Registers refreshed 2026-11-20.See refresh dates
Japan

TOYO EMC Engineering

28-1, Hanashimashinden, Tsukuba-shi, Tsukuba, 3050875, Japan, Tsukuba, Japan

Visit website
A2LA 7749.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
14
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series11
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national

National versions in the same scope

KS C 9610-4-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national

National versions in the same scope

KS C 9610-4-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national

National versions in the same scope

KS C 9610-4-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national

National versions in the same scope

KS C 9610-4-5national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national

National versions in the same scope

KS C 9610-4-6national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national

National versions in the same scope

KS C 9610-4-8national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national

National versions in the same scope

KS C 9610-4-11probably the same standard; matched by number only

IEC 61000-4-34+1 national

National versions in the same scope

KS C IEC 61000-4-34probably the same standard; matched by number only

IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Other standards3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says IEC 55011. Probably the same standard; not checked against the EN document.

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7749.01

The scope document we hold says it is valid until 2028-05-31.

View scope

Accredited scope, certificate 7749.01

LineMethodMatrixRange
1EN IEC 55011; CISPR 11; EN55011; KS C9811; IEC 61000-4-2; EN 61000-4-2; EN IEC 61000-4-2; KS C 9610-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; KS C 9610-4-3; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; KS C 9610-4-6; IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; KS C 9610-4-11; IEC 61000-4-34; EN 61000-4-34; KS C IEC 61000-4-34; IEC 61000-4-39; EN 61000-4-39--
2SEMI F47; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; KS C9610-6-4; IEC 61326-1 (Class A); EN 61326-1 (Class A); EN IEC 61326-1 (Class A); EN IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-2; KS C 9610-6-2; IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6Semiconductor Processing Equipment-
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

28-1, Hanashimashinden, Tsukuba-shi, Tsukuba, 3050875, Japan, Tsukuba, JP

36.08333, 140.07728

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.