Trescal, Inc. - Pleasanton, CA

1047 Serpentine Lane, Suite 500, 94566, Pleasanton, CA, United States

Visit website
A2LA 2220.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 2220.01 · 15 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 20 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 2 of 14 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Voltage3 – Generate (0 to 329.9999) µV 330 µV to 3.299 999 V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1000) V 0.84 µV + 16 nV/mV 17 µV + 6 µV/V 88 µV + 7 µV/V 0.55 mV + 14 µV/V 2.6 mV + 14 µV/V Fluke 5522A DC Voltage3 – Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 0.33 µV + 17 µV/V 0.52 µV + 8 µV/V 8.8 µV + 8.1 µV/V 35 µV + 10 µV/V 1.2 mV + 11 µV/V Agilent 3458A DC Current3 – Generate (0 to 329.999) µ A 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A 16 nA + 0.12 nA/µA 40 nA + 78 nA/mA 0.2 µA + 78 nA/mA 2 µA + 78 nA/mA 33 µA + 0.16 mA/A 0.36 mA + 0.3 mA/A 0.48 mA + 0.38 mA/A 9.1 mA + 0.78 mA/A Fluke 5522A DC Current3 – Measure (0 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 41 pA + 89 µA/A 70 pA + 21 µA/A 0.4 nA + 19 µA/A 0.83 nA + 17 µA/A 5.8 nA + 19 µA/A 0.053 µA + 16 µA/A 0.53 µA + 32 µA/A 10 µA + 100 µA/A Agilent 3458A DC High Voltage – Measure (1 to 10) kV 0.037 % Vitrek 4700 AC High Voltage – Measure (1 to 10) kV, 60 Hz 0.14 % Vitrek 4700
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 3 of 14 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance3 – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1099.999) Ω (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (330 to 1099.999) kΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 1.1 mΩ + 25 µΩ/Ω 1.4 mΩ + 31 µΩ/Ω 2.6 mΩ + 18 µΩ/Ω 4.4 mΩ + 23 µΩ/Ω 9.7 mΩ + 24 µΩ/Ω 42 mΩ + 24 µΩ/Ω 98 mΩ + 24 µΩ/Ω 0.42 Ω + 24 µΩ/Ω 0.97 Ω + 24 µΩ/Ω 8.3 Ω + 25 µΩ/Ω 14 Ω + 25 µΩ/Ω 90 Ω + 47 µΩ/Ω 0.39 kΩ + 0.1 mΩ/Ω 4.2 kΩ + 0.19 mΩ/Ω 15 kΩ + 0.39 mΩ/Ω 0.34 MΩ + 2.3 mΩ/Ω 4.2 MΩ + 12 mΩ/Ω Fluke 5522A Resistance3 – Generate, Fixed Point, Calibrate Thermometer DRO 25 Ω 75 Ω 100 Ω 200 Ω 400 Ω 40 µΩ 0.11 mΩ 0.14 mΩ 0.39 mΩ 0.61 mΩ Hart 5420-25 MI 9331-75 Hart 5420-100 Hart 5420-200 Hart 5420-400 Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 55 µΩ + 15 µΩ/Ω 0.52 mΩ + 13 µΩ/Ω 0.53 mΩ + 10 µΩ/Ω 5.3 mΩ + 10 µΩ/Ω 53 mΩ + 11 µΩ/Ω 2.3 Ω + 17 µΩ/Ω 0.1 kΩ + 55 µΩ/Ω 1 kΩ + 0.52 mΩ/Ω 10 kΩ + 5.1 mΩ/Ω Agilent 3458A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 4 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (1 to 32.999) mV (33 to 329.999) mV 330 mV to 3.299 