SIMCO Electronics - Dallas
783 N. Grove Rd. Ste. 106, 75081, Richardson, TX, United States
Visit website- Scope lines
- 39
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 39 scope lines.
A2LA certificate 1395.03 · 18 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 2 of 17
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Cylindrical Plug
Gages & Master Discs
Up to 1 in
(1 to 12) in
10 µin
(4.8 + 5L) µin
Pratt & Whitney
LabMaster™ Universal &
gage blocks
Cylindrical Ring
Gages
(0.040 to 1.0) in
(>1.0 to 14) in
10 µin
(8.8 + 3.3L) µin
Pratt & Whitney
LabMaster™ Universal
&
gage blocks
Thread Plugs –
UN (60° threads)
UN
Pitch Diameter:
Up to 12 in,
Pitch: (4 to 80) TPI
Pitch Diameter:
(1 to 300) mm,
Pitch: (0.3 to 4) mm
Major Diameter:
Up to 1 in
(1 to 12) in
(70 + 5L) µin
(1.7 + 0.13L) µm
10 µin
(4.8 + 5L) µin
Pratt & Whitney
LabMaster™ Universal,
gage blocks & thread
wires
Pratt & Whitney
LabMaster™ Universal
& gage blocks
Wafer Film Thickness
Standards
(3.0 to 1500) nm
0.65 nm
Woolam VASE system
w/ NIST SRMs:
NIST 2534
NIST 2531
NIST 2532
Precision Step Height
Standards
(10 to 100) nm
(>100 to 2500) nm
2.5 %
0.6 %
Veeco Dektak 3
comparator, Veeco 138 -
367, -369, -371 step
height standards | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 3 of 17
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage3 – Generate
Fixed Points
Up to 220 mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
(1 to 75) kV
1 V
1.018 V
10 V
8.1 µV/V + 0.4 µV
4.6 µV/V + 0.7 µV
3.5 µV/V + 2.5 µV
3.5 µV/V + 4 µV
4.4 µV/V + 40 µV
5.2 µV/V + 400 µV
0.16 %
2 μV/V
4 μV/V
1 μV/V
Fluke Calibrator 5700A
EP
ROSS probe
VD90-16.5Y-AK-K
Fluke Zener standard
732A
DC Voltage3 – Measure
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1050) V
(1 to 90) kV
6.4 µV/V + 0.1 µV
4.1 µV/V + 0.4 µV
4.4 µV/V + 4.0 µV
5.9 µV/V + 40 µV
5.9 µV/V + 0.50 mV
0.16 %
Fluke DMM 8508A
ROSS probe
VD90-16.5Y-AK-K
DC Current3 –
Generate
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(1 to 10) A
(10 to 100) A
37 µA/A + 6 nA
32 µA/A + 7 nA
35 µA/A + 40 nA
41 µA/A + 0.7 µA
64 µA/A + 12 µA
0.034 % + 0.48 mA
0.015 %
0.052 %
Fluke calibrator 5700A
EP
Fluke amplifier 5725A
Guildline 9211A shunt,
HP 6031A, Fluke DMM
8508A
DC Current – Clamp
Meters
3
(10 to 16.5) A
(16.5 to 150) A
(150 to 1000) A
0.40 % + 0.06 A
0.40 % + 0.06 A
0.40 % + 0.06 A
Fluke 5500A/coil &
5520A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 4 of 17
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Current3 –
Measure
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(1 to 10) A
(10 to 20) A
(20 to 100) A
(100 to 300) A
13 µA/A + 0.4 nA
13 µA/A + 4 nA
15 µA/A + 40 nA
50 µA/A + 0.8 µA
0.019 % + 16 µA
0.042 % + 0.40 mA
0.015 %
0.054 %
0.052 %
0.11 %
Fluke DMM 8508A
Guildline 9211A shunt,
Fluke DMM 8508A
Resistance3 – Generate
Fixed Points
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
(100, 190) Ω
1 kΩ
1.9 kΩ
(10, 19) kΩ
100 kΩ
190 kΩ
36 μΩ/Ω + 0.78 mΩ
27 μΩ/Ω + 1.2 mΩ
25 μΩ/Ω + 1.1 mΩ
25 μΩ/Ω + 1.6 mΩ
25 μΩ/Ω + 1.6 mΩ
26 μΩ/Ω + 16 mΩ
26 μΩ/Ω + 16 mΩ
26 μΩ/Ω + 0.16 Ω
26 μΩ/Ω + 0.16 Ω
28 μΩ/Ω + 1.6 Ω
28 μΩ/Ω + 1.6 Ω
50 μΩ/Ω + 24 Ω
0.011 % + 39 Ω
0.021 % + 2 kΩ
0.040 % + 2.4 kΩ
0.24 % + 78 kΩ
1.2 % + 0.39 MΩ
52 µΩ
84 µΩ/Ω
84 µΩ/Ω
24 µΩ/Ω
25 µΩ/Ω
11 µΩ/Ω
8.6 µΩ/Ω
8.0 µΩ/Ω
8.0 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
Fluke 5522A
Fluke calibrator 5700A
EP | to 20 A |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 5 of 17
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Resistance3 – Generate
(cont)
Fixed Points
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
16 µΩ/Ω
17 µΩ/Ω
34 µΩ/Ω
42 µΩ/Ω
0.011 %
Fluke calibrator 5700A
EP
Resistance3 – Measure
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 100) GΩ
20 µΩ/Ω + 4 µΩ
11 µΩ/Ω + 14 µΩ
8.6 µΩ/Ω + 50 µΩ
8.6 µΩ/Ω + 500 µΩ
8.6 µΩ/Ω + 5 mΩ
8.9 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1.0 Ω
24 µΩ/Ω + 0.10 kΩ
80 µΩ/Ω + 1 kΩ
0.022 % + 100 kΩ
