Precision Measurements
20 Hagerty Blvd, Suite 1, 19382, West Chester, PA, United States
Visit website- Scope lines
- 20
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 20 scope lines.
A2LA certificate 7185.01 · 20 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | Conductivity Solutions | - |
| 2 | QAI-MXX procedures; NIST Monograph 180; QAI-M18; QAI-M10 | - | See scope document |
| 3 | - | thermocoupleShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 3 of 19
III. Electrical – DC/Low Frequency
Parameter/Equipment Range CMC 2 (±) Comments
Temperature Calibration,
Indication, & Control
Equipment
3 Used with
Thermocouple
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.56 °C
0.19 °C
0.17 °C
0.19 °C
0.24 °C
0.31 °C
0.19 °C
0.17 °C
0.20 °C
0.26 °C
0.37 °C
0.21 °C
0.19 °C
0.29 °C
0.45 °C
0.45 °C
0.25 °C
0.22 °C
0.21 °C
0.31 °C
0.63 °C
0.39 °C
0.37 °C
0.45 °C
0.52 °C
0.40 °C
0.41 °C
0.51 °C
0.7 °C
0.27 °C
0.19 °C
0.17 °C
Fluke 5520A
electrical simulation of
thermocouple output;
GIDEP procedures
OEM procedures | See scope document |
| 4 | GIDEP procedures; OEM procedures | RTD | See scope document |
| 5 | - | RTDShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 5 of 19
Parameter/Equipment Range CMC 2, 5 (±) Comments
Temperature Calibration,
Indication & Control
Equipment used with
RTD
3 (cont)
Pt 3926, 100 Ω
Ni 385, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.06 °C
0.06 °C
0.07 °C
0.09 °C
0.09 °C
0.11 °C
0.07 °C
0.07 °C
0.12 °C
0.4 °C
Fluke 5520A,
electrical simulation of
RTD output;
GIDEP procedures,
OEM procedures
DC Voltage – Generate3
Up to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
20 µV/V + 1.8 µV
11 µV/V + 11 µV
11 µV/V + 23 µV
18 µV/V + 1.1 mV
18 µV/V + 4 mV
Fluke 5520A
QAI-EXX procedures
OEM procedures
DC Voltage – Measure3
Up to 200 mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1 to 10) kV
(10 to 40) kV
6.3 µV/V + 0.5 µV
3.7 µV/V + 0.3 µV
3.7 µV/V + 1 µV
5.8 µV/V + 10 µV
5.9 µV/V + 0.1 mV
0.4 mV/V + 40 mV
27 mV/V + 0.1 V
Fluke 8508A
QAI-EXX procedures
OEM procedures
Vitrek 4700 QAI-EXX
procedures OEM
procedures
Fluke 87V with 80K-
40 QAI-EXX
procedures OEM
procedures | See scope document |
| 6 | QAI-EXX procedures; OEM procedures | - | - |
| 7 | QAI-EXX procedures; OEM procedures | - | See scope document |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 8 of 19
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Inductance – Measure
3
(0.1 to 1) mH
(1 to 10) mH
(10 to 100) mH
(0.1 to 1) H
(1 to 10) H
(10 to 100) H
(0.1 to 1) kH
1 mH/H + 1.5 µH
1 mH/H + 15 µH
1 mH/H + 0.15 mH
1 mH/H + 1.4 mH
1 mH/H + 15 mH
1 mH/H + 0.17 H
5 mH/H + 1.9 H
Fluke PM6304
QAI-EXX
procedures OEM
procedures
Parameter/Range Frequency CMC 2, 5 (±) Comments
AC Voltage –Measure3
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
160 µV/V + 120 µV
130 µV/V + 21 µV
110 µV/V + 21 µV
80 µV/V + 21 µV
120 µV/V + 21 µV
