Device Conformity and Testing
suite 211, 94 jackson rd, 94 jackson rd, suite 211, 01434, Devens, MA, United States
Visit website- Accredited standards
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60601 series8
IEC 60601-1-4
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60601-2-2
IEC 60601-2-18
IEC 60601-2-64
IEC 60601-2-68
IEC 61010 series4
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-051
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
Other standards2
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08
IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6136.01
The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 6136.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEC 60950-1:2005/AMD2:2013; IEC 62368-1:2018; IEC 62368-1 Ed. 4 2023-05; IEC 60601-1:1988/AMD2:1995; IEC 60601-1:2005+A1:2012; IEC 60601-1:2005+A1:2012+A2:2020; ES60601-1:2005/(R)2012 and A1:2012 C1:2009/(R)2012 and A2:2010/(R)2012 (Consolidated Text); IEC 60601-1-4:1996/AMD1:1999; IEC 60601-1-6:2010+A1:2013+A2:2020; IEC 60601-1-6 Edition 3.1 2013-10; IEC 60601-1-6 Edition 3.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-8:2006+A1:2012+A2:2020; IEC 60601-1-8 Edition 2.1 2012-11; IEC 60601-1-8 Edition 2.2 2020-07 CONSOLIDATED VERSION; IEC 60601-1-11:2015+A1:2020; IEC 60601-1-11 Edition 2.0 2015-01; IEC 60601-1-11 Edition 2.1 2020-07 CONSOLIDATED VERSION; IEC 60601-2-2 Edition 6.0 2017-03; IEC 60601-2-2 Edition 6.1 2023-02; IEC 60601-2-18:2009-08 | Medical equipment, electrical safety and EMC | - |
| 2 | IEC 60601-2-64:2014-09; IEC 60601-2-68 Edition 1.0 2014-09; IEC 61010-1:2010+A1:2016; IEC 61010-1 Edition 3.1 2017-01; IEC 61010-2-010:2019; IEC 61010-2-051:2018; IEC 61010-2-101:2018; IEC 60601-1-6 Edition 3.2 2020-07; IEC 60601-1-8 Edition 2.2 2020-07; IEC 60601-1-11 Edition 2.1 2020-07; IEC 60601-2-2 Edition 6.0 2017-03 | Medical equipment, electrical safety and EMC | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
DEVICE CONFORMITY AND TESTING, LLC
Devens, MA
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets A2LA R256
- Specific Requirements - FDA ASCA Program. This accreditation demonstrates technical competence for a defined
scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 26th day of June 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6136.01
Valid to June 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
suite 211, 94 jackson rd, 94 jackson rd, suite 211, Devens, MA, 01434, US
42.53895, -71.60944
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.