0.74 %
Fluke DMM 8508A
Keithley 6517B
Electrical Simulation
of Thermocouples
3 –
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.41 °C
0.18 °C
0.17 °C
0.18 °C
0.21 °C
0.24 °C
0.18 °C
0.17 °C
0.18 °C
0.22 °C
0.28 °C
0.19 °C
0.18 °C
0.24 °C
0.33 °C
0.50 °C
0.22 °C
0.18 °C
0.17 °C
Fluke calibrator 5522A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 6 of 17
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3–
Generate
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.19 % + 4 µV
0.12 % + 4 µV
0.10 % + 4 µV
0.15 % + 4 µV
0.20 % + 5 µV
0.36 % + 10 µV
0.52 % + 20 µV
0.65 % + 20 µV
0.024 % + 4 µV
0.012 % + 4 µV
0.011 % + 4 µV
0.025 % + 4 µV
0.053 % + 5 µV
0.097 % + 10 µV
0.13 % + 20 µV
0.27 % + 20 µV
0.022 % + 12 µV
95 µV/V + 7 µV
79 µV/V + 7 µV
0.019 % + 7 µV
0.043 % + 17 µV
0.076 % + 20 µV
0.12 % + 25 µV
0.26 % + 45 µV
0.024 % + 40 µV
88 µV/V + 15 µV
47 µV/V + 8 µV
78 µV/V + 10 µV
0.011 % + 30 µV
0.036 % + 80 µV
0.091 % + 0.20 mV
0.15 % + 0.30 mV
0.022 % + 0.40 mV
89 µV/V + 0.15 mV
47 µV/V + 50 µV
77 µV/V + 0.10 mV
0.010 % + 0.20 mV
0.028 % + 0.60 mV
0.091 % + 2 mV
0.14 % + 3.2 mV
Fluke calibrator 5700A
EP
Subject to a 2.2 x 10
7 V-
Hz output | to 2.2 V |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 7 of 17
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Voltage3 –
Generate (cont)
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(750 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
(30 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
0.022 % + 4.0 mV
88 µV/V + 1.5 mV
53 µV/V + 0.60 mV
87 µV/V + 1.0 mV
0.014 % + 2.5 mV
0.080 % + 16 mV
0.42 % + 40 mV
0.70 % + 80 mV
0.026 % + 16 mV
70 µV/V + 3.5 mV
0.037 % + 11 mV
0.14 % + 45 mV
87 µV/V + 4 mV
0.013 % + 6 mV
0.037 % + 11 mV
Fluke calibrator 700A
EP w/ Fluke amplifier
5725A (max. output =
250 V for [15 to 50] Hz)
Fluke calibrator 700A EP
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
AC Voltage3 –
Measure
(1 to 65) kV
(50 to 60) Hz
0.60 %
Ross VD90-16.5Y-AK-K
& Fluke 8508A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 8 of 17
Parameter/Range
Frequency CMC2, 5 (±) Comments
AC Current3 –
Generate
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.024 % + 16 nA
0.015 % + 10 nA
0.012 % + 8 nA
0.030 % + 12 nA
0.094 % + 65 nA
0.024 % + 40 nA
0.015 % + 35 nA
0.012 % + 35 nA
0.019 % + 110 nA
0.090 % + 0.65 µA
0.026 % + 0.40 µA
0.015 % + 0.35 µA
0.012 % + 0.35 µA
0.019 % + 0.55 µA
0.090 % + 5 µA
0.026 % + 4 µA
0.015 % + 3.5 µA
0.012 % + 2.5 µA
0.019 % + 3.5 µA
0.092 % + 10 µA
0.025 % + 35 µA
0.040 % + 80 µA
0.60 % + 0.16 mA
0.050 % + 0.17 mA
0.090 % + 0.38 mA
0.33 % + 0.75 mA
Fluke calibrator 5700 A
EP w/ Fluke 5725A | to 11 A |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 9 of 17
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
AC Current – Clamp
Meters3–
(0 to 500) A
(500 to 1000) A
(45 to 440) Hz
(45 to 440) Hz
0.37 % + 0.1 A
0.39 % + 0.2 A
Fluke 5522A w/5500
coil
AC Current3 –
Measure
Up to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.037 % + 20 nA
0.031 % + 200 nA
0.032 % + 2 µA
0.030 % + 20 µA
0.062 % + 200 µA
0.075 % + 200 µA
0.082 % + 2 mA
0.25 % + 2 mA
Fluke DMM 8508A
Oscilloscope3 –
DC Signal
Rise/Fall Times
± 1 mV to ± 200 Vdc
(into 50 Ω)
± 1 mV to ± 50 Vdc
(into 1 MΩ)
40 μV to <1 mV
pk-pk
1 mV to 200 Vpk-pk
50 kHz Reference
Amplitude
0.1 Hz to 300 MHz
(>300 to 550) MHz
(>0.55 to 2.5) GHz
(>2.5 to 3.0) GHz
(350 to 550) ps
10 Hz to 2 MHz
0.061 % + 25 μV
0.061 % + 25 μV
0.83 % + 10 μV
0.16 % + 10 μV
1.2 %
2.2 %
2.5 %
2.8 %
2.8 %
33 ps
Fluke 9500B scope
calibrator w/
9530 heads | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 10 of 17
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Oscilloscope3 – (cont)
Rise/Fall Times
Timing Marker
Functions
Pulse Width
(125 to 175) ps
10 Hz to 2 MHz
9.0091 ns to <83 μs
≥83 μs to 55 s
(1 to 100) ns
14 ps
0.2 μs/s
2.3 μs/s
4.1 % + 200 ps
Fluke 9500B scope
calibrator w/ 9530 heads
