DDL, Inc.
10200 Valley View Rd, Suite 101, 55344, Eden Prairie, MN, United States
Visit website- Accredited standards
- 52
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 52 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM24
ASTM D618
ASTM D642
ASTM D880
ASTM D999
ASTM D4169
ASTM D4332
ASTM D4728
ASTM D5265
ASTM D5276
ASTM D5487
ASTM D6055
ASTM D6179
Show all 24
ASTM D6344
ASTM D6653
ASTM D7386
ASTM F88
ASTM F1140
ASTM F1886
ASTM F1929
ASTM F1980
ASTM F2054
ASTM F2096
ASTM F2825
ASTM F3039
ISO10
ISO 594-1Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements
ISO 594-2Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
ISO 2233Packaging - Complete, filled transport packages and unit loads - Conditioning for testing
ISO 7864Sterile hypodermic needles for single use - Requirements and test methods
ISO 7886-1Sterile hypodermic syringes for single use - Part 1: Syringes for manual use
ISO 9626Stainless steel needle tubing for the manufacture of medical devices - Requirements and test methods
ISO 10555-1Intravascular catheters - Sterile and single-use catheters - Part 1: General requirements
ISO 11070Sterile single-use intravascular introducers, dilators and guidewires
ISO 11608-1Needle-based injection systems for medical use - Requirements and test methods - Part 1: Needle-based injection systems
ISO 23908Sharps injury protection - Sharps protection mechanisms for single-use needles, introducers for catheters and needles used for blood testing, monitoring, sampling and medical substance administration - Requirements and test methods
ISO 8536 series8
ISO 8536-4Infusion equipment for medical use - Part 4: Infusion sets for single use, gravity feed
ISO 8536-8Infusion equipment for medical use - Part 8: Infusion sets for single use with pressure infusion apparatus
ISO 8536-9Infusion equipment for medical use - Part 9: Fluid lines for single use with pressure infusion equipment
ISO 8536-10Infusion equipment for medical use - Part 10: Accessories for fluid lines for single use with pressure infusion equipment
ISO 8536-11Infusion equipment for medical use - Part 11: Infusion filters for single use with pressure infusion equipment
ISO 8536-12Infusion equipment for medical use - Part 12: Check valves for single use
ISO 8536-13Infusion equipment for medical use - Part 13: Graduated flow regulators for single use with fluid contact
ISO 8536-14Infusion equipment for medical use - Part 14: Clamps and flow regulators for transfusion and infusion equipment without fluid contact
ISO 80369 series4
ISO 80369-3Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications
ISO 80369-6Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neural applications
ISO 80369-7Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications
ISO 80369-20Small-bore connectors for liquids and gases in healthcare applications - Part 20: Common test methods
ISO 11040 series3
ISO 11040-4Prefilled syringes - Part 4: Glass barrels for injectables and sterilized subassembled syringes ready for filling
ISO 11040-6Prefilled syringes - Part 6: Plastic barrels for injectables and sterilized subassembled syringes ready for filling
ISO 11040-8Prefilled syringes - Part 8: Requirements and test methods for finished prefilled syringes
USP3
USP 861
USP 871
USP 881
ASTM D4728; ASTM D999; ASTM D642; ASTM D880; ASTM D5487; ASTM D6055; ASTM D6179; ASTM D7386; ISTA 1A; ISTA 1B; ISTA 1C; ISTA 1D; ISTA 1E; ISTA 1G; ISTA 1H; ISTA 2A; ISTA 2B; ISTA 2C; ISTA 3A; ISTA 3B; ISTA 3E; ISTA 3F; ISTA 3H; ISTA 4AB; ISTA-6; ASTM D4332; ASTM F2825; ASTM F1980; ASTM D618; ISO 2233; ISTA 7D; ISTA 2A
ASTM F1980; ASTM F2825; ASTM D618; D4332; ISTA 7D; ISTA 2A; ISO 2233
ISO 8536-13; ISO 8536-14; ISO 9626; USP 861; USP 871; USP 881; ISO 594-1; ISO 594-2; ASTM F1929; ASTM F3039; ASTM F2096; ASTM F1140; ASTM F2054; ASTM F1886; ASTM F88; ASTM D4169; ASTM D6653; ASTM D5276; ASTM D6344; ASTM D5265
ISO 11040-8; ISO 11070; ISO 11608-1; ISO 23908; ISO 7864; ISO 7886-1
ISO 10555-1; ISO 80369-3; ISO 80369-6; ISO 80369-7; ISO 80369-20; ISO 11040-4; ISO 11040-6; ISO 11040-8
ISO 8536-4; ISO 8536-8; ISO 8536-9; ISO 8536-10; ISO 8536-11; ISO 8536-12
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active3561.01
The scope document we hold says it is valid until 2027-05-31.
