Registers refreshed 2026-11-08.See refresh dates
United States

The Fredericks Company

2400 Philmont Ave, 19006-6286, Huntingdon Valley, PA, United States

Visit website
A2LA 7104.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 7104.01 · 2 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7104.01) 9/16/2025 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 THE FREDERICKS COMPANY 2400 Philmont Ave Huntingdon Valley, PA 19006 Carl Lee Phone: 215 947 2500 CALIBRATION Valid To: October 31, 2027 Certificate Number: 7104.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1: I. Mechanical Parameter/Equipment Range CMC2, 3 (±) Comments Pressure – Calibration of Vacuum Gauges (1E1 to 1E3) torr (1E-1 to 1E1) torr (1E-2 to 1E-1) torr (1E-3 to 1E-2) torr (1E-4 to 1E-3) torr (1E-5 to 1E-4) torr (1E-6 to 1E-5) torr 1.5 % - 3.6E-2 torr 1.3 % + 1.6E-3 torr 1.1 % + 2.2E-4 torr 1.9 % + 5.1E-4 torr 3.9 % - 4.0E-7 torr 3.5 % + 8.8E-9 torr 3.4 % + 1.8E-8 torr Comparison method using spinning rotor gauge, ion gauge, or capacitance diaphragm gauge _________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
2ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2400 Philmont Ave, Huntingdon Valley, PA, 19006-6286, US

40.12261, -75.06350

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.