Capacitance3 – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
(1, 10) pF
(100, 1000) pF
(0.01, 0.1, 1) µF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 600 Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
1 kHz
0.61 % + 7.8 pF
0.44 % + 7.8 pF
0.42 % + 7.8 pF
0.24 % + 7.8 pF
0.23 % + 7.8 pF
0.23 % + 7.8 pF
0.23 % + 0.23 nF
0.23 % + 0.8 nF
0.23 % + 2.3 nF
0.23 % + 7.8 nF
0.33 % + 23 nF
0.37 % + 78 nF
0.37 % + 0.23 µF
0.37 % + 0.8 µF
0.37 % + 2.3 µF
0.37 % + 8 µF
0.59 % + 23 µF
0.86 % + 78 µF
0.13 %
Fluke calibrator 5522A
Agilent 16380A/16380C
standard air capacitor
set, BNC 4 terminal pair | to 55 s |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 11 of 17
Parameter/Range
Frequency CMC2, 4, 5 (±) Comments
Capacitance3 –
Generate (cont)
Fixed Points:
1 pF
10 pF
100 pF
1000 pF
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
0.12 %
0.12 %
0.13 %
0.14 %
0.15 %
0.28 %
0.39 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.12 %
0.13 %
0.13 %
0.12 %
0.12 %
0.12 %
0.13 %
0.14 %
0.23 %
0.31 %
Agilent 16380A/16380C
standard air capacitor set,
BNC 4 terminal pair
Capacitance3 –
Measure
1 pF to 1 µF
1 pF to 100 mF
1 kHz
20 Hz to 1 MHz
61 µF/F
0.064 %
Andeen Hagerling 2500A
capacitance bridge
HP 4284A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 12 of 17
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
RF Power3 – Generate
(+13 to -5) dBm
(-6 to -45) dBm
(-46 to -85) dBm
(+20 to -100) dBm
200 Hz to 80 MHz
2.5 MHz to 26.5 GHz
0.09 dB
0.13 dB
0.20 dB
0.55 dB
HP 3335A generator
HP 8340B synthesizer
w/ HP 8902 audio
analyzer; HP 11722A,
HP 11792A sensors, HP
11793A converter
RF Power3 – Measure
(-20 to + 30) dBm
100 kHz to 2.6 GHz
50 MHz to 26.5 GHz
0.056 dB + 1 digit
0.13 dB + 1 digit
HP 8902A measuring
receiver w/ HP 11792A
power sensor
Tuned RF Power –
Measure (Relative)
(+10 to 0) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(0.15 to 1300) MHz
0.11 dB
0.11 dB
0.12 dB
0.14 dB
0.15 dB
0.16 dB
0.18 dB
0.21 dB
0.23 dB
0.25 dB
0.27 dB
0.29 dB
0.52 dB
HP 8902A measuring
receiver w/ HP 11722A
power sensor | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 13 of 17
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Tuned RF Power – Measure
(Relative)
(cont)
(+10 to 0) dB
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(-110 to -120) dB
(1.3 to 26.5) GHz
0.11 dB
0.11 dB
0.11 dB
0.13 dB
0.15 dB
0.16 dB
0.18 dB
0.21 dB
0.23 dB
0.25 dB
0.27 dB
0.29 dB
0.52 dB
HP 8902A measuring
receiver w/ HP 11793A
converter, HP 11792A
power sensor
Amplitude Modulation3 –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depth: To 99 %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: To 99 %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: To 99 %
150 kHz to 10 MHz
(10 to 1300) MHz
(1.3 to 26.5) GHz
2.1 % + 1 digit
3.0 % + 1 digit
1.1 % + 1 digit
3.0 % + 1 digit
1.6 % + 1 digit
3.0 % + 1 digit
HP 8902A measuring
receiver w/ HP
11793A converter, HP
11792A power sensor | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 14 of 17
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Frequency Modulation3 –
Measure
Rate: 20 Hz to 10 kHz
Dev.: ≤40 kHz peak
Rate: 50 Hz to 100 kHz
Dev.: ≤400 kHz peak
Rate: 20 Hz to 200 kHz
Dev.: ≤400 kHz peak
250 kHz to 10 MHz
(10 to 1300) MHz
(10 to 1300) MHz
2.0 % + 1 digit
1.1 % + 1 digit
5.0 % + 1 digit
HP 8902A measuring
receiver
Phase Modulation –
Measure
Rate: 200 Hz to 10 kHz
Rate: 20 Hz to 200 kHz
150 kHz to 10 MHz
10 MHz to 26.5 GHz
4 % + 0.015 rad
5 % + 0.019 rad
HP 8902A measuring
receiver w/
HP 11792A power
sensor
Audio Distortion –
Measure
(-80 to 0) dB
(-65 to 0) dB
Harmonic Distortion –
Measure & Measuring
Equipment
(-95 to 0) dB
(20 Hz to 20 kHz
(20 to 100) kHz
>100 kHz to 13.2 GHz
1.7 dB
2.4 dB
2.7 dB
HP 8903B audio
analyzer
HP 8563E spectrum
analyzer
In Line RF Power Meters –
Measuring Equipment
(1 to 80) W
(0.1 to 500) MHz
(0.5 to 1.0) GHz
1.7 %
1.9 %
RF Attenuator, Agilent
8478B w/8482,
Agilent N478 w/8482,
