United States

Precision Measurements

20 Hagerty Blvd, Suite 1, 19382, West Chester, PA, United States

Visit website
A2LA 7185.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
20
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 20 scope lines.

A2LA certificate 7185.01 · 20 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994Conductivity Solutions-
2QAI-MXX procedures; NIST Monograph 180; QAI-M18; QAI-M10-See scope document
3-thermocouple
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 3 of 19 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2 (±) Comments Temperature Calibration, Indication, & Control Equipment 3 Used with Thermocouple Type E Type J Type K Type N Type R Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.56 °C 0.19 °C 0.17 °C 0.19 °C 0.24 °C 0.31 °C 0.19 °C 0.17 °C 0.20 °C 0.26 °C 0.37 °C 0.21 °C 0.19 °C 0.29 °C 0.45 °C 0.45 °C 0.25 °C 0.22 °C 0.21 °C 0.31 °C 0.63 °C 0.39 °C 0.37 °C 0.45 °C 0.52 °C 0.40 °C 0.41 °C 0.51 °C 0.7 °C 0.27 °C 0.19 °C 0.17 °C Fluke 5520A electrical simulation of thermocouple output; GIDEP procedures OEM procedures
See scope document
4GIDEP procedures; OEM proceduresRTDSee scope document
5-RTD
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 5 of 19 Parameter/Equipment Range CMC 2, 5 (±) Comments Temperature Calibration, Indication & Control Equipment used with RTD 3 (cont) Pt 3926, 100 Ω Ni 385, 120 Ω Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.06 °C 0.06 °C 0.07 °C 0.09 °C 0.09 °C 0.11 °C 0.07 °C 0.07 °C 0.12 °C 0.4 °C Fluke 5520A, electrical simulation of RTD output; GIDEP procedures, OEM procedures DC Voltage – Generate3 Up to 330 mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 20 µV/V + 1.8 µV 11 µV/V + 11 µV 11 µV/V + 23 µV 18 µV/V + 1.1 mV 18 µV/V + 4 mV Fluke 5520A QAI-EXX procedures OEM procedures DC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V (1 to 10) kV (10 to 40) kV 6.3 µV/V + 0.5 µV 3.7 µV/V + 0.3 µV 3.7 µV/V + 1 µV 5.8 µV/V + 10 µV 5.9 µV/V + 0.1 mV 0.4 mV/V + 40 mV 27 mV/V + 0.1 V Fluke 8508A QAI-EXX procedures OEM procedures Vitrek 4700 QAI-EXX procedures OEM procedures Fluke 87V with 80K- 40 QAI-EXX procedures OEM procedures
See scope document
6QAI-EXX procedures; OEM procedures--
7QAI-EXX procedures; OEM procedures-See scope document
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 8 of 19 Parameter/Equipment Range CMC2, 5 (±) Comments Inductance – Measure 3 (0.1 to 1) mH (1 to 10) mH (10 to 100) mH (0.1 to 1) H (1 to 10) H (10 to 100) H (0.1 to 1) kH 1 mH/H + 1.5 µH 1 mH/H + 15 µH 1 mH/H + 0.15 mH 1 mH/H + 1.4 mH 1 mH/H + 15 mH 1 mH/H + 0.17 H 5 mH/H + 1.9 H Fluke PM6304 QAI-EXX procedures OEM procedures Parameter/Range Frequency CMC 2, 5 (±) Comments AC Voltage –Measure3 200 mV to 2 V (2 to 20) V (20 to 200) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 160 µV/V + 120 µV 130 µV/V + 21 µV 110 µV/V + 21 µV 80 µV/V + 21 µV 120 µV/V + 21 µV 230 µV/V + 41 µV 600 µV/V + 210 µV 3.1 mV/V + 2.1 mV 11 mV/V + 20 mV 160 µV/V + 1.3 mV 130 µV/V + 210 µV 97 µV/V + 210 µV 81 µV/V + 210 µV 120 µV/V + 210 µV 230 µV/V + 410 µV 580 µV/V + 2.1 mV 3.1 mV/V + 20 mV 11 mV/V + 0.2 V 160 µV/V + 13 mV 130 µV/V + 2.1 mV 97 µV/V + 2.1 mV 79 µV/V + 2.1 mV 120 µV/V + 2.1 mV 230 µV/V + 4.1 mV 580 µV/V + 21 mV 3.1 mV/V + 200 mV 11 mV/V + 2 V Fluke 8508A QAI-EXX procedures OEM procedures
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 9 of 19 Parameter/Range Frequency CMC 2, 5 (±) Comments AC Voltage – Measure3 (cont) (200 to 1000) V (1 to 10) kV (1 to 10) Hz (10 to 40) Hz 40 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 mHz to 10 Hz (10 to 65) Hz (65 to 200) Hz (200 to 450) Hz 1.6 mV/V + 71 mV 130 µV/V + 21 mV 170 µV/V + 21 mV 400 µV/V + 41 mV 670 µV/V + 0.2 V 1.4 mV/V + 0.2 V 1.4 mV/V + 0.2 V 1.4 mV/V + 0.2 V 4.7 mV/V + 0.2 V Fluke 8508A QAI-EXX procedures OEM procedures Vitrek 4700 QAI-EXX procedures OEM procedures AC Current – Measure 3 (20 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 510 µA/A + 20 nA 560 µA/A + 20 nA 750 µA/A + 20 nA 4.1 mA/A + 20 nA 340 µA/A + 0.2 µA 320 µA/A + 0.2 µA 720 µA/A + 0.2 µA 4.1 mA/A + 0.2 µA 340 µA/A + 2 µA 340 µA/A + 2 µA 730 µA/A + 2 µA 4.1 mA/A + 2 µA 340 µA/A + 20 µA 320 µA/A + 20 µA 640 µA/A + 20 µA 630 µA/A + 0.2 mA 940 µA/A + 0.2 mA 3.1 mA/A + 0.2 mA 830 µA/A + 2 mA 2.7 mA/A + 2 mA Fluke 8508A QAI-EXX procedures OEM procedures
10QAI-EXXAC CurrentSee scope document
11QAI-EXX; GIDEP; OEM--
12QAI-EXX; GIDEPAC VoltageSee scope document
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 13 of 19 IV. Electrical – RF/Microwave Parameter/Range Frequency CMC 2, 7 (±) Comments RF Power – Generate3 4 nW to 100 mW 1 pW to 10 mW 100 µW to 100 mW 100 pW to 100 µW (1 to 100) pW 100 pW to 100 mW (1 to 100) pW 1 mHz to 100 kHz 100 kHz to 10 MHz 10 MHz to 2 GHz (2 to 20) GHz (2 to 20) GHz (2 to 20) GHz (20 to 31.8) GHz (20 to 31.8) GHz 48 mW/W 150 mW/W 210 mW/W 210 mW/W 240 mW/W 260 mW/W 260 mW/W 590 mW/W GIDEP procedures OEM procedures Hewlett Packard 3325B Agilent E8257D RF Power – Measure 3 10 µW to 1 W 100 pW to 10 µW 100 kHz to 26.5 GHz 10 MHz to 18 GHz 35 mW/W 46 mW/W Hewlett Packard 8481D Agilent E4416A N8482A N8481A 8485A RF Attenuation 3 – Measure (TRFL) 100 µW to 1 mW (10 to 100) µW (1 to 10) µW 100 nW to 1 µW (10 to 100) nW (1 to 10) nW 100 pW to 1 nW (10 to 100) pW (1 to 10) pW 100 fW to 1 pW 100 µW to 1 mW (10 to 100) µW (1 to 10) µW 100 nW to 1 µW (10 to 100) nW (1 to 10) nW 100 pW to 1 nW (10 to 100) pW (1 to 10) pW 100 fW to 1 pW 2.5 MHz to 1.3 GHz (200 Hz BW) 1.3 GHz to 26.5 GHz (200 Hz BW) 12 mW/W 17 mW/W 21 mW/W 26 mW/W 40 mW/W 45 mW/W 50 mW/W 55 mW/W 70 mW/W 74 mW/W 12 mW 17 mW/W 21 mW/W 26 mW/W 40 mW/W 45 mW/W 50 mW/W 55 mW/W 120 mW/W 120 mW/W Hewlett Packard 8902A GIDEP procedures OEM procedures
