fluke 5730A | See scope document |
| 7 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 7 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Generate3
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
750 V
1100 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
50 Hz to 1 kHz
(30 to 50) kHz
(50 to 100) kHz
(1 to 20) kHz
(20 to 30) kHz
0.021 % + 0.39 mV
78 μV/V + 0.16 mV
36 μV/V + 55 μV
60 μV/V + 93 μV
75 μV/V + 0.19 mV
0.022 % + 0.62 mV
0.085 % + 1.9 mV
0.12 % + 3.1 mV
0.021 % + 3.9 mV
80 μV/V + 1.6 mV
46 μV/V + 0.55 mV
74 μV/V + 0.93 mV
0.013 % + 2.3 mV
58 μV/V + 3.1 mV
0.028 % + 8.5 mV
0.10 % + 35 mV
97 μV/V + 4.7 mV
0.028 % + 8.5 mV
Fluke 5730A
Fluke 5725A
AC Voltage – Measure3
Up to 200 mV
200 mV to 2 V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.016 % + 12 μV
0.012 % + 3.9 μV
98 μV/V + 3.9 μV
0.010 % + 1.9 μV
99 μV/V + 3.9 μV
0.027 % + 7.8 μV
0.059 % + 19 μV
0.015 % + 0.11 mV
96 μV/V + 19 μV
77 μV/V + 19 μV
59 μV/V + 19 μV
75 μV/V + 19 μV
0.019 % + 39 μV
0.043 % + 0.19 mV
0.24 % + 1.9 mV
0.78 % + 19 mV
Fluke 8508A | See scope document |
| 8 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 8 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure3
(cont)
(2 to 20) V
(20 to 200) V
(200 to 1000) V
Up to 10 mV
(10 to 100) mV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
0.015 % + 1.1 mV
96 μV/V + 0.19 mV
76 μV/V + 0.19 mV
59 μV/V + 0.19 mV
75 μV/V + 0.19 mV
0.019 % + 0.39 mV
0.043 % + 1.9 mV
0.24 % + 19 mV
0.78 % + 0.19 V
0.014 % + 11 mV
93 μV/V + 1.9 mV
74 μV/V + 1.9 mV
58 μV/V + 1.9 mV
74 μV/V + 1.9 mV
0.019 % + 3.9 mV
0.043 % + 19 mV
0.23 % + 19 mV
0.78 % + 0.19 V
0.014 % + 65 mV
0.010 % + 20 mV
85 μV/V + 20 mV
0.019 % + 41 mV
0.048 % + 0.20 V
0.025 % + 1.1 μV
0.033 % + 1.1 μV
0.034 % + 1.1 μV
0.3 % + 0.8 μV
1 % + 3.8 μV
2 % + 3.8 μV
68 μV/V + 0.5 μV
0.011 % + 0.5 μV
0.021 % + 1 μV
0.051 % + 5 μV
0.2 % + 31 μV
1 % + 100 μV
1.5 % + 500 μV
4 % + 1 mV
8 % + 1 mV
15 % + 1 mV
Fluke 8508A
Fluke 8588A | See scope document |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 9 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure3
(cont)
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
64 μV/V + 5.0 μV
0.011 % + 5.0 μV
0.021 % + 10 μV
0.051 % + 50 μV
0.2 % + 310 μV
1 % + 1 mV
1.5 % + 5 mV
4 % + 10 mV
8 % + 10 mV
15 % + 10 mV
64 μV/V + 50 μV
0.011 % + 50 μV
0.021 % + 100 μV
0.051 % + 500 μV
0.2 % + 3.1 mV
1 % + 10 mV
1.5 % + 50 mV
4 % + 100 mV
8 % + 100 mV
15 % + 100 mV
70 μV/V + 0.50 mV
90 μV/V + 0.50 mV
0.021 % + 1 mV
0.051 % + 5 mV
0.35 % + 47 mV
1 % + 500 mV
90 μV/V + 25 mV
0.021 % + 25 mV
0.051 % + 100 mV
Fluke 8588A
AC Voltage Ratio3 –
(0.000 05 to 1)
(20 000 to 1)
60 Hz
0.006 % of Ratio
ESI 73 | ||
| 10 | - | AC Voltage; AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 10 of 22