AR amplifier | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 15 of 17
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Scales & Balances3
(1 to 500) mg
(0.5 to 5) g
(5 to 20) g
(20 to 500) g
(0.5 to 5) kg
(10 to 500) lb
0.024 mg + 0.6R
0.040 mg + 0.6R
0.078 mg + 0.6R
2.5 µg/g + 0.6R
5.4 µg/g + 0.6R
0.010 % + 0.6R
Class 1 weights
Class 2 weights
Class F weights
Pressure3 –
Measuring Equipment
Nitrogen Gas
Hydraulic
(0 to 90) psia
(>90 to 300) psia
(300 to 1000) psia
(-14.5 to 300) psig
(300 to 1000) psig
(1000 to 2000) psig
(2000 to 10 000) psig
0.0021 % + 0.009 psia + 0.58R
0.0054 % + 0.015 psia + 0.6R
0.01 % + 0.01 psia + 0.6R
0.0054 % + 0.015 psi + 0.6R
0.01 % + 0.01 psi + 0.6R
0.011 % + 2.1 psi + 0.6R
0.10 % + 0.45 psi + 0.6R
Additel ADT780
pressure calibrator
Crystal reference
pressure gauge
Torque – Measuring
Equipment3
(1 to 10) ozf∙in
(10 to 100) ozf∙in
(5 to 50) lbf∙in
50 lbf∙in to 250 lbf∙ft
1.4 %
1.7 %
0.64 % + 0.58R
1.7 %
Digital torque load
cells
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature3 –
Measuring Equipment
-80 °C ± 10 °C
0 °C
(50 to 420) °C
(420 to 660) °C
0.023 °C
0.023 °C
0.12 °C
0.17 °C
Dry ice/alcohol
slurry, PRT
Wahl IPR4-1 ice
point reference,
PRT
Fluke 9144 dry well,
PRT calibrator 3125 | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 16 of 17
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature3 –
Measure
(Dry blocks, Ovens,
Chambers, Furnaces,
Freezers)
(-196 to 400) °C
(400 to 660) °C
0.018 °C
0.020 °C
Hart Scientific 5626
PRT w/Fluke 8508A
DMM
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Frequency Reference
10 MHz Reference
Signal
1.8 × 10-12 Hz/Hz
Fluke 910 GPS
receiver
Frequency3 –
Measuring Equipment
1 µHz to 26.5 GHz
1.8 x 10-12 Hz/Hz + 0.58R
GPS receiver w/
synthesized generator
Frequency3 – Measure
DC to 225 MHz
225 MHz to 26.5 GHz
1.5 × 10-9 Hz/Hz + 5 µHz
1.8 × 10
-12 Hz/Hz + 1.3 Hz
GPS receiver w/
53132 counter
5343A counter
Stopwatches &
Timers3
(0 to 19.99) s/day
0.12 s/day
Timometer
__________________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.03) 12/01/2025 Page 17 of 17
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is defined as the length of the unit under test in inches, D is the diameter of
the unit under test in inches, R is the resolution of the device under test and % is percentage of reading,
unless otherwise indicated.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 18 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
A2LA certificate 1395.26 · 21 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 2 of 20
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Thread Wires (Constant) –
60° Thread Wire Size –
Wire Set
29° Thread Wire Size
(4 to 80) TPI
Constant
(0.1 to 10) mm
Constant
(1 to 20) TPI
5.5 µin
(17 µin)
0.14 µm
(0.42 µm)
6.5 µin
Pratt & Whitney
LabMaster™, master
thread wires
English set
Metric set
Pratt & Whitney
LabMaster™, gage
blocks
Threaded Plug Gages –
UN (60° Threads)
UN
Pitch Diameter:
Up to 12 in
Pitch: (4 to 80) TPI
Pitch Diameter:
(1 to 300) mm
Pitch: (0.3 to 4) mm
Major Diameter:
Up to 1 in
(1 to 12) in
(67 + 5L) µin
(1.7 + 0.13L) µm
(3.8 + 5L) µin
(3.8 + 5L) µin
Gage blocks w/ thread
wire & Pratt &
Whitney LabMaster™ | 4 to 80 TPI |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 3 of 20
II. Electrical – DC/Low Frequency
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
Up to 220 µA
>220 µA to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
(>0.22 to 2.2) A
(>2.2 to 11) A
(>11 to 20) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 100 Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.024 % + 0.016 µA
0.016 % + 0.010 µA
0.012 % + 0.008 µA
0.03 % + 0.012 µA
0.094 % + 0.065 µA
0.024 % + 0.04 µA
0.015 % + 0.035 µA
0.012 % + 0.035 µA
0.020 % + 0.11 µA
0.091 % + 0.65 µA
0.026 % + 0.4 µA
0.016 % + 0.35 µA
0.012 % + 0.35 µA
0.019 % + 0.55 µA
0.091 % + 5 µA
0.027 % + 4 µA
0.016 % + 3.5 µA
0.013 % + 2.5 µA