230 µV/V + 41 µV
600 µV/V + 210 µV
3.1 mV/V + 2.1 mV
11 mV/V + 20 mV
160 µV/V + 1.3 mV
130 µV/V + 210 µV
97 µV/V + 210 µV
81 µV/V + 210 µV
120 µV/V + 210 µV
230 µV/V + 410 µV
580 µV/V + 2.1 mV
3.1 mV/V + 20 mV
11 mV/V + 0.2 V
160 µV/V + 13 mV
130 µV/V + 2.1 mV
97 µV/V + 2.1 mV
79 µV/V + 2.1 mV
120 µV/V + 2.1 mV
230 µV/V + 4.1 mV
580 µV/V + 21 mV
3.1 mV/V + 200 mV
11 mV/V + 2 V
Fluke 8508A
QAI-EXX
procedures OEM
procedures | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 9 of 19
Parameter/Range Frequency CMC 2, 5 (±) Comments
AC Voltage – Measure3
(cont)
(200 to 1000) V
(1 to 10) kV
(1 to 10) Hz
(10 to 40) Hz
40 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 mHz to 10 Hz
(10 to 65) Hz
(65 to 200) Hz
(200 to 450) Hz
1.6 mV/V + 71 mV
130 µV/V + 21 mV
170 µV/V + 21 mV
400 µV/V + 41 mV
670 µV/V + 0.2 V
1.4 mV/V + 0.2 V
1.4 mV/V + 0.2 V
1.4 mV/V + 0.2 V
4.7 mV/V + 0.2 V
Fluke 8508A
QAI-EXX
procedures OEM
procedures
Vitrek 4700
QAI-EXX
procedures OEM
procedures
AC Current – Measure
3
(20 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
510 µA/A + 20 nA
560 µA/A + 20 nA
750 µA/A + 20 nA
4.1 mA/A + 20 nA
340 µA/A + 0.2 µA
320 µA/A + 0.2 µA
720 µA/A + 0.2 µA
4.1 mA/A + 0.2 µA
340 µA/A + 2 µA
340 µA/A + 2 µA
730 µA/A + 2 µA
4.1 mA/A + 2 µA
340 µA/A + 20 µA
320 µA/A + 20 µA
640 µA/A + 20 µA
630 µA/A + 0.2 mA
940 µA/A + 0.2 mA
3.1 mA/A + 0.2 mA
830 µA/A + 2 mA
2.7 mA/A + 2 mA
Fluke 8508A
QAI-EXX
procedures OEM
procedures | ||
| 10 | QAI-EXX | AC Current | See scope document |
| 11 | QAI-EXX; GIDEP; OEM | - | - |
| 12 | QAI-EXX; GIDEP | AC Voltage | See scope document |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 13 of 19
IV. Electrical – RF/Microwave
Parameter/Range
Frequency CMC 2, 7 (±) Comments
RF Power – Generate3
4 nW to 100 mW
1 pW to 10 mW
100 µW to 100 mW
100 pW to 100 µW
(1 to 100) pW
100 pW to 100 mW
(1 to 100) pW
1 mHz to 100 kHz
100 kHz to 10 MHz
10 MHz to 2 GHz
(2 to 20) GHz
(2 to 20) GHz
(2 to 20) GHz
(20 to 31.8) GHz
(20 to 31.8) GHz
48 mW/W
150 mW/W
210 mW/W
210 mW/W
240 mW/W
260 mW/W
260 mW/W
590 mW/W
GIDEP procedures
OEM procedures
Hewlett Packard
3325B
Agilent E8257D
RF Power – Measure
3
10 µW to 1 W
100 pW to 10 µW
100 kHz to 26.5 GHz
10 MHz to 18 GHz
35 mW/W
46 mW/W
Hewlett Packard
8481D Agilent
E4416A N8482A
N8481A 8485A
RF Attenuation
3 –
Measure (TRFL)
100 µW to 1 mW
(10 to 100) µW
(1 to 10) µW
100 nW to 1 µW
(10 to 100) nW
(1 to 10) nW
100 pW to 1 nW
(10 to 100) pW
(1 to 10) pW
100 fW to 1 pW
100 µW to 1 mW
(10 to 100) µW
(1 to 10) µW
100 nW to 1 µW
(10 to 100) nW
(1 to 10) nW
100 pW to 1 nW
(10 to 100) pW
(1 to 10) pW
100 fW to 1 pW
2.5 MHz to 1.3 GHz
(200 Hz BW)
1.3 GHz to 26.5 GHz
(200 Hz BW)
12 mW/W
17 mW/W
21 mW/W
26 mW/W
40 mW/W
45 mW/W
50 mW/W
55 mW/W
70 mW/W
74 mW/W
12 mW
17 mW/W
21 mW/W
26 mW/W
40 mW/W
45 mW/W
50 mW/W
55 mW/W
120 mW/W
120 mW/W
Hewlett Packard
8902A GIDEP
procedures OEM