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 14 of 19 Parameter/Range Frequency CMC 2, 7 (±) Comments Phase Modulation – Measure 150 kHz to 10 MHz 10 MHz to 1.3 GHz (1.3 to 26.5) GHz 4 % of reading + 0.5 rad 3 % of reading + 0.5 rad 4 % of reading + 0.5 rad Hewlett Packard 8902A GIDEP procedures OEM procedures Amplitude Modulation – Measure Depths: 5 % to 99 % Depths: to 99 % Depths: 5 % to 99 % Depths: to 99 % Depths: 5 % to 99 % Depths: to 99 % 150 kHz to 10 MHz 150 kHz to 10 MHz 10 MHz to 1.3 GHz 10 MHz to 1.3 GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 2.1 % of reading + 0.012 % AM 3.1 % of reading + 0.012 % AM 1.1 % of reading + 0.012 % AM 3.1 % of reading + 0.012 % AM 2.1 % of reading + 0.012 % AM 3.1 % of reading + 0.012 % AM Hewlett Packard 8902A GIDEP procedures OEM procedures Frequency Modulation – Measure Rate: 20 Hz to 200 kHz Rate: 50 Hz to 100 kHz Rate: 20 Hz to 200 kHz Rate: 50 Hz to 100 kHz 250 kHz to 10 MHz 10 MHz to 1.3 GHz 10 MHz to 1.3 GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 20 mHz/Hz + 0.12 kHz 51 mHz/Hz + 20 Hz 11 mHz/Hz + 20 Hz 51 mHz/Hz + 20 Hz 11 mHz/Hz + 20 Hz Hewlett Packard 8902A GIDEP procedures OEM procedures V. Fluid Quantities Parameter/Equipment Range CMC 2, 7 (±) Comments Liquid Flow – Measuring Equipment 3 Up to 80 gal/min (80 to 800) gal/min 0.31 % of reading + 0.023 gal/min 0.19 % of reading + 0.016 gal/min Micro Motion DSH100H134P DS300S155 GIDEP procedures OEM procedures
15-Gas Flow; Scales & Balances; Load Cells/Force Gauges; Load Cells
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 15 of 19 Parameter/Equipment Range CMC 2, 7 (±) Comments Gas Flow – Measuring Equipment (1 to 10) SCCM (10 to 100) SCCM (100 to 1000) SCCM (1 to 10) SLPM (2.5 to 25) SLPM (10 to 100) SLPM (50 to 500) SLPM 0.4 % of reading + 0.000 58 SCCM 0.4 % of reading + 0.0058 SCCM 0.4 % of reading + 0.058 SCCM 0.4 % of reading + 0.58 SCCM 0.47 % of reading + 5.8 SCCM 0.5 % of reading + 5.8 SCCM 0.47 % of reading + 15 SCCM Fluke MolBloc system GIDEP procedures OEM procedures VI. Mechanical Parameter/Equipment Range CMC 2 (±) Comments Scales & Balances3 (1 to 500) mg 1 g to 1 kg (1 to 10) kg (1 to 1000) lb 5.8 µg/g + 5.9 µg 2.1 µg/g + 64 µg 3.3 µg/g + 23 mg 0.012 % of reading + 0.2 lb Class 1 Weights QAI-A04 Class F Weights NIST HB 44 Load Cells/Force Gauges 3 (1 to 600) lbf 0.0013 % of reading + 0.0066 lbf Class F Weights QAI-M11 Load Cells 3 (Tension, Compression) (500 to 5000) N (200 to 2) N (20 to 1779) N 2.4 mN/N 5 mN/N 5 mN/N Class F Weights QAI-M11
See scope document
16OIML R111; GIDEP proceduresWeights; Pressure; Torque-