0.020 % + 3.5 µA
0.092 % + 10 µA
0.025 % + 0.035 mA
0.025 % + 0.035 mA
0.041 % + 0.080 mA
0.61 % + 0.16 mA
0.042 % + 0.17 mA
0.086 % + 0.38 mA
0.33 % + 0.75 mA
0.13 % + 5 mA
0.16 % + 5 mA
3 % + 5 mA
Fluke 5730A
Fluke 5725A
Fluke 5520A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 4 of 20
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Measure
Up to 200 µA
>200 µA to 2 mA
(>2 to 20) mA
(>20 to 200) mA
>200 mA to 2 A
(>2 to 10) A
(>10 to 20) A
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
17 µA/A + 30 pA
20 µA/A + 30 pA
21 µA/A + 0.3 nA
17 µA/A + 0.3 nA
20 µA/A + 0.3 nA
24 µA/A + 0.3 nA
43 µA/A + 30 nA
35 µA/A + 30 nA
54 µA/A + 30 nA
48 µA/A + 300 nA
34 µA/A + 300 nA
62 µA/A + 300 nA
58 µA/A + 3 µA
38 µA/A + 3 µA
100 µA/A + 3 µA
100 µA/A + 30 µA
65 µA/A + 30 µA
190 µA/A + 30 µA
150 µA/A + 300 µA
120 µA/A + 300 µA
620 µA/A + 400 µA
Fluke A40 shunts,
Fluke 5790B, metal
film resistors
AC Voltage – Generate
Up to 2.2 mV
(>2.2 to 22) mV
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(300 to 500) kHz
(>0.5 to 1) MHz
0.039 % + 4 µV
0.081 % + 4 µV
0.096 % + 4 µV
0.032 % + 4 µV
0.057 % + 5 µV
0.13 % + 10 µV
0.21 % + 20 µV
0.36 % + 20 µV
0.025 % + 4 µV
0.013 % + 4 µV
0.013 % + 4 µV
0.019 % + 4 µV
0.05 % + 5 µV
0.09 % + 10 µV
0.12 % + 20 µV
0.29 % + 20 µV
Fluke 5730A, opt 03 | to 20 A |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 5 of 20
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont)
(>22 to 220) mV
(>0.22 to 2.2) V
(>2.2 to 22) V
(>22 to 220) V
(>220 to 1100) V
(220 to 750) V
(750 to 1100) V
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
(>0.5 to 1) MHz
(15 to 50) Hz
<50 Hz to 1 kHz
(30 to 50) kHz
(50 to 100) kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
0.023 % + 12 µV
0.009 % + 7 µV
0.008 % + 7 µV
0.019 % + 7 µV
0.043 % + 17 µV
0.077 % + 20 µV
0.12 % + 25 µV
0.26 % + 45 µV
0.023 % + 40 µV
0.008 % + 15 µV
0.0044 % + 8 µV
0.0072 % + 10 µV
0.011 % + 30 µV
0.035 % + 80 µV
0.091 % + 200 µV
0.16 % + 300 µV
0.022 % + 400 µV
0.0086 % + 150 µV
0.0045 % + 50 µV
0.007 % + 100 µV
0.010 % + 200 µV
0.030 % + 600 µV
0.091 % + 2000 µV
0.16 % + 3200 µV
0.023 % + 4 mV
0.0089 % + 1.5 mV
0.0054 % + 0.6 mV
0.0078 % + 1.0 mV
0.014 % + 2.5 mV
0.081 % + 16 mV
0.42 % + 40 mV
0.70 % + 80 mV
0.026 % + 16 mV
67 µV/V + 3.5 mV
0.037 % + 11 mV
0.13 % + 45 mV
87 µV/V + 4 mV
0.013 % + 6 mV
0.037 % + 11 mV
Fluke 5730A
Fluke 5730A opt 03
5730A opt 03, 5725A | ||
| 6 | - | Measuring EquipmentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 6 of 20
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure,
Measuring Equipment
Up to 2.2 mV
(>2.2 to 7) mV
(>7 to 22) mV
(>22 to 70) mV
(>70 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
202 µV/V + 1.0 µV
203 µV/V + 1.0 µV
203 µV/V + 1.0 µV
203 µV/V + 1.6 µV
233 µV/V + 2.0 µV
310 µV/V + 3.2 µV
376 µV/V + 6.3 µV
1305 µV/V + 6.3 µV
81 µV/V + 1.0 µV
81 µV/V + 1.0 µV
81 µV/V + 1.0 µV
80 µV/V + 1.6 µV
90 µV/V + 2.0 µV
210 µV/V + 3.2 µV
263 µV/V + 6.3 µV
551 µV/V + 6.3 µV
71 µV/V + 1.0 µV
60 µV/V + 1.0 µV
40 µV/V + 1.0 µV
50 µV/V + 1.6 µV
85 µV/V + 2.0 µV
200 µV/V + 3.2 µV
250 µV/V + 6.3 µV
400 µV/V + 6.3 µV
100 µV/V + 1.2 µV
100 µV/V + 1.2 µV
67 µV/V + 1.2 µV
53 µV/V + 1.2 µV
72 µV/V + 1.6 µV
140 µV/V + 2.0 µV
270 µV/V + 3.2 µV
350 µV/V + 6.3 µV
410 µV/V + 6.3 µV
37 µV/V + 1.2 µV
37 µV/V + 1.2 µV
25 µV/V + 1.2 µV
19 µV/V + 1.2 µV
41 µV/V + 1.7 µV
76 µV/V + 2.0 µV
120 µV/V + 3.2 µV
130 µV/V + 6.3 µV
230 µV/V + 6.3 µV
Fluke 5790B, Fluke
5730A opt 03 | to 2.2 mV |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 7 of 20
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Measure
(cont)
(>220 to 700) mV
>700 mV to 2.2 V
(>2.2 to 7) V
(>7 to 22) V
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
33 µV/V + 1.2 µV
33 µV/V + 1.2 µV
35 µV/V + 1.2 µV
12 µV/V + 1.2 µV
22 µV/V + 1.6 µV
23 µV/V + 2.0 µV
95 µV/V + 3.2 µV
76 µV/V + 6.3 µV
150 µV/V + 6.3 µV
30 µV/V
30 µV/V
23 µV/V
9 µV/V
14 µV/V
12 µV/V
90 µV/V