99 V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 5.7 µV + 0.62 µV/mV 6.1 µV + 0.1 µV/mV 6.1 µV + 0.14 µV/mV 8.1 µV + 0.71 µV/mV 16 µV + 2.6 µV/mV 46 µV + 6.2 µV/mV 53 µV + 6 µV/mV 20 µV + 0.22 µV/mV 27 µV + 77 nV/mV 17 µV + 0.11 µV/mV 37 µV + 0.27 µV/mV 50 µV + .061 µV/mV 0.11 mV + 1.5 µV/mV 0.15 mV + 1.4 µV/mV 0.15 mV + 0.22 mV/V 0.13 mV + 0.11 mV/V 0.13 mV + 0.14 mV/V 0.21 mV + 0.21 mV/V 0.39 mV + 0.51 mV/V 1.1 mV + 1.9 mV/V 1.8 mV + 1.7 mV/V 1.8 mV + 0.22 mV/V 1.6 mV + 99 µV/V 2 mV + 0.16 mV/V 2.4 mV + 0.24 mV/V 5 mV + 0.66 mV/V 16 mV + 0.12 mV/V 18 mV + 0.14 mV/V 19 mV + 0.17 mV/V 48 mV + 0.16 mV/V 93 mV + 1.5 mV/V 96 mV + 0.22 mV/V 85 mV + 0.18 mV/V 96 mV + 0.22 mV/V Fluke 5520A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 5 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (0.1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.0061 mV + 0.0003 mV/mV 0.0041 mV + 0.0002 mV/mV 0.0042 mV + 0.0003 mV/mV 0.0049 mV + 0.001 mV/mV 0.009 mV + 0.005 mV/mV 0.045 mV + 0.04 mV/mV 0.012 mV + 0.000 07 mV/mV 0.0027 mV + 0.000 07 mV/mV 0.011 mV + 0.000 14 mV/mV 0.012 mV + 0.0003 mV/mV 0.017 mV + 0.0008 mV/mV 0.047 mV + 0.003 mV/mV 0.12 mV + 0.01 mV/mV 3.8 mV + 0.01 mV/mV 0.000 12 V + 0.000 07 V/V 0.0001 V + 0.000 07 V/V 0.000 11 V + 0.000 14 V/V 0.000 12 V + 0.0003 V/V 0.000 17 V + 0.0008 V/V 0.000 47 V + 0.003 V/V 0.0012 V + 0.010 V/V 0.038 V + 0.015 V/V 0.0012 V + 0.000 07 V/V 0.001 V + 0.000 07 V/V 0.001 V + 0.000 14 V/V 0.0012 V + 0.0003 V/V 0.0017 V + 0.0008 V/V 0.0047 V + 0.003 V/V 0.012 V + 0.01 V/V 0.38 V + 0.015 V/V 0.013 V + 0.0002 V/V 0.011 V + 0.0002 V/V 0.011 V + 0.0002 V/V 0.013 V + 0.000 35 V/V 0.021 V + 0.0012 V/V 0.057 V + 0.004 V/V 0.17 V + 0.015 V/V 0.098 V + 0.0004 V/V 0.084 V + 0.0004 V/V 0.098 V + 0.0006 V/V 0.14 V + 0.0012 V/V 0.27 V + 0.003 V/V Agilent 3458A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 6 of 14 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (29 to 329.99) µA 330 µA to 3.2999 mA (3.3 to 32.999) mA (33 to 329.99) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.14 µA + 1.5 nA/µA 0.13 µA + 1.1 nA/µA 0.13 µA + 0.92 nA/µA 0.2 µA + 2.3 nA/µA 0.34 µA + 6.2 nA/µA 0.68 µA + 1.2 nA/µA 0.77 µA + 1.5 µA/mA 0.59 µA + 0.93 µA/mA 0.55 µA + 0.73 µA/mA 0.78 µA + 1.5 µA/mA 2.9 µA + 1.5 µA/mA 3.3 µA + 7.7 µA/mA 7.5 µA + 1.4 µA/mA 5.3 µA + 0.66 µA/mA 4.5 µA + 0.27 µA/mA 5.2 µA + 0.58 µA/mA 8.3µA + 1.5 µA/mA 14 µA + 3.1 µA/mA 75 µA + 1.4 µA/mA 55 µA + 0.66 µA/mA 47 µA + 0.26 µA/mA 75 µA + 0.75 µA/mA 0.13 mA + 1.5 µA/mA 0.26 mA + 3.1 µA/mA 0.6 mA + 1.3 mA/A 0.33 mA + 0.31 mA/A 2.3 mA + 4.6 mA/A 10 mA + 19 mA/A 1.6 mA + 1.5 mA/A 0.65 mA + 0.66 mA/A 5.9 mA + 4.7 mA/A 25 mA + 19 mA/A 3.3 mA + 0.72 mA/A 4.1 mA + 0.95 mA/A 71 mA + 23 mA/A 15 mA + 1.7 mA/A 18 mA + 1.8 mA/A 0.26 A + 23 mA/A Fluke 5520A