procedures | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 14 of 19
Parameter/Range
Frequency CMC 2, 7 (±) Comments
Phase Modulation –
Measure
150 kHz to 10 MHz
10 MHz to 1.3 GHz
(1.3 to 26.5) GHz
4 % of reading + 0.5 rad
3 % of reading + 0.5 rad
4 % of reading + 0.5 rad
Hewlett Packard
8902A GIDEP
procedures OEM
procedures
Amplitude Modulation –
Measure
Depths: 5 % to 99 %
Depths: to 99 %
Depths: 5 % to 99 %
Depths: to 99 %
Depths: 5 % to 99 %
Depths: to 99 %
150 kHz to 10 MHz
150 kHz to 10 MHz
10 MHz to 1.3 GHz
10 MHz to 1.3 GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
2.1 % of reading + 0.012
% AM
3.1 % of reading + 0.012
% AM
1.1 % of reading + 0.012
% AM
3.1 % of reading + 0.012
% AM
2.1 % of reading + 0.012
% AM
3.1 % of reading + 0.012
% AM
Hewlett Packard
8902A GIDEP
procedures OEM
procedures
Frequency Modulation –
Measure
Rate: 20 Hz to 200 kHz
Rate: 50 Hz to 100 kHz
Rate: 20 Hz to 200 kHz
Rate: 50 Hz to 100 kHz
250 kHz to 10 MHz
10 MHz to 1.3 GHz
10 MHz to 1.3 GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
20 mHz/Hz + 0.12 kHz
51 mHz/Hz + 20 Hz
11 mHz/Hz + 20 Hz
51 mHz/Hz + 20 Hz
11 mHz/Hz + 20 Hz
Hewlett Packard
8902A GIDEP
procedures OEM
procedures
V. Fluid Quantities
Parameter/Equipment Range CMC
2, 7 (±) Comments
Liquid Flow – Measuring
Equipment
3
Up to 80 gal/min
(80 to 800) gal/min
0.31 % of reading +
0.023 gal/min
0.19 % of reading +
0.016 gal/min
Micro Motion
DSH100H134P
DS300S155
GIDEP procedures
OEM procedures | ||
| 15 | - | Gas Flow; Scales & Balances; Load Cells/Force Gauges; Load CellsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 15 of 19
Parameter/Equipment Range CMC 2, 7 (±) Comments
Gas Flow – Measuring
Equipment
(1 to 10) SCCM
(10 to 100) SCCM
(100 to 1000) SCCM
(1 to 10) SLPM
(2.5 to 25) SLPM
(10 to 100) SLPM
(50 to 500) SLPM
0.4 % of reading +
0.000 58 SCCM
0.4 % of reading +
0.0058 SCCM
0.4 % of reading +
0.058 SCCM
0.4 % of reading +
0.58 SCCM
0.47 % of reading +
5.8 SCCM
0.5 % of reading + 5.8
SCCM
0.47 % of reading +
15 SCCM
Fluke MolBloc
system GIDEP
procedures OEM
procedures
VI. Mechanical
Parameter/Equipment Range CMC
2 (±) Comments
Scales & Balances3
(1 to 500) mg
1 g to 1 kg
(1 to 10) kg
(1 to 1000) lb
5.8 µg/g + 5.9 µg
2.1 µg/g + 64 µg
3.3 µg/g + 23 mg
0.012 % of reading
+ 0.2 lb
Class 1 Weights
QAI-A04
Class F Weights
NIST HB 44
Load Cells/Force Gauges
3
(1 to 600) lbf
0.0013 % of reading +
0.0066 lbf
Class F Weights
QAI-M11
Load Cells
3
(Tension, Compression)
(500 to 5000) N
(200 to 2) N
(20 to 1779) N
2.4 mN/N
5 mN/N
5 mN/N
Class F Weights
QAI-M11 | See scope document |
| 16 | OIML R111; GIDEP procedures | Weights; Pressure; Torque | - |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 17 of 19
Parameter/Equipment Range CMC 2, 7 (±) Comments
Torque – Measure3
(2 to 20) ozfꞏ in
(1 to 10) lbfꞏ in
(25 to 250) lbfꞏ in
(10 to 100) lbfꞏ ft
(25 to 250) lbfꞏ ft
0.63 % of reading +
0.001 ozfꞏ in