90 µV/V
240 µV/V
29 µV/V
29 µV/V
22 µV/V
9 µV/V
21 µV/V
11 µV/V
75 µV/V
75 µV/V
240 µV/V
28 µV/V
28 µV/V
30 µV/V
11 µV/V
11 µV/V
16 µV/V
85 µV/V
90 µV/V
240 µV/V
Fluke 5790B | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 8 of 20
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Measure
(cont)
(>22 to 70) V
(>70 to 220) V
(>200 to 700) V
(>700 to 1000) V
(9.5 to 10) Hz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
27 µV/V
27 µV/V
22 µV/V
14 µV/V
31 µV/V
16 µV/V
71 µV/V
88 µV/V
110 µV/V
40 µV/V
23 µV/V
18 µV/V
16 µV/V
21 µV/V
29 µV/V
24 µV/V
22 µV/V
17 µV/V
18 µV/V
37 µV/V
55 µV/V
24 µV/V
22 µV/V
25 µV/V
42 µV/V
54 µV/V
Fluke 5790B
AC Flatness – Measure
Up to 2.2 mV
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
0.088 %
0.046 %
0.046 %
0.050 %
0.063 % + 0.75 µV
0.063 % + 0.78 µV
0.063 % + 0.78 µV
0.14 % + 0.78 µV
0.25 % + 0.78 µV
0.56 % + 1.6 µV
0.82 % + 1.6 µV
5790B wideband | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 9 of 20
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Flatness – Measure
(cont)
(2.2 to 7) mV
(7 to 22) mV
(22 to 70) mV
(70 to 220) mV
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
0.082 %
0.047 %
0.041 %
0.048 %
0.057 % + 0.78 µV
0.058 % + 0.78 µV
0.058 % + 0.78 µV
0.087 % + 0.78 µV
0.15 % + 0.78 µV
0.32 % + 0.78 µV
0.45 % + 0.78 µV
0.081 %
0.040 %
0.040 %
0.042 %
0.056 %
0.058 %
0.058 %
0.087 %
0.15 %
0.32 %
0.52 %
0.080 %
0.10 %
0.040 %
0.040 %
0.042 %
0.043 %
0.043 %
0.085 %
0.13 %
0.30 %
0.51 %
0.08 %
0.033 %
0.033 %
0.034 %
0.034 %
0.043 %
0.043 %
0.084 %
0.13 %
0.30 %
0.51 %
5790B wideband | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 10 of 20
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Flatness – Measure
(cont)
(220 to 700) mV
700 mV to 2.2 V
(2.2 to 7) V
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 30) Hz
(30 to 120) Hz
120 Hz to 1.2 kHz
(1.2 to 120) kHz
(120 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
0.079 %
0.025 %
0.025 %
0.025 %
0.028 %
0.043 %
0.043 %
0.083 %
0.13 %
0.30 %
0.51 %
0.079 %
0.025 %
0.025 %
0.025 %
0.027 %
0.043 %
0.043 %
0.083 %
0.13 %
0.30 %
0.50 %
0.079 %
0.025 %
0.025 %
0.025 %
0.027 %
0.043 %
0.043 %
0.083 %
0.13 %
0.30 %
0.50 %
5790B wideband | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 11 of 20
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Capacitance – Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.9999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 10.9999) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.061 % + 0.0078 nF
0.44 % + 0.0078 nF
0.42 % + 0.0078 nF
0.24 % + 0.0078 nF
0.23 % + 0.078 nF
0.23 % + 0.078 nF
0.23 % + 0.23 nF
0.23 % + 0.8 nF
0.23 % + 2.3 nF
0.24 % + 7.8 nF
0.34 % + 24 nF
0.38 % + 78 nF
0.38 % + 23 nF
0.37 % + 0.8 µF
0.37 % + 2.3 µF
0.37 % + 7.8 µF
0.59 % + 24 µF
0.86 % + 78 µF
Fluke 5520A
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
Capacitance – Generate
Fixed Points
10 pF
100 pF
1000 pF
10 nF
100 nF
1000 nF
1 pF
10 pF
(100, 1000) pF
(0.01, 0.1) µF
1 µF
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
(0.1, 0.4, 1) kHz
1 kHz
1 pF
0.016 %
0.01 %
6.5 µF/F
0.01 %
0.01 %
0.022 %
0.049 %
0.039 %
0.037 %
0.014 %
0.015 %
0.037 %
0.043 %
0.055 %
0.073 %
0.095 %
0.25 %
0.37 %
GenRad capacitors
Agilent
16380A/16380C
standard air capacitor
set, BNC 4 terminal
pair
Agilent
16380A/16380C
standard air capacitor
set, BNC 4 terminal
pair | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 12 of 20
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
Capacitance – Generate
(cont), Fixed Points
10 pF
100 pF
1000 pF
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
1 MHz
2 MHz
3 MHz
4 MHz
5 MHz
10 MHz
13 MHz
0.036 %
0.036 %
0.036 %
0.037 %
0.037 %
0.038 %
0.040 %
0.036 %
0.037 %
0.037 %
0.037 %
0.038 %
0.049 %
0.061 %
0.040 %
0.039 %
0.046 %
0.057 %
0.072 %
0.19 %
0.28 %
Agilent
16380A/16380C
standard air capacitor
set, BNC 4 terminal
pair
Capacitance – Measure
1 pF to 1 µF