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 7 of 14 Parameter/Range Frequency CMC2 ,4 (±) Comments AC Current3 – Measure (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz 57 nA + 4 mA/A 45 nA + 1.5 mA/A 40 nA + 0.64 mA/A 0.000 43 mA + 0.0041 mA/mA 0.000 31 mA + 0.0016 mA/mA 0.000 26 mA + 0.000 67 mA/mA 0.000 25 mA + 0.000 37 mA/mA 0.000 26 mA + 0.000 67 mA/mA 0.000 63 mA + 0.0042 mA/mA 0.0018 mA + 0.0056 mA/mA 0.0024 mA + 0.0041 mA/mA 0.0023 mA + 0.0016 mA/mA 0.0023 mA + 0.000 67 mA/mA 0.0023 mA + 0.000 37 mA/mA 0.0023 mA + 0.000 67 mA/mA 0.0045 mA + 0.0041 mA/mA 0.016 mA + 0.0056 mA/mA 0.042 mA + 0.004 mA/mA 0.03 mA + 0.0015 mA/mA 0.025 mA + 0.0006 mA/mA 0.024 mA + 0.0003 mA/mA 0.025 mA + 0.0006 mA/mA 0.062 mA + 0.004 mA/mA 0.18 mA + 0.0055 mA/mA 0.00042 A + 0.0041 A/A 0.0003 A + 0.0017 A/A 0.000 26 A + 0.0009 A/A 0.000 27 A + 0.0011 A/A 0.000 37 A + 0.0031 A/A 0.000 92 A + 0.01 A/A Agilent 3458A
5 to 100 µA
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 8 of 14 Parameter/Range Frequency CMC2, 4, 7 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF 0.4 to 1.0999) nF (1.1 to 3.299) nF (3.3 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz Up to 50 Hz Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz 8.5 pF + 3.8 pF/nF 9.4 pF + 3.9 pF/nF 12 pF + 3.9 pF/nF 15 pF + 2 pF/nF 0.1 nF + 1.9 pF/nF 0.14 nF + 1.9 pF/nF 0.45 nF + 1.9 pF/nF 1.4 nF + 1.9 nF/µF 4.4 nF + 1.9 nF/µF 14 nF + 1.9 nF/µF 58 nF + 3.1 nF/µF 0.19 µF + 3.5 nF/µF 0.62 µF + 3.5 nF/µF 1.9 µF + 3.5 µF/mF 6.8 µF + 3.4 µF/mF 38 µF + 2.4 µF/mF 87 µF + 5.8 µF/mF 0.36 mF + 8.5 µF/mF Fluke 5520A Capacitance – Measure See table below (CMC’s can be interpolated between cardinal frequencies) See table below IET DE-6000 LCR meter 100 Hz 120 Hz 1 kHz 10 kHz 100 kHz Up to 2000 pF ---- ---- 2.3 % 0.47 % 0.87 % (2 to 20) nF 2.3 % 2.3 % 0.24 % 0.36 % 0.72 % (20 to 200) nF 0.36 % 0.36 % 0.24 % 0.36 % 0.72 % 200 nF to 2 µF 0.37 % 0.37 % 0.26 % 0.72 % 2.4 % (2 to 20) µF 0.36 % 0.36 % 0.72 % 1.5 % 3.8 % (20 to 200) µF 0.72 % 0.72 % 1.3 % 3.8 % 200 µF to 2 mF 1.3 % 1.3 % 1.8 % ---- ----