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
AC Voltage – Measure
High Voltage3
(10 to 1000) V
(1000.1 to 8165.5) V
(8165.6 to 10 000.0) V
(10 to 15) kV
(15 to 20) kV
(100 to 26 726.1) V
(26 726.2 to 37 796.4) V
(37 796.5 to 46 291.0) V
(46 291.1 to 50 000.0) V
(50 to 100) kV
(30 to 200) Hz
(30 to 200) Hz
(30 to 200) Hz
(20 to 100) Hz
60 Hz
(30 to 100) Hz
(30 to 100) Hz
(30 to 100) Hz
(30 to 100) Hz
60 Hz
0.10 % + 0.02 V
0.10 % + 0.15 V
0.11 % + 0.15 V
0.49 % + 20 V
0.28 %
0.08 % + 0.45 V
0.09 % + 0.45 V
0.10 % + 0.45 V
0.11 % + 0.45 V
0.28 %
Vitrek 4700
Vitrek 4600A
Hipotronics KVM20
with Keysight 34401
Vitrek 4700A with
HLV-70
Phenix DVD100 with
Keysight 34401A
AC Current – Generate3
(2.2 to 3.1) A
(11 to 12) A
(12 to 30) A
Up to 220 μA
220 μA to 2.2 mA
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(3 to 45) Hz
(45 to 1000) Hz
(1 to 5) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.07 % + 34 μA
0.047 % + 35 μA
0.07 % + 0.35 mA
0.4 % + 0.8 mA
0.093 % + 0.9 mA
0.074 % + 0.5 mA
0.093 % + 0.9 mA
0.37 % + 0.9 mA
0.062 % + 9.3 mA
0.043 % + 7.4 mA
0.31 % + 9.3 mA
0.022 % + 16 nA
0.014 % + 9.3 nA
0.009 % + 7.8 nA
0.025 % + 12 nA
0.085 % + 62 nA
0.022 % + 39 nA
0.014 % + 32 nA
0.009 % + 32 nA
0.017 % + 0.10 µA
0.085 % + 0.62 µA
Fluke 5550A
Fluke 5730A | See scope document |
| 11 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 11 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Generate3
(cont)
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 3) A
(3 to 11) A
(11 to 20) A
(20 to 100) A
Clamp-On Toroidal
Type3:
(20 to 150) A
(150 to 1000) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(100 to 1000) Hz
(1 to 5) kHz
(45 to 1000) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.022 % + 0.39 µA
0.014 % + 0.32 µA
0.009 % + 0.32 µA
0.017 % + 0.55 µA
0.085 % + 4.7 μA
0.022 % + 3.9 μA
0.014 % + 3.2 μA
0.009 % + 2.4 μA
0.39 % + 0.78 mA
0.085 % + 9.3 μA
0.022 % + 32 μA
0.036 % + 78 μA
0.54 % + 0.16 mA
0.12 % + 78 μA
0.039 % + 78 μA
0.039 % + 0.78 mA
1.6 % + 3.9 mA
0.031 % + 0.13 mA
0.066 % + 0.29 mA
0.26 % + 0.58 mA
0.078 % + 3.9 mA
0.10 % + 3.9 mA
1.9 % + 3.9 mA
0.18 % + 0.10 A
0.30 % + 25 mA
0.80 % + 27 mA
0.27 % + 0.12 A
0.78 % + 0.13 A
Fluke 5730A
Fluke 5520A
Fluke 5725A
Fluke 5520A
Ballantine 1620 /
Fluke 5520
Fluke 5520A with 50
turn coil | See scope document |
| 12 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 12 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Generate3
(cont)
Clamp-On Non-Torodal
Type3:
(20 to 150) A
(150 to 1000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.57 % + 0.25 A
1.0 % + 0.25 A
0.55 % + 0.30 A
1.0 % + 0.90 A
Fluke 5520A with 50
turn coil
AC Current – Measure3
Up to 200 μA
