EUROFINS ELECTRICAL AND ELECTRONICS FRANCE - VILLEJUST
EUROFINS ELECTRICAL AND ELECTRONICS FRANCE - VILLEJUST, France
- Accredited standards
- 8
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-52
CISPR 16-2-1; EN 55016-2-1; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; IEC/EN/NF 55032 - CISPR 32; IEC/EN/NF 55011 - CISPR 11; IEC/EN/NF 55014-1 – CISPR 14-1; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-3; IEC/EN/NF 61000-6-4; EN 50121-3-2; EN 50121-4; CISPR 16-2-1; IEC/EN/NF 60601-1-2; IEC/EN/NF 55032 - CISPR 32; IEC/EN/NF 55014 - CISPR 14-1; IEC/EN/NF 55014 - CISPR 14-1; IEC/EN/NF 60601-1-2
CISPR16-2-3 / 55016-2-3; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; IEC/EN/NF 55032 - CISPR 32; IEC/EN/NF 55011 - CISPR 11; IEC/EN/NF 55014-1 – CISPR 14-1; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-3; IEC/EN/NF 61000-6-4; EN 50121-3-2; EN 50121-4
IEC/EN/NF 61000-4-3; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-1; IEC/EN/NF 61000-6-2; IEC/EN/NF 55014-2 / CISPR 14-2; IEC/EN/NF 55035 / CISPR 35; EN 50121-3-2; EN 50121-4
IEC/EN/NF 61000-4-2; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-1; IEC/EN/NF 61000-6-2; IEC/EN/NF 55014-2 / CISPR 14-2; IEC/EN/NF 55035 / CISPR 35; EN 50121-3-2; EN 50121-4; IEC/EN/NF 61000-4-4
IEC/EN/NF 61000-4-5; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-1; IEC/EN/NF 61000-6-2; IEC/EN/NF 55014-2 / CISPR 14-2; IEC/EN/NF 55035 / CISPR 35; EN 50121-3-2; EN 50121-4; IEC/EN/NF 61000-4-6
IEC/EN/NF 61000-4-8; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-1; IEC/EN/NF 61000-6-2; IEC/EN/NF 55014-2 / CISPR 14-2; IEC/EN/NF 55035 / CISPR 35; EN 50121-4; IEC/EN/NF 61000-4-11
IEC/EN/NF 61000-3-2; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-3; IEC/EN/NF 61000-6-4; IEC/EN/NF 61000-3-3; IEC/EN/NF 60601-1-2; IEC/EN/NF 61326-1; IEC/EN/NF 61326-2-1; IEC/EN/NF 61326-2-3; IEC/EN/NF 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; EN 301 489-52; IEC/EN/NF 61000-6-3; IEC/EN/NF 61000-6-4
Read from the scope as published by COFRAC. Register refreshed 2026-11-20.
Scope as published by COFRAC
9 lines
ISO/IEC 17025
Active1-7282
Labs with overlapping accredited scope in France
- ACM PHARMABELLEGARDECOFRACShares 1 accredited materialOther
- ADETESTSSAINT-CHAMOND (42207)COFRACShares 1 accredited materialOther
- ARENIUSCHATEAUBOURGCOFRACShares 1 accredited materialOther
- EMITECHMONTIGNY-LE-BRETONNEUXCOFRACShares 1 accredited materialOther
- ENVIRONNE'TECHBOURGOIN-JALLIEUCOFRACShares 1 accredited materialOther
Accreditation data refreshed from the COFRAC register on .