10 pF
100 pF
400 pF
1600 pF
6.4 nF
25 nF
100 nF
400 nF
1600 nF
6 µF
25 µF
100 µF
1000 µF
1 kHz
100 kHz
1 kHz
61 µF/F
0.0023 pF
0.023 pF
0.093 pF
0.37 pF
0.0015 nF
0.0058 nF
0.023 nF
0.093 nF
0.37 nF
0.0014 µF
0.0058 µF
0.024 µF
0.25 µF
Andeen Hagerling
2500A capacitance
bridge
Genrad 1693 | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 13 of 20
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Capacitance – Measure
(cont)
200 µF to 110 mF
200 µF
300 µF
330 µF
700 µF
1.1 mF
2 mF
3 mF
3.3 mF
10.9 mF
20 mF
30 mF
33 mF
110 mF
210 µF/F
190 µF/F
180 µF/F
170 µF/F
160 µF/F
160 µF/F
160 µF/F
160 µF/F
160 µF/F
160 µF/F
160 µF/F
160 µF/F
180 µF/F
Fluke 5730A, 3458A
DC Current – Generate
Up to 220 µA
>220 µA to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
(>2.2 to 11) A
Up to 220 µA
>220 µA to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
(>2.2 to 11) A
(11 to 20) A
(20 to 100) A
40 µA/A + 6 nA
35 µA/A + 7 nA
35 µA/A + 40 nA
64 µA/A + 0.7 µA
60 µA/A + 12 µA
430 µA/A + 480 µA
2.9 µA/A + 0.21 nA
4.4 µA/A + 1.5 nA
8.0 µA/A + 38 nA
8.0 µA/A + 0.32 µA
3.0 µA/A + 0.31 µA
0.036 % + 480 µA
0.1 % + 0.75 mA
46 µA/A + 300 µA
Fluke 5730A
Fluke 5725A
Fluke 5730A
Fluke 8588A
Standard resistors
Fluke 5725A
Fluke 5520A
Valhalla 2555A,
Guildline 9211A
DC Current – Measure
Up to 1 nA
(>1 to 10) nA
(>10 to 100) nA
(>0.1 to 1) µA
(>1 to 10) µA
(>10 to 100) µA
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 mA to 1 A
(>1 to 10) A
(>10 to 100) A
130 µA/A + 0.33 pA
33 µA/A + 0.036 pA
4.8 µA/A + 0.047 pA
4.6 µA/A + 0.3 pA
9.2 µA/A + 0.3 pA
4.8 µA/A + 30 pA
5.6 µA/A + 0.3 nA
5.2 µA/A + 30 nA
5.3 µA/A + 0.3 µA
6.4 µA/A + 3 µA
20 µA/A + 30 µA
46 µA/A + 0.3 mA
HP 3458A precision
resistors | to 110 mF |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 14 of 20
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Resistance – Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(0.33 to 1.1) GΩ
34 µΩ/Ω + 0.78 mΩ
25 µΩ/Ω + 1.2 mΩ
23 µΩ/Ω + 1.1 mΩ
23 µΩ/Ω + 1.6 mΩ
24 µΩ/Ω + 1.6 mΩ
24 µΩ/Ω + 16 mΩ
23 µΩ/Ω + 16 mΩ
24 µΩ/Ω + 0.16 Ω
24 µΩ/Ω + 0.16 Ω
26 µΩ/Ω + 1.6 Ω
27 µΩ/Ω + 1.6 Ω
49 µΩ/Ω + 24 Ω
100 µΩ/Ω + 39 Ω
210 µΩ/Ω + 2 kΩ
400 µΩ/Ω + 2.4 kΩ
0.23 % + 78 kΩ
1.2 % + 0.39 MΩ
Fluke 5520A/SC600
DC Resistance –
Generate, Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
0.1 Ω
1 Ω
1.9 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
19 kΩ
100 kΩ
1 MΩ
10 MΩ
19 MΩ
83 µΩ/Ω
81 µΩ/Ω
23 µΩ/Ω
23 µΩ/Ω
10 µΩ/Ω
10 µΩ/Ω
8.1 µΩ/Ω
8.1 µΩ/Ω
8.1 µΩ/Ω
8.2 µΩ/Ω
9.6 µΩ/Ω
9.9 µΩ/Ω
16 µΩ/Ω
17 µΩ/Ω
35 µΩ/Ω
43 µΩ/Ω
120 µΩ/Ω
44 µΩ/Ω
2.5 µΩ/Ω
5.3 µΩ/Ω
2.0 µΩ/Ω
2.0 µΩ/Ω
1.5 µΩ/Ω
2.5 µΩ/Ω
1.5 µΩ/Ω
4.5 µΩ/Ω
4.1 µΩ/Ω
5.0 µΩ/Ω
11 µΩ/Ω
Fluke 5730A
Leeds & Northrup
4221, Fluke 742A-1,
Fluke 742A-1.9,
Fluke 742A-10, Fluke
742A-100, Fluke
742A-1k, Fluke
742A-10k, Fluke
742A-19k, Fluke
742A-100k, Fluke
742A-1M, Fluke
742A-10M, Fluke
742A-19M | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 15 of 20
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
DC Resistance – Measure
1 Ω
1.9 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
19 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
(>0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(200 to 2000) MΩ
(2 to 20) GΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
(20 to 200) GΩ
200 GΩ to 2 TΩ
0.001 Ω
0.01 Ω
0.1 Ω
1.0 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
9.2 µΩ/Ω
9.5 µΩ/Ω
4.2 µΩ/Ω
2.9 µΩ/Ω
2.3 µΩ/Ω
3.6 µΩ/Ω
2.2 µΩ/Ω
6.4 µΩ/Ω
6.2 µΩ/Ω
19 µΩ/Ω
22 µΩ/Ω
19 µΩ/Ω + 4 µΩ
9.9 µΩ/Ω + 14 µΩ
8.4 µΩ/Ω + 50 µΩ
8.2 µΩ/Ω + 500 µΩ
8.1 µΩ/Ω + 5 mΩ
8.4 µΩ/Ω + 50 mΩ
10 µΩ/Ω + 1 Ω
23 µΩ/Ω + 100Ω
69 µΩ/Ω + 1 kΩ
180 µΩ/Ω + 100 kΩ
0.015 % + 10 MΩ
0.30 %
0.24 %
0.17 %
0.23 %
6.6 µΩ/Ω
1.2 µΩ/Ω
0.68 µΩ/Ω
0.67 µΩ/Ω
0.67 µΩ/Ω
0.95 µΩ/Ω
1.2 µΩ/Ω
1.1 µΩ/Ω
1.6 µΩ/Ω
2.2 µΩ/Ω
14 µΩ/Ω
Fluke 8508A standard
resistors
Fluke 8508A
Guildline 6520
teraohmmeter
L&N 4214, 10 kΩ
L&N 4210, 1 Ω
MI 6000A bridge
MI 6010C bridge &
L&N working standard
resistors in oil bath.
