Poland
TESMO Sp. z o.o.
ul. Rzeczna 10, 03-794, Warszawa, Poland
PCA|AB 872ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
6
Locations
1
Contact this laboratory
Register record
- PCACollected
- AB 872Active
Certificates and scope
1PCA
ISO/IEC 17025
ActiveAB 872
Accredited scope, certificate AB 872
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| chemical | PN-ISO 10396:2001; PN-EN 12619:2013-05; PN-EN 14790:2017-04; PN-EN 1948-1:2006; PN-EN 13649:2005; PN-EN 1911:2011; PN-EN 13211+AC:2006; PN-Z-04008-4:1999; ISO 15713:2006; PN-EN 14385:2005 | Flue gas | 0.2 to 25 % |
| chemical | PN-EN ISO 21877:2020-03; PN-EN ISO 21258:2010; PN-Z-04030-7:1994; PN-EN 14385:2005; PN-EN 1948-4+A1:2014-3; PN-EN 1948-1:2006 | Flue gas | 1 to 400 mg/m3 |
| chemical | - | waste gases; general environment (physical factors – noise); air protection equipment; automatic monitoring systems (AMS) | - |
| environmental | PN-Z-04030-7:1994; PN-EN 16911:2013-07; PN-EN 13284-1:2018-02; PN-ISO 10396:2001; PN-EN 14792:2017-04; PN-EN 14791:2017-04; PN-EN 14789:2017-04; PN-EN 15058:2017-04 | Flue gas | 0.001 to 2500 g/m3; mg/m3; %; m/s |
| environmental | PN-EN 14181:2015-02; PN-EN ISO 21877:2020-03; PN-EN ISO 21258:2010; PN-EN 13211+AC:2006; PN-87/M-34129; PN-Z-04030-7:1994; Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. 2023 poz. 1706) | Automatyczne Systemy Monitoringu (AMS); Urządzenia odpylające gazy odlotowe; Środowisko ogólne – hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych | 1 to 135 mg/m3; dB |
| environmental | PN-EN 14181:2015-02; PN-Z-04030-7:1994; PN-ISO 10396:2001; PN-EN 12619:2013-05; PN-EN 14792:2017-04; PN-EN 14791:2017-04; PN-EN 15058:2017-04; PN-EN 14789:2017-04; PN-EN 14790:2017-04; PN-EN 1911:2011; ISO 15713:2006 | Air | 0.001 to 1000 g/m3; %; mg/m3; % obj. |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Poland
- "Energopomiar"Gliwice · ~272 kmPCAShares 5 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
- Eurofins SEPO Spółka z ograniczoną odpowiedzialnościąKnurów · ~279 kmPCAShares 5 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
- Laboratorium Badań i Pomiarów Środowiska EKOLAB Spółka Cywilna Janusz Michalak, Grażyna Felisiak, Anna WysockaŁódź · ~120 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03PN-Z-04030-7:1994Air
- CE2 Tech Consulting M. Dziewa i Wspólnicy Sp. j.Toruń · ~188 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03PN-Z-04030-7:1994Air
- SBB Laboratorium Badań i EkspertyzKatowice · ~267 kmPCAShares 4 accredited methods and materialsEN ISO 21877:2020-03ISO 10396:2001PN-Z-04030-7:1994
Accreditation data collected from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.