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 9 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 Type B Type C Type E Type J Type K Type N (250 to < 350) °C (350 to < 445) °C (445 to < 580) °C (580 to < 780) °C (750 to < 1000) °C (1000 to 1820) °C (0 to < 250) °C (250 to < 1000) °C (1000 to < 1500) °C (1500 to < 1800) °C (1800 to < 2000) °C (2000 to < 2250) °C (2250 to 2315) °C (-270 to < -245) °C (-245 to < -195) °C (-195 to < -155) °C (-155 to < -90) °C (-90 to < 15) °C (15 to < 890) °C (890 to 1000) °C (-210 to < -180) °C (180 to < -120) °C (-120 to < -50) °C (-50 to < 990) °C (990 to 1200) °C (-270 to < -255) °C (-255 to < -195) °C (-195 to < -115) °C (-115 to < -55) °C (-55 to < 1000) °C (1000 to 1372) °C (-270 to < -260) °C (-260 to < -200) °C (-200 to < -140) °C (-140 to < -70) °C (-70 to < 25) °C (25 to < 160) °C (160 to 1300) °C 0.95 °C 0.74 °C 0.58 °C 0.46 °C 0.38 °C 0.3 °C 0.21 °C 0.17 °C 0.19 °C 0.22 °C 0.24 °C 0.3 °C 0.33 °C 1.2 °C 0.18 °C 0.1 °C 0.082 °C 0.073 °C 0.063 °C 0.07 °C 0.12 °C 0.1 °C 0.083 °C 0.073 °C 0.07 °C 2.2 °C 0.7 °C 0.12 °C 0.092 °C 0.073 °C 0.083 °C 5 °C 1 °C 0.23 °C 0.16 °C 0.13 °C 0.11 °C 0.1 °C Ectron 1140A
to 1820 °C
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 10 of 14 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – (cont) Type R Type S Type T (-50 to < -30) °C (-30 to < 45) °C (45 to < 160) °C (160 to < 380) °C (380 to < 775) °C (775 to 1768) °C (-50 to < -30) °C (-30 to < 45) °C (45 to < 105) °C (105 to < 310) °C (310 to < 615) °C (615 to 1768) °C (-270 to < -255) °C (-255 to < -240) °C (-240 to < -210) °C (-210 to < -150) °C (-150 to < -40) °C (-40 to < 100) °C (100 to 400) °C 0.65 °C 0.55 °C 0.41 °C 0.31 °C 0.27 °C 0.23 °C 0.62 °C 0.56 °C 0.41 °C 0.34 °C 0.3 °C 0.27 °C 1.8 °C 0.49 °C 0.3 °C 0.18 °C 0.12 °C 0.085 °C 0.08 °C Ectron 1140A III. Fluid Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Air Flow Rate – Measure (10 to 100) sccm (0.1 to 1) slm (1 to 10) slm (10 to 100) slm (40 to 400) slm 0.41 % of rdg 0.41 % of rdg 0.41 % of rdg 0.41 % of rdg 0.41 % of rdg DHI Molbloc Air Flow Rate – Measure3 (5 to 500) sccm 500 sccm to 50 slm 0.52 % of rdg 0.57 % of rdg Sierra Instruments primary gas flow calibrator
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 11 of 14 IV. Mechanical Parameter/Equipment Range CMC2, 5, 7 (±) Comments Torque Wrenches 4 ozf-in to 250 lbf-ft 0.37 % of rdg Torque transducers Pressure – Measure3 ± (0 to 7.5) inH2O ± (7.5 to 30) inH2O Up to 15 psia (-14.5 to 0) psig (0 to 40) psig (40 to 100) psig (100 to 200) psig (200 to 500) psig (0 to 1000) psig 0.0004 inH2O 0.0064 % of rdg 0.002 psi 0.002 psi 0.002 psi 0.0055 % of rdg 0.01 psi 0.005 % of rdg 0.58 psi Ruska 7250LP Ruska 7252i Ashcroft pressure module Scales3 Up to 