Starrett Kinemetric Engineering
26052 Merit Circle, Suite 103, 92653, Laguna Hills, CA, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 6274.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6274.01) 05/31/2025 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
STARRETT KINEMETRIC ENGINEEING, INC.
26052 Merit Circle, Suite 103
Laguna Hills, CA 92653
Debbie Donahue Phone: 949 348 1213
CALIBRATION
Valid To: April 30, 2027 Certificate Number: 6274.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 4:
I. Dimensional
Parameter/Equipment
Range
CMC2,4 (±)
Comments
Video Measurement
(AVR MVR)3
X, Y Axis
Z Axis
Up to 400 mm
Up to 15.75 in
Up to 200 mm
Up to 7.87 in
(0.7 + 0.0065L) µm
(28 + 6.5L) µin
(1 + 0.009L) µm
(39 + 9L) µin
Glass scale
Gage blocks
Video Measurement
(HDV300/400 Extended)
3
X, Y Axis
Up to 500 mm
Up to 21.65 in
(1.4 + 0.025L) µm
(55 + 25L) µin
Glass scale
Video Measurement
(HDV500)
3
X, Y Axis
Up to 500 mm
Up to 19.69 in
(1.3 + 0.013L) µm
(51 + 13L) µin
Glass scale | to 400 mm |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6274.01) 05/31/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2,4 (±)
Comments
Video Measurement
(AVX550)3
X, Y Axis
Z Axis
Up to 550 mm
Up to 21.65 in
Up to 250 mm
Up to 9.84 in
(1.8 + 0.005L) µm
(71 + 5L) µin
(2 + 0.005L) µm
(79 + 5L) µin
Glass scale
Gage blocks
2D Optical Inspection
(HB400/HD400)3
X, Y Axis
Up to 400 mm
Up to 15.75 in
(1.5 + 0.015L) µm
(59 + 15L) µin
Glass scale
Length (2D) Optical
Calibration Artifacts
Up to 200 mm
Up to 7.87 in
(1 + 0.006L) µm
(39 + 6L) µin
Video Measurement
System AVR300-
+M-Z-M3-2LED
S/S: GA-1164-3836-
0916
___________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
and millimeters.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | to 550 mm |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.