Registers refreshed 2026-11-20.See refresh dates
Spain

LABORATORIO REGIONAL AGROALIMENTARIO Y AMBIENTAL DE CASTILLA LA MANCHA

Avda. de Portugal, 42, 45600, Talavera de la Reina, Spain

ENAC 905/LE1706ISO/IEC 17025Register refreshed 46 days ago

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
ENAC certificate
1
Sites in our directory
2
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

4 lines
ENAC

ISO/IEC 17025

Active

905/LE1706

View scope

Accredited scope, certificate 905/LE1706

LineMethodMatrixRange
1UNE-EN ISO/IEC 17025:2017; PE/VR/04; Método Tipo I de CEA-ENAC-22; PE/VR/05; PE/VR/08; PE/SR/08Sangre de bovino; Suero de bovino, ovino, caprino y cérvidos; Suero de bovino, ovino y caprino-
2PE/PR/02; PE/PR/03; PE/PR/05; PE/PR/06; PE/SR/02; PE/SR/03; PE/SR/04Suero de suidos; Suero de rumiantes y suidos; Suero bovino, ovino, caprino y suido; Suero de ovino y caprino-
3PE/SR/07; Real Decreto 2611/1996; PE/EE/02; CEA-ENAC-22; PE/VR/06; PE/VR/07; UNE‐EN ISO 6579-1Suero de bovino; Sistema nervioso central bovino, ovino y caprino; Suero de aves; Heces animales; Calzas; Polvo; Toallitas; Fondos de caja; Piensos-
4UNE-CEN ISO/TR 6579-3; Manual terrestre de la OMSA Cap. 3.1.13Cultivo de Salmonella spp.; Sangre entera de rumiantes; Tejidos animales de bovino, caprino y suidos-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Avda. de Portugal, 42, Talavera de la Reina, 45600, ES

39.95779, -4.84752

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.