Vermont Thread Gage
564 Reasonover Drive, PO Box 245, 42135, Franklin, KY, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3821.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3821.01) 06/06/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Tapered Thread Plug –
Major Diameter
Simple Pitch Diameter
Taper
Lead
Flank Angle
Up to 12 in
Up to 12 in
Up to 12 in
Up to 12 in
180°
(97 + 7L) µin
(76 + 6L) µin
(110 + 9L) µin
130 µin
4.3´
6´
Mikrokator, gage
blocks, taper blocks
Mikrokator, gage
blocks, 3-wire method
PD measurements
Zeiss Contourecord
Zeiss Contourecord
Optical comparator
Tapered Thread Ring –
Pitch Diameter
Standoff
Minor Diameter
Up to 12 in
Up to 12 in
Up to 12 in
(210 + 17L) µin
(0.0034 + 0.000 28L) in
(140 + 9L) µin
Master plugs
Tapered Plain Plug –
Major Diameter
Taper
Up to 12 in
Up to 12 in
(110 + 6L) µin
(150 + 9L) µin
Mikrokator, gage
blocks, taper blocks
OD measurements
Tapered Plain Ring –
Minor Diameter
Taper
Up to 12 in
Up to 12 in
(140 + 7L) µin
(330 + 1L) µin
Master plug
Zeiss Contourecord | to 12 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3821.01) 06/06/2025 Page 3 of 3
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Hex, Square, and
Rectangular Plugs –
Across Flats
Across Corners
Up to 0.0999 in
(0.1000 to 3) in
Up to 0.0999 in
(0.1000 to 3) in
51 µin
(37 + 5L) µin
98 µin
(50 + 3L) µin
Mikrokator, gage
blocks
Length – Gage and Step
Height
Up to 4 in
(120 + 8L) µin
Gage blocks, indicator
w/ stand
________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’ s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | to 0.0999 in |
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Tektronix, Inc. - CincinnatiCincinnati, OH · ~99 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- The Modal Shop Inc, An Amphenol CompanyCincinnati, OH · ~99 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationWest Chester, OH · ~126 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DaytonSpringboro, OH · ~155 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western Environmental a Division of Controlled Environment Systems (CES)Springboro, OH · ~155 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.