Element Materials Technology Denver-Longmont
1736 Vista View Drive, 80504-5242, Longmont, CO, United States
Visit website- Accredited standards
- 31
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 31 standard numbers and the 30 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series15
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion+1 national
Limits written next to it
EN 61000-4-8 (excluding short duration mode)
Magnetic Field Immunity IEC 61000-4-8 (excluding short duration mode)
National versions in the same scope
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
KS C 9610-6-1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
KS C 9610-6-4national version with changes
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionExclusion+2 national
Limits written next to it
EN 55014-1(excluding disturbance power and click
National versions in the same scope
AS/NZS CISPR 14-1national version with changes
KS C 9814-1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
KS C 9814-2national version with changes
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+1 national
National versions in the same scope
KS C 9824probably the same standard; matched by number only
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion+4 national
Limits written next to it
EN 55032 (excluding Annex H)
National versions in the same scope
AS/NZS CISPR 32identical to it
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion+1 national
Limits written next to it
EN 55035 (excluding Annex
National versions in the same scope
KS C 9835national version with changes
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
ISO 7176-21Wheelchairs - Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargers
MIL-STD-461G
CFR 47 FCC, Part 15B; ANSI C63.4:2014; CFR 47 FCC, Part 18; MP-5:1986; CISPR 11; EN 55011; AS CISPR 11; KS C 9811; CISPR 32; EN 55032; AS/NZS CISPR 32; KS C 9832; VCCI-CISPR 32:2016; CISPR 14-1; EN 55014-1; AS/NZS CISPR 14-1; KS C 9814-1; CNS 15936 (2016); TCVN 7189; QCVN 118:2018/BTTTT; ICES-003; IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-12; EN 61000-3-12; IEC 61000-3-3; EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; ISO/IEC 17025:2017
IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEEE C62.41.1 (2002); IEEE C62.41.2 (2002); IEEE C62.45 (2002); IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-39; EN 61000-4-39; IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KN 61000-6-4; KS C 9610-6-4; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; EN 61326-1; CISPR 24; EN 55024; KS C 9824; CISPR 35; EN 55035; KS C 9835; CISPR 14-2; EN 55014-2; KS C 9814-2; ISO 7176-21; CISPR 25; ISO 11452-2; ISO 11452-2 (2019); ISO 11452-4; ISO 11452-4 (2020); ISO 11452-5; ISO 11452-5 (2002); ISO 11452-8; ISO 11452-8 (2015)
ANSI C63.4:2014; FCC MP-5 (February 1986)
MIL-STD-461E; MIL-STD-461F; MIL-STD-461G; MIL-STD-7043 D; MIL-STD-7043 E; MIL-STD-7043 F; MIL-HDBK-704-8; RTCA DO-160G
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active214.43
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 214.43
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47 FCC, Part 15B; ANSI C63.4:2014; CFR 47 FCC, Part 18; MP-5:1986; CISPR 11; EN 55011; AS CISPR 11; KS C 9811; CISPR 32; EN 55032; AS/NZS CISPR 32; KS C 9832; VCCI-CISPR 32:2016; CISPR 14-1; EN 55014-1; AS/NZS CISPR 14-1; KS C 9814-1; CNS 15936 (2016); TCVN 7189; QCVN 118:2018/BTTTT; ICES-003; IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-12; EN 61000-3-12; IEC 61000-3-3; EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; ISO/IEC 17025:2017 | - | - |
| 2 | IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEEE C62.41.1 (2002); IEEE C62.41.2 (2002); IEEE C62.45 (2002); IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-39; EN 61000-4-39; IEC 61000-4-11; EN 61000-4-11; KS C 9610-4-11; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KN 61000-6-4; KS C 9610-6-4; IEC 60601-1-2; EN 60601-1-2; KS C IEC 60601-1-2; EN 61326-1; CISPR 24; EN 55024; KS C 9824; CISPR 35; EN 55035; KS C 9835; CISPR 14-2; EN 55014-2; KS C 9814-2; ISO 7176-21; CISPR 25; ISO 11452-2; ISO 11452-2 (2019); ISO 11452-4; ISO 11452-4 (2020); ISO 11452-5; ISO 11452-5 (2002); ISO 11452-8; ISO 11452-8 (2015) | - | See scope document |
| 3 | MIL-STD-461E; MIL-STD-461F; MIL-STD-461G; MIL-STD-7043 D; MIL-STD-7043 E; MIL-STD-7043 F; MIL-HDBK-704-8; RTCA DO-160G | - | See scope document |
| 4 | ANSI C63.4:2014; FCC MP-5 (February 1986) | - | to 40000 MHz |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
ELEMENT MATERIALS TECHNOLOGY DENVER-
LONGMONT
Longmont, CO
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 28th day of March 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 214.43
Valid to March 31, 2026
Revised February 16, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Applied Technical ServicesChandler, AZ · ~977 kmA2LAShares 1 accredited test methodMIL-STD-461G
- International Certification ServicesGlencoe, MN · ~1,032 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Element Materials Technology Dallas – Plano WestPlano, TX · ~1,093 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Element Materials Technology Minneapolis - Brooklyn ParkBrooklyn Park, MN · ~1,106 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Intertek Testing Services NAFridley, MN · ~1,111 kmA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.