200 μA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(21 to 100) A
Up to 10 μA
10 to 100 μA
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
Up to 1 kHz
1 Hz to 30 kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 300) kHz
0.046 % + 19 nA
0.046 % + 19 nA
0.060 % + 19 nA
0.31 % + 19 nA
0.029 % + 0.19 μA
0.026 % + 0.19 μA
0.060 % + 0.19 μA
0.31 % + 0.19 μA
0.029 % + 1.9 μA
0.026 % + 1.9 μA
0.060 % + 1.9 μA
0.31 % + 1.9 μA
0.029 % + 19 μA
0.024 % + 19 μA
0.054 % + 19 μA
0.055 % + 0.19 mA
0.063 % + 0.19 mA
0.23 % + 0.19 mA
0.070 % + 1.9 mA
0.19 % + 1.9 mA
0.10 % + 2 mA
0.20 % + 2.5 nA
0.026 % + 5.0 nA
0.051 % + 5.0 nA
0.072 % + 5.0 nA
0.40 % + 10 nA
Fluke 8508A
Fluke 8508A/VS2575
Fluke 8588A | - |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 13 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Current – Measure3
(cont)
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 10) A
(10 to 30) A
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 300) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 300) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 10 kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.026 % + 0.05 μA
0.051 % + 0.05 μA
0.072 % + 0.05 μA
0.40 % + 0.10 μA
0.026 % + 0.50 μA
0.051 % + 0.50 μA
0.072 % + 0.50 μA
0.40 % + 1 μA
0.026 % + 5.0 μA
0.05 % + 5.0 μA
0.07 % + 5.0 μA
0.026 % + 0.10 mA
0.051 % + 0.10 mA
0.071 % + 0.10 mA
0.08 % + 0.50 mA
0.08 % + 12 mA
0.12 % + 12 mA
Fluke 8588A
Capacitance – Generate3
(0 to 1.2) nF
(1.2 to 12) nF
(12 to 120) nF
(0.12 to 1.2) μF
(1.2 to 12) μF
(12 to 120) μF
(0.12 to 1.2) mF
(1.2 to 12) mF
(12 to 120) mF
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) μF
(1.1 to 3.3) μF
100 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 1.3 kHz
(2 to 310) Hz
(0.5 to 110) Hz
(0.5 to 40) Hz
(0.1 to 11) Hz
(0.03 to 4) Hz
(0.01 to 1.3) Hz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
0.15 % + 2.7 pF
0.15 % + 7.8 pF
0.12 % + 39 pF
0.12 % + 0.39 nF
0.12 % + 3.9 nF
0.12 % + 39 nF
0.28 % + 0.39 µF
0.28 % + 3.9 µF
0.62 % + 39 µF
0.29 % + 7.8 pF
0.29 % + 7.8 pF
0.29 % + 7.8 pF
0.15 % + 7.8 pF
0.15 % + 78 pF
0.15 % + 78 pF
0.15 % + 0.23 nF
0.15 % + 0.78 nF
0.15 % + 2.3 nF
Fluke 5550A
Fluke 5520A | ||
| 14 | - | CapacitanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 14 of 22
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
Capacitance – Generate3
(cont)
(3.3 to 11) μF
(11 to 33) μF
(33 to 110) μF
(110 to 330) μF
(0.33 to 1.1) mF
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
Up to 50 Hz
Up to 20 Hz
0.29 % + 7.8 pF
0.23 % + 23 nF
0.26 % + 78 nF
0.26 % + 0.23 µF
0.26 % + 0.78 µF
Fluke 5520A
Capacitance – Generate,
Fixed Values3
100 pF
1 nF
10 nF
100 nF
1 μF
10 μF
100 μF
900 μF
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz
100 Hz
50 Hz
0.10 %
0.054 %
0.054 %
0.054 %
0.054 %
0.064 %
0.20 %
0.22 %
GR 1409
CRC X93X106
CRC X93X107
CISG-900 μF
Capacitance – Measure3
Up to 6400 pF
(6.4 to 100) nF
(100 to 1600) nF
(1.6 to 25) μF
Up to 6400 pF
(6.4 to 100) nF
(100 to 1600) nF
(1.6 to 25) μF
Up to 6400 pF
(6.4 to 100) nF
(100 to 1600) nF
(1.6 to 25) μF
Up to 6400 pF
(6.4 to 100) nF
(100 to 1600) nF
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz
100 Hz
100 Hz
100 Hz
10 kHz
10 kHz
10 kHz
10 kHz
20 kHz
100 kHz
100 kHz
0.020 %
0.021 %
0.020 %
0.021 %
0.040 %
0.040 %
0.040 %
0.040 %
0.050 %
0.050 %
0.050 %
0.41 %
0.070 %
0.32 %
0.32 %
GR 1689 RLC
Digibridge | - |
| 15 | - | Fixed inductorsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 15 of 22
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
Inductance – Generate3
(13 to 120) µH
(0.12 to 1.2) mH
(1.2 to 12) mH
(12 to 120) mH
(0.12 to 1.2) H
(1.2 to 12) H
(12 to 120) H
100 µH
1 mH
10 mH
100 mH
1 H
10 H
1 kHz
1 kHz
110 Hz
100 Hz
10 Hz
3 Hz
2 Hz
10 kHz
1 kHz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
0.21 % + 19 nH
0.14 % + 0.9 µH
0.14 % + 9.3 µH
0.14 % + 93 µH
0.18 % + 0.9 mH
0.21 % + 9.3 mH
0.28 % + 93 mH
0.053 %
0.11 %
0.026 %
0.31 %
0.023 %
0.042 %
0.024 %
0.042 %
0.023 %
0.042 %
0.024 %
0.042 %
Fluke 5550A
Fixed inductors
GR 1482 series
Phase – Measure3
(0 to 360)°
10 mV to 630 V
5 Hz to <2 kHz
(2 to 5) kHz
(>5 to 10) kHz
(>10 to 50) kHz
0.021°
0.033°
0.042°
0.052°
Clarke-Hess 6000
Inductance – Measure3
(4.1 to 65) H
(256 to 4100) mH
(16 to 256) mH
(1 to 16) mH
100 uH
(4.1 to 65) H
(256 to 4100) mH
(16 to 256) mH
(1 to 16) mH
(4.1 to 65) H
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz
100 Hz
100 Hz
100 Hz
10 kHz
0.023 %
0.023 %
0.023 %
0.023 %
0.11 %
0.11 %
0.042 %
0.042 %
0.042 %
1.6 %
GR 1689 RLC
Digibridge | - |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 16 of 22
Parameter/Range
Frequency
CMC2, 4, 5, 6 (±)
Comments
Inductance – Measure3
(cont)
(256 to 4100) mH
(16 to 256) mH
(0.1 to 16) mH
(0.1 to 16) mH
10 kHz
10 kHz
10 kHz
100 kHz
0.17 %
0.052 %
0.052 %
0.32 %
GR 1689 RLC
Digibridge
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Electrical Simulation of
Thermocouple Devices –
Generate & Measure3
Type E
Type J
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-250 to -150) °C
(-150 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1200) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.29 °C
0.093 °C
0.078 °C
0.093 °C
0.12 °C
0.25 °C
0.078 °C
0.07 °C
0.10 °C
0.12 °C
0.16 °C
0.093 °C
0.078 °C
0.10 °C
0.14 °C
0.15 °C
0.078 °C
0.07 °C
0.085 °C
0.12 °C
Fluke 5520A
Fluke 5550A
Fluke 5520A
Fluke 5550A | ||
| 17 | - | thermocouple devicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 17 of 22