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 17 of 19 Parameter/Equipment Range CMC 2, 7 (±) Comments Torque – Measure3 (2 to 20) ozfꞏ in (1 to 10) lbfꞏ in (25 to 250) lbfꞏ in (10 to 100) lbfꞏ ft (25 to 250) lbfꞏ ft 0.63 % of reading + 0.001 ozfꞏ in 0.63 % of reading + 0.001 lbfꞏin 0.6 % of reading + 0.01 lbfꞏ in 0.63 % of reading + 0.0058 lbfꞏ ft 0.7 % of reading + 0.01 lbfꞏ ft Mountz BMX20Z BMX10i BMX250i BMX100F BMX 250F QAI –M04 Torque – Measure (10 to 100) lbfꞏ in (100 to 1000) lbfꞏ ft 0.12 % of reading + 0.02 lbfꞏ in 0.12 % of reading + 0.2 lbfꞏ ft AKO TDS QAI –M04 VII. Thermodynamics Parameter/Equipment Range CMC 2, 7 (±) Comments Temperature measurement with RTD 3 -196 °C -80 °C (-40 to 125) °C (125 to 300) °C 0.04 °C 0.04 °C 0.04 °C 0.04 °C Kaye IRTD: Liquid nitrogen Dry ice Temperature baths QAI-T01 Relative Humidity3 (0 to 25) % RH (25 to 75) % RH (75 to 95) % RH (10 to 95) % RH 1.3 % RH 0.77 % RH 1.3 % RH 0.54 % RH Edgetech RH-Cal QAI- T10 Thunder Scientific 2500 QAI-T08 Liquid-In-Glass Thermometers (-40 to 125) °C (125 to 300) °C 0.07 °C 0.07 °C Kaye IRTD temperature bath QAI-T02
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 18 of 19 Parameter/Equipment Range CMC 2, 7 (±) Comments Infrared Temperature3 (20 to 500) °C 0.55 % of reading + 0.074 °C Fluke 4181 QAI-T07 VIII. Time & Frequency Parameter/Equipment Range CMC 2, 7 (±) Comments Frequency – Measuring Equipment 3 10 mHz to 120 Hz 120 Hz to 1.2 kHz (1.2 to 12) kHz (12 to 120) kHz 120 kHz to 1.2 MHz (1.2 to 2) MHz 2.5 µHz/Hz + 10 mHz 2.5 µHz/Hz + 0.1 Hz 2.5 µHz/Hz + 1 Hz 2.5 µHz/Hz + 10 Hz 2.5 µHz/Hz + 0.1 kHz 2.5 µHz/Hz + 1 kHz Fluke 5520A GIDEP procedures OEM procedures Frequency – Measure 3 (1 to 100) Hz 100 Hz to 1 kHz (1 to 10) kHz (10 to 100) kHz 100 kHz to 1 MHz (1 to 10) MHz (10 to 100) MHz 100 MHz to 1 GHz (1 to 3) GHz 0.6 nHz 51 nHz 760 nHz 5.1 µHz 51 µHz 510 µHz 5.1 mHz 51 mHz 110 mHz Agilent 53132A GIDEP procedures OEM procedures Stopwatch / Period 3 Up to 100 s/d 0.051 s/d Helmut Klein 4500QAI-K01 Rotating Motion3 (9 to 90 000) rpm 0.0006 % of reading + 0.000 07 rpm Hewlett Packard 3325B GIDEP procedures OEM procedures Period Totalization 3 Up to 3600 s 11 µs/s + 8.2 ms Control Company 1051 GIDEP procedures OEM procedures ___________________ 1 This laboratory offers commercial calibration service and field calibration service.
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 19 of 19 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the length of the unit under test in inches. 5 The stated measured values are determined usin g the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
20ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

20 Hagerty Blvd, Suite 1, West Chester, PA, 19382, US

39.95974, -75.60446

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.