Registers refreshed 2026-11-08.See refresh dates
Costa Rica

INGENIERIA GAMBOA IGSA S.A, DBA IGSA METROLOGIA

Guadalupe, 300 Este y 50 Sur del Parque Central de Guadalupe, San Jose, Guadalupe, Costa Rica, San Jose, Costa Rica

Visit website
A2LA 7244.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 7244.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7244.01) 05/29/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INGENIERIA GAMBOA IGSA S.A, DBA IGSA METROLOGIA Guadalupe, 300 Este y 50 Sur Parque Central de Guadalupe San Jose, Guadalupe, COSTA RICA 92121 Jose Andres Gamboa Gonzalez Phone: +506 4034 3846 CALIBRATION Valid To: February 28, 2027 Certificate Number: 7244.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Mechanical Parameter/Equipment Range CMC2 (±) Comments Balance3 (0.001 to 200) g (200 to 35 000) g 0.22 g 0.23 g E-2 Class weights F-2 Class weights II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature3 – Incubators, Stoves, Ovens, Environmental Chambers, Refrigerators, Freezers & Similar Equipment Up to 300 °C 1.7 °C Thermocouple data logger
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7244.01) Revised 06/05/2025 Page 2 of 2 Parameter/Equipment Range CMC2 (±) Comments Liquid in Glass3 Temperature Gauge (Analog and Digital), Thermometer (Stick Type, Glass, Digital), RTDs & Thermocouples (-10 to 650) °C 0.78 °C Reference thermometer with RTD _______________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
-10 to 650 °C
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Guadalupe, 300 Este y 50 Sur del Parque Central de Guadalupe, San Jose, Guadalupe, Costa Rica, San Jose, CR

9.93274, -84.07967

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.