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Electrical Simulation of
Thermocouple Devices –
Generate & Measure3
(cont)
Type K
Type N
Type R
Type S
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
0.19 °C
0.11 °C
0.093 °C
0.15 °C
0.23 °C
0.17 °C
0.078 °C
0.07 °C
0.13 °C
0.22 °C
0.23 °C
0.13 °C
0.12 °C
0.11 °C
0.16 °C
0.20 °C
0.093 °C
0.078 °C
0.07 °C
0.12 °C
0.37 °C
0.22 °C
0.20 °C
0.23 °C
0.32 °C
0.18 °C
0.17 °C
0.21 °C
0.36 °C
0.23 °C
0.22 °C
0.26 °C
0.26 °C
0.19 °C
0.20 °C
0.26 °C
Fluke 5520A
Fluke 5550A
Fluke 5520A
Fluke 5550A
Fluke 5520A
Fluke 5550A
Fluke 5520A
Fluke 5550A | See scope document |
| 18 | - | Thermocouple Devices; RTD Indicators & Indicating SystemsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 18 of 22
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Electrical Simulation of
Thermocouple Devices –
Generate & Measure3
(cont)
Type T
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.37 °C
0.14 °C
0.093 °C
0.078 °C
0.37 °C
0.13 °C
0.078 °C
0.07 °C
Fluke 5520A
Fluke 5550A
Electrical Simulation of
RTD Indicators &
Indicating Systems3 –
Generate
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.031 °C
0.039 °C
0.054 °C
0.062 °C
0.070 °C
0.078 °C
0.16 °C
0.039 °C
0.039 °C
0.047 °C
0.062 °C
0.070 °C
0.085 °C
0.15 °C
Fluke 5520A
Fluke 5550A | See scope document |
| 19 | - | DC Signal Output; Square Wave Output; Leveled Sine Wave; Leveled Sine Flatness; Time MarkerShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 19 of 22
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Oscilloscopes3 –
DC Signal Output
50 Ω Load
1 MΩ Load
50 Ω Load
1 MΩ Load
Square Wave Output –
V(p-p)
50 Ω Load
1 MΩ Load
50 Ω Load
1 MΩ Load
Leveled Sine Wave (Into
50 Ω) – V(p-p)
5 mV to 5.5 V
5 mV to 5.5 V
Leveled Sine Flatness
(50 kHz Reference)
5 mV to 5.5 V
5 mV to 5.5 V
5 mV to 3.5 V
Time Marker
(50 Ω Load)
(-6 to 6) V
(-130 to 130) V
(-6 to 6.6) V
(-120 to 120) V
1 mV to 6.6 V
1 mV to 130 V
1 mV to 6.6 V
1 mV to 120 V
50 kHz Reference
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
50 kHz to 10 MHz
(10 to 600) MHz
(600 to 1100) MHz
2 ns to 5 s
0.19 % + 31 μV
0.039 % + 31 μV
0.19 % + 31 μV
0.039 % + 31 μV
0.19 % + 31 μV
0.078 % + 31 μV
0.19 % + 31 μV
0.078 % + 31 μV
1.6 % + 0.23 mV
1.6 % + 0.23 mV
1.2 % + 78 μV
1.6 % + 78 μV
3.1 % + 78 μV
1.2 % + 78 μV
2.3 % + 78 μV
3.1 % + 78 μV
1.9 μs/s
Fluke 5520A/SC600
Fluke
5550A/SC1100
Fluke 5520A/SC600
Fluke
5550A/SC1100
Fluke 5520A/SC600
Fluke
5550A/SC1100
Fluke 5520A/SC600
Fluke
5550A/SC1100
Fluke
5550A/SC1100 | See scope document |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 20 of 22
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Power3 – Generate
0.5 = < PF < =1
(1.0 to 1008) V
(0.1 to 50) A
(16 to 850) Hz
67 μW/W
Fluke 6105A