Specific values are those
which fall within ± 50
parts in 10
6 of the
nominal value. Resistors
are normally calibrated
in an oil bath at 25 °C | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 16 of 20
Parameter/Equipment
Range
CMC2, 3, 4 (±)
Comments
DC Voltage – Generate
Fixed Points
(0 to 0.22) V
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
100 mV
1 V
10 V
100 V
1000 V
9.4 µV/V + 0.4 µV
3.8 µV/V + 0.7 µV
2.8 µV/V + 2.5 µV
2.8 µV/V + 4 µV
3.8 µV/V + 40 µV
4.8 µV/V + 400 µV
1.4 µV/V + 0.1 µV
1.1 µV/V + 0.1 µV
1.0 µV/V + 0.1 µV
1.1 µV/V + 0.1 µV
1.2 µV/V + 0.1 µV
Fluke 5730A
Fluke 732B
Fluke 752A
Fluke 8508A
5730A
DC Voltage – Measure
100 mV
1 V
10 V
100 V
1 kV
(0 to 200) mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
200 V to 1 kV
3.3 µV/V
1.2 µV/V
1.1 µV/V
1.1 µV/V
1.3 µV/V
6.0 µV/V + 0.1 µV
3.8 µV/V + 0.4 µV
3.7 µV/V + 4.0 µV
5.6 µV/V + 40 µV
5.7 µV/V + 500 µV
Fluke 732B
Fluke 752A
Fluke 8508A
Fluke 8508A
Inductance – Generate,
Fixed Points
50 µH
100 µH
1 mH
10 mH
20 mH
100 mH
1 H
5 H
10 H
0.09 %
0.04 %
0.02 %
0.02 %
0.20 %
0.02 %
0.02 %
0.04 %
0.06 %
GenRad 1482J
GenRad 1482B
GenRad 1482E
GenRad 1482H
GenRad 1482A
GenRad 1482L
GenRad 1482P
GenRad 1482R
GenRad 1482T
Inductance – Measure
(50 to 100) µH
100 µH to 1 mH
1 mH to 1 H
(1 to 5) H
(5 to 10) H
0.067 %
0.050 %
0.033 %
0.036 %
0.038 %
GenRad 1693 &
standard inductors | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 17 of 20
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Phase Angle – Generate
(0 to 360)°
(10 to 65) Hz
(>65 to 500) Hz
>500 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
0.14°
0.30°
0.59°
2.9°
5.8°
Fluke 5520A/SC600
Phase Angle – Measure
Voltage: Voltage
(0 to 360)°
10 mV to 630 V
Voltage: Current
(0 to 360)°
10 mV to 630 V
300 mA to 20 A
5 Hz to 2 kHz
(>2 to 5) kHz
(>5 to 10) kHz
(>10 to 50) kHz
>50 kHz to 1 MHz
5 Hz to 2 kHz
(>2 to 5) kHz
(>5 to 10) kHz
(>10 to 50) kHz
>50 kHz to 1 MHz
0.016°
0.022°
0.024°
0.024°
0.15°
0.017°
0.023°
0.025°
0.025°
0.16°
Clark Hess 6000A
Clark Hess 6000A
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
RF Power – Levelled Sine
Wave Flatness
(+20 to -30) dBm, 50 Ω
(-20 to -70) dBm, 50 Ω
100 kHz to 4.2 GHz
10 MHz to 18 GHz
0.056 dB + 1 Digit
0.073 dB + 1 Digit
Agilent HP 8482A,
power meter
Agilent HP 8481D,
power meter | 0 to 360 ° |
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 18 of 20
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
Harmonic Distortion –
Measure
(-95 to 0) dB
50 kHz to 2.1 GHz
2.7 dB
HP 8563E spectrum
analyzer
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Torque Wrenches
(1 to 10)ozf ∙in
(10 to 100) ozf∙in
(2.5 to 25) lbf∙in
(25 to 250) lbf∙in
(10 to 100) lbf∙ft
(75 to 750) lbf∙ft
0.66 % + 0.58R
0.64 % + 0.58R
0.62 % + 0.58R
0.65 % + 0.58R
0.63 % + 0.58R
0.67 % + 0.58R
A.W.S ITIO-10, ITIO-
100, ITI-25, ITI-250,
ITF-100, ITF-750
Torque Transducers
(1 to 40) ozf∙in
(1 to 100) lbf∙in
(>8 to 50) lbf∙ft
(50 to 1000) lbf∙ft
0.07 %
0.07 %
0.04 %
0.05 %
Weights, torque arms,
torque wheels
Shock Accelerometers –
Measuring Equipment
Shock Linearity
(20 to 2000) g
n
(2000 to 10 000) gn
2.0 %
2.1 %
Data acquisition card
w/ 9155D-525 shock
calibrator
Accelerometers
Voltage Sensitivity
(0.1 to 1000) mV/gn
Frequency Response
Relative to 100 Hz
100 Hz
(5 to 9) Hz
(10 to 99) Hz
(101 to 920) Hz
(921 to 5000) Hz
(5001 to 10 000) Hz
(10 to 15) kHz
(15 to 20) kHz
0.63 %
1.2 %
0.82 %
0.78 %
0.92 %
1.6 %
1.6 %
2.1 %
Data acquisition card
w/ 9155D-525 shock
calibrator | -95 to 0 dB |
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 19 of 20
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Accelerometers – (cont)
Charge Sensitivity,
(0.02 to 5000) pC/gn
Frequency Response
Relative to 100 Hz
100 Hz
(5 to 9) Hz
(10 to 99) Hz
(101 to 920) Hz
(921 to 5000) Hz
(5001 to 10 000) Hz
(10 to 15) kHz
(15 to 20) kHz
0.63 %
1.2 %
0.82 %
0.78 %
0.92 %
1.6 %
1.6 %
2.1 %
Data acquisition card
w/ 9155D-525 shock
calibrator
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature – Measure
(-200 to -38) °C
(-38 to 0) °C
(0 to 200) °C
(200 to 420) °C
0.025 °C
0.013 °C
0.022 °C
0.034 °C
Fluke 1502A W/5615-
12
VI. Time & Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Frequency – Measure
DC to 3 GHz
7.5 x 10-12 Hz/Hz + 0.58R
GPS controlled
frequency standard,
53131A
Frequency – Generate
DC to 3 GHz
10 MHz
7.5 x 10-12 Hz/Hz + 0.58R
7.5 x 10
-12 Hz/Hz
GPS controlled
frequency standard,
Keysight N5171B
Risetime – Measure
(17.5 to 350) ps
(0.25 to 2.5) V
1 kHz to 10 MHz
35 ps
Keysight 86100A,
86105B
_______________________________ | 0.02 to 5000 pC/gn |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.26) Revised 09/03/2025 Page 20 of 20
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
4 In the statement of CMC, R is the resolution of the unit under test; L is the numerical value of the nominal
length of the device measured in inches. In the statement of CMC, the value is defined as the percentage
of reading.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 21 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Hottinger Bruel & KjaerDuluth, GA · ~1,172 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Measuring Equipment
- Technical Maintenance, Inc. - DallasDallas, TX · ~20 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tektronix Inc. - DallasDallas, TX · ~20 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994