0.63 % of reading +
0.001 lbfꞏin
0.6 % of reading +
0.01 lbfꞏ in
0.63 % of reading +
0.0058 lbfꞏ ft
0.7 % of reading +
0.01 lbfꞏ ft
Mountz BMX20Z
BMX10i
BMX250i
BMX100F
BMX 250F QAI –M04
Torque – Measure
(10 to 100) lbfꞏ in
(100 to 1000) lbfꞏ ft
0.12 % of reading +
0.02 lbfꞏ in
0.12 % of reading +
0.2 lbfꞏ ft
AKO TDS QAI –M04
VII. Thermodynamics
Parameter/Equipment Range CMC
2, 7 (±) Comments
Temperature
measurement with RTD
3
-196 °C
-80 °C
(-40 to 125) °C
(125 to 300) °C
0.04 °C
0.04 °C
0.04 °C
0.04 °C
Kaye IRTD:
Liquid nitrogen
Dry ice
Temperature baths
QAI-T01
Relative Humidity3
(0 to 25) % RH
(25 to 75) % RH
(75 to 95) % RH
(10 to 95) % RH
1.3 % RH
0.77 % RH
1.3 % RH
0.54 % RH
Edgetech RH-Cal QAI-
T10
Thunder Scientific 2500
QAI-T08
Liquid-In-Glass
Thermometers
(-40 to 125) °C
(125 to 300) °C
0.07 °C
0.07 °C
Kaye IRTD temperature
bath QAI-T02 | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 18 of 19
Parameter/Equipment Range CMC 2, 7 (±) Comments
Infrared Temperature3
(20 to 500) °C
0.55 % of reading +
0.074 °C
Fluke 4181 QAI-T07
VIII. Time & Frequency
Parameter/Equipment Range CMC
2, 7 (±) Comments
Frequency – Measuring
Equipment
3
10 mHz to 120 Hz
120 Hz to 1.2 kHz
(1.2 to 12) kHz
(12 to 120) kHz
120 kHz to 1.2 MHz
(1.2 to 2) MHz
2.5 µHz/Hz + 10 mHz
2.5 µHz/Hz + 0.1 Hz
2.5 µHz/Hz + 1 Hz
2.5 µHz/Hz + 10 Hz
2.5 µHz/Hz + 0.1 kHz
2.5 µHz/Hz + 1 kHz
Fluke 5520A GIDEP
procedures OEM
procedures
Frequency – Measure
3
(1 to 100) Hz
100 Hz to 1 kHz
(1 to 10) kHz
(10 to 100) kHz
100 kHz to 1 MHz
(1 to 10) MHz
(10 to 100) MHz
100 MHz to 1 GHz
(1 to 3) GHz
0.6 nHz
51 nHz
760 nHz
5.1 µHz
51 µHz
510 µHz
5.1 mHz
51 mHz
110 mHz
Agilent 53132A
GIDEP procedures
OEM procedures
Stopwatch / Period
3
Up to 100 s/d
0.051 s/d
Helmut Klein
4500QAI-K01
Rotating Motion3
(9 to 90 000) rpm
0.0006 % of reading +
0.000 07 rpm
Hewlett Packard
3325B GIDEP
procedures OEM
procedures
Period Totalization
3
Up to 3600 s
11 µs/s + 8.2 ms
Control Company
1051 GIDEP
procedures OEM
procedures
___________________
1 This laboratory offers commercial calibration service and field calibration service. | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7185.01) Revised 05/11/2026 Page 19 of 19
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the length of the unit under test in inches.
5 The stated measured values are determined usin g the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 20 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Constellation PowerlabsCoatesville, PA · ~19 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Philadelphia, PALansdale, PA · ~42 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Laboratory TestingHatfield, PA · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Maxpro CorporationHorsham, PA · ~47 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Ellab, Inc.Doylestown, PA · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.