1200 lbs 0.82R NIST F Class weights Balances3 Up to 45 kg Matrix value x R Class 1 weights Unit Under Test Resolution 0.000 01 g 0.0001 g 0.001 g 0.01 g 0.1 g 1 & 10 g 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 0.85 100 mg 200 mg 0.83 500 mg 0.86 1 g 0.83 2 g 0.87 0.82 5 g 0.91 10 g 1.1 20 g 50 g 1.2 100 g 2.0 200 g 6.7 1.1 500 g 1.2 1 kg 1.8 2 kg 9.5 1.3 5 kg 1.5 0.83 10 kg 5.8
4 to 250 lbf-ft
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 12 of 14 Parameter/Equipment Range CMC2, 7 (±) Comments Balances3 (cont) Up to 45 kg Matrix value x R Class 1 weights Unit Under Test Resolution 0.000 01 g 0.0001 g 0.001 g 0.01 g 0.1 g 1 & 10 g 20 kg 0.82 30 kg 40 kg 45 kg V. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Relative Humidity – Measuring Equipment (10 to 95) % RH @ (0 to 70) °C (0 to 70) °C 0.51 % RH + 0.000 39 % RH/% RH + 0.000 051 % RH/°C 0.074 °C Thunder Scientific 2500 generator Relative Humidity – Measure 3 (11 to 90) % RH (90 to 95) % RH 1.4 % RH 2.1 % RH Vaisala MI70 w/ HMP76B Temperature3 – Measure (-197 to < 0) °C (0 to 660) °C (660 to 960) °C 0.0037 °C - 0.000 000 45 x ΔTChange from -197 0.0027 °C + 0.000 0002 x ΔTChange from 0 0.42 °C + 0.000 39 x ΔTChange from 660 1595A thermometer, 5699 PRT Type “S” thermocouple Temperature3 – Measuring Equipment -195.7 °C (-80 to 660) °C (660 to 770) °C (770 to 1100) °C 0.0046 °C 0.0042 °C + 0.000 019 x ΔTChange from -80 0.63 °C + 0.000 75 x ΔTChange from 770 0.51 °C + 0.000 68 x ΔTChange from -80 1595A thermometer, 5699 PRT, type S thermocouple probe, LN2 comparator, calibration wells/baths
to 45 kg
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 13 of 14 VI. Time & Frequency Parameter/Equipment Range CMC2, 5, 7 (±) Comments Frequency – Measuring Equipment 10 mHz to 2 MHz 5.8 µHz + 2.9 µHz/Hz Fluke 5520A Stopwatches, Timers & Timing Devices Time Base Method Comparison ± (0 to 19.99) sec/day Up to 86 400 sec 0.037 sec/day 0.0053 % Timometer Chronograph Rotational Speed3 Optical Contact (Mechanical) (5 to 200 000) rpm (5 to 20 000) rpm 0.18 % 0.066 % Monarch PLT200 ____________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification.
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2220.01) Revised 1/29/2026 Page 14 of 14 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 In the statement of CMC, R is the resolution of the unit under test and percentages are percent of reading unless otherwise indicated.
15ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1047 Serpentine Lane, Suite 500, Pleasanton, CA, 94566, US