Accredited scope, certificate 3561.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | shipping containers, medical pouches, medical trays, and medical devicesShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3561.01) 03/03/2025 Page 1 of 7
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
DDL, INC.
10200 Valley View Road, Suite 101
Eden Prairie, MN 55344
Suzette Glennon Phone: 952 283 2018
Email: suzette.glennon@ddltesting.com
MECHANICAL
Valid To: May 31, 2027 Certificate Number: 3561.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory at the location listed above , as well as the satellite laboratory location listed below, to perform
the following types of tests on shipping containers, medical pouches, medical trays, and medical devices:
Testing is completed for the following parameters in the calibrated ranges specified below:
Parameter Range
Load 0 to 50 (kN)
Displacement 0 to 35 (in)
Speed 0.04 to 120 (in/min)
Torque 0 to 25 (N·m)
Rotary displacement 0 to 360 (°)
Rotary Speed 0.1 to 60 (rpm)
Testing is completed for the following parameters in the calibrated ranges specified below Shock System:
Parameter Range
Load 1000 (lbs)
Acceleration
10G- 600G Drops
Stroke 1-40 (in)
Pulse Types
Square wave (Trapezoidal wave) drops from 10-70 (ms)
Half Since Drops from 2 -11 (ms) | See scope document |
| 2 | ISO 10555-1; ISO 80369-3; ISO 80369-6; ISO 80369-7; ISO 80369-20; ISO 11040-4; ISO 11040-6; ISO 11040-8 | Intravascular Catheters; Sterile and Single-use Catheters; Small-bore Connectors for Liquids and Gases in Healthcare Applications; Prefilled Syringes; Glass and Plastic Barrels for Injectables and Sterilized Subassembled Syringes Ready for Filing; Finished Prefilled Syringes | - |
| 3 | ISO 11040-8; ISO 11070; ISO 11608-1; ISO 23908; ISO 7864; ISO 7886-1 | - | - |
| 4 | ISO 8536-4; ISO 8536-8; ISO 8536-9; ISO 8536-10; ISO 8536-11; ISO 8536-12 | - | - |
| 5 | ISO 8536-13; ISO 8536-14; ISO 9626; USP 861; USP 871; USP 881; ISO 594-1; ISO 594-2; ASTM F1929; ASTM F3039; ASTM F2096; ASTM F1140; ASTM F2054; ASTM F1886; ASTM F88; ASTM D4169; ASTM D6653; ASTM D5276; ASTM D6344; ASTM D5265 | - | - |
| 6 | ASTM D4728; ASTM D999; ASTM D642; ASTM D880; ASTM D5487; ASTM D6055; ASTM D6179; ASTM D7386; ISTA 1A; ISTA 1B; ISTA 1C; ISTA 1D; ISTA 1E; ISTA 1G; ISTA 1H; ISTA 2A; ISTA 2B; ISTA 2C; ISTA 3A; ISTA 3B; ISTA 3E; ISTA 3F; ISTA 3H; ISTA 4AB; ISTA-6; ASTM D4332; ASTM F2825; ASTM F1980; ASTM D618; ISO 2233; ISTA 7D; ISTA 2A | Plastics | - |
| 7 | ASTM F1980; ASTM F2825; ASTM D618; D4332; ISTA 7D; ISTA 2A; ISO 2233 | - | See scope document |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
DDL, INC.
Eden Prairie, MN
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 3rd day of March 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 3561.01
Valid to May 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- ICC Evaluation ServiceElkhart, IN · ~697 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- John J Farber Technology and Innovation CenterRichmond, IN · ~899 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- CTL EngineeringColumbus, OH · ~1,016 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- Specialty Testing ServicesLeeds, AL · ~1,391 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
- Boyle Laboratories, LLCCharlotte, NC · ~1,514 kmA2LAShares 2 accredited methods and materialsASTM D618Plastics
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.