II. Electrical – Microwave/RF
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
RF Power – Generate3
(-48 to 24) dBm
(-74 to -48) dBm
(-94 to -74) dBm
(-48 to 20) dBm
(-17 to 20) dBm
(-74 to -17) dBm
(-17 to 20) dBm
(-94 to -74) dBm
(-130 to -94) dBm
10 Hz to 125 MHz
100 kHz to 125 MHz
100 kHz to 300 MHz
(125 to 300) MHz
300 MHz to 1.4 GHz
300 MHz to 4 GHz
(3 to 4) GHz
300 MHz to 4 GHz
10 MHz to 3 GHz
0.039 dBm
0.16 dBm
0.39 dBm
0.078 dBm
0.39 dBm
0.78 dBm
0.39 dBm
0.39 dBm
1.2 dBm
Fluke 9640A with
Fluke 9640A-50 head
III. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Pressure – Pneumatic
Pressure/Vacuum Gauges
& Tools3
(-15 to 0) lb/in2
(0 to 3.6) lb/in2
(0 to 5) lb/in2
(0 to 15) lb/in2
(0 to 30) lb/in2
(0 to 100) lb/in2
(0 to 200) lb/in2
(0 to 300) lb/in2
(0 to 600) lb/in2
(0 to 1000) lb/in2
(0 to 2500) lb/in2
(-100 to 200) kPa
0.029 kPa
0.007 kPa
0.011 kPa
0.029 kPa
0.056 kPa
0.21 kPa
0.38 kPa
0.56 kPa
1.1 kPa
2.1 kPa
4.4 kPa
0.02 kPa
Heise ST-2H digital
indicator with
HQS-2 module
HQS-1 module
HQS-2 module
Fluke PM500-BG200K | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 21 of 22
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Pressure – Pneumatic
Pressure/Vacuum
Gauges & Tools3
(-100 to 1000) kPa
(1001 to 2000) kPa
(-100 to 2000) kPa
(2001 to 4000) kPa
(-100 to 5000) kPa
(5001 to 10 000) kPa
(-100 to 10 000) kPa
(10 001 to 20 000) kPa
0.1 kPa
0.01 %
0.2 kPa
0.01 %
0.5 kPa
0.01 %
1.0 kPa
0.01 %
Fluke
PM500-BG2M
Fluke
PM500-BG4M
Fluke
PM500-BG10M
Fluke
PM500-BG20M
Torque – Torque
Wrenches & Tools3
(5 to 50) lbf·in
(40 to 400) lbf·in
(100 to 1000) lbf·in
(25 to 250) lbf·ft
(60 to 600) lbf·ft
(100 to 1000) lbf·ft
0.28 %
0.28 %
0.28 %
0.28 %
0.28 %
0.28 %
CDI 5000-ST with
CDI 2000-400-02
4 in 1 transducer
CDI 5000-ST with
CDI 2000-12-02
CDI 5000-ST with
CDI 2000-13-02
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Frequency –
Measure3
Up to 3 GHz
0.18 µHz/Hz
HP53132 OPT.010
Frequency –
Generate3
10 MHz
Up to 80 MHz
80 MHz to 4 GHz
6 x 10-12 Hz
2.0 µHz/Hz
0.031 µHz/Hz + 0.12 mHz
HP 58503B / GPS
HP33250A
Fluke 9640
________________________________________
1 This laboratory offers commercial calibration service and field calibration service. | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3023.01) 05/14/2026 Page 22 of 22
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
5 In the statement of CMC, the value is defined as the percentage of the reading unless otherwise indicated.
6 In the statement of CMC, the resolution and repeatability of the unit under test is not taken into account.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 23 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
3 other sites in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.