Canada

Eddyfi Canada

Quebec, Canada

Visit website
A2LA 2734.03ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
9
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 9 scope lines.

A2LA certificate 2734.03 · 9 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 1 of 8 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EDDYFI CANADA INC. 3425 Pierre-Ardouin St Quebec, QC, CANADA G1P 0B3 Ghislain Cournoyer, Quality Assurance Director Phone: 418 263 3686 CALIBRATION Valid To: August 31, 2027 Certificate Number: 2734.03 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 8: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments AC Resistance – Measure 3 (0 to 10) Ω 0.45 Ω Agilent 33250A, 33610 Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32 II. Time & Frequency (Ultrasound Instrumentation – Dynaray Series) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Low Cutoff High Cutoff (0.225 to 20) MHz None, HP1M, HP2M, HP5M, HP10M, LP2M < 2.2 % , All others < 0.90 % None, BP1-5M, HP1M, LP2M, LP5M, LP10M, LP15M < 6.5 % , All others < 1.9 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC ABUXE127A
0 to 10 Ω
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 2 of 8 Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Frequency Response: Bandwidth Center Linearity of Time Delays Gain Linearity Channel Gain Variation Linearity of Vertical Display Equivalent Input Noise (0.225 to 20) MHz Up to 50 µs (0 to 80) dB < 1.5 dB (Zetec) (0 to 28) dB rel. < 80 nV/√Hz None, HP1M, HP2M, HP10M, LP2M, LP15M < 2.5 % , All others < 1.0 % None, < 3.6 % , All others < 1.8 % 0.0063 % 0.47 dB 0.65 dB 0.53 % 7.0 nV/√Hz Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC ABUXE127A Transmitter – Ultrasound Instrumentation3 Voltage Rise Time Duration Linearity of Time Delays (25 to 250) V Up to 50 ns (25 to 1000) ns Up to 50 µs 1.8 % 0.78 ns 0.46 ns 0.070 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC ABUXE127A, 50 ohms/10W load
0.225 to 20 MHz
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 3 of 8 III. Time & Frequency (Ultrasound Instrumentation – Zircon-15, Zircon-18, Topaz16, Topaz32, Quartz) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response – Zircon-15, Zircon-18, Topaz32, Quartz: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center – Conventional Zircon-15 (0.50 to 15) MHz Zircon-18, Topaz32, Quartz (0.50 to 18) MHz < 0.70 % HP1M ≤ 3.2 % None, LP5M, LP10M, HP2M ≤ 2.4 % , All others ≤ 1.5 % < 0.80 % < 0.90 % < 0.70 % HP1M ≤ 8.0 % , None, HP2M ≤ 5.2 % LP5M, LP10M, BP1-5M, BP2-10M ≤ 1.9 % , All others ≤ 0.90 % < 0.90 % LP5M, HP1M ≤ 1.3 % , All others ≤ 1.0 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX)
0.5 to 18 MHz
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 4 of 8 Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Frequency Response – Topaz16: Phased Array Low Cutoff High Cutoff Bandwidth Center – Phased Array Conventional Low Cutoff High Cutoff Bandwidth Center (0.50 to 18) MHz < 0.80 % None, LP2M, LP5M, LP10M, HP1M, HP2M < 2.3 % , All others < 1.4 % LP2M < 1.1 % , All others < 0.90 % None, LP2M, LP5M < 1.4 % , All others < 1.0 % < 1.0 % None, HP1M, HP2M < 6.5 % LP2M, LP5M, LP10M, HP5M, BP1-5M, BP5- 18M < 3.0 % , All others < 1.7 % LP2M, BP5-18M, BP10- 18M < 1.6 % , All others < 1.0 % None, LP2M, BP5-18M < 1.9 % , All others < 1.0 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), 10059869 (IPEX)
0.5 to 18 MHz
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 5 of 8 Parameter/Equipment Range5 CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Linearity of Time Delays Gain Linearity Phased Array Conventional Channel Gain Variation Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise Up to 20 µs (0 to 70) dB (0 to 70) dB < 1.5 dB (Zetec) < 1.5 dB (Zetec) 28 dB rel. < 80 nV/√Hz 0.014 % 0.29 dB 0.27 dB 0.40 dB 0.38 dB 0.36 % 3.3 nV/√Hz Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage Phased Array Conventional Rise Time Phased Array Conventional Duration Phased Array Conventional Linearity of Time Delays (35 to75) V (50 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.0 % 2.6 % 0.57 ns 0.34 ns 0.51 ns 0.48 ns 0.051 % Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) 50 ohms/10W load
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 6 of 8 IV. Time & Frequency (Ultrasound Instrumentation – Topaz64, Emerald64) Parameter/Equipment Range CMC2, 4 (±) Comments Receiver – Ultrasound Instrumentation3 Frequency Response: Phased Array Low Cutoff High Cutoff Bandwidth Center Conventional Low Cutoff High Cutoff Bandwidth Center (0.50 to 18) MHz HP0.6M, LP2M, LP5M, LP10M, HP1M, BP1-5M: < ±6.5 % HP2M, BP1.75-7M, BP2-10M: < ±3.4 % All others: < ±1.7 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M:< ±2.5 % All others: < ±1.1 % HP0.6M, LP2M, LP5M, BP1- 5M, BP5-10M: < ±3.6 % All others: < ±1.9 % HP0.6M, LP2M, LP5M, LP10M, BP1-5M, BP1.75-7M: < ±4.3 % All others: < ±1.9 % LP2M, BP1-4M, BP1.125-4.5M, BP1.875-7.5M, BP5-20M, BP0.55-6M: < ±4.2 % All others: < ±3.0 % LP2M, BP1-4M, HP3M: < ±2.1 % All others: < ±1.2 % LP2M, BP1-4M, BP2-8M, BP5- 20M, HP10M: < ±3.1 % All others: < ±2.0 % LP2M, BP1-4M, BP1.125-4.5M, BP2-8M, HP10M, HP3M, BP0.55-6M: < ±3.7 % All others: < ±2.0 % Agilent 33250A, Tektronix TDS- 3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX)
0.5 to 18 MHz
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 7 of 8 Parameter/Equipment Range5 CMC2, 4, 5 (±) Comments Receiver – Ultrasound Instrumentation3 (cont) Linearity of Time Delays Gain Linearity Phased Array Conventional Channel Gain Variation Phased Array Conventional Linearity of Vertical Display Equivalent Input Noise Phased Array Conventional Up to 20 µs (0 to 70) dB (0 to 70) dB < 1.5 dB (Zetec) < 1.5 dB (Zetec) 28 dB rel. < 80 nV/√Hz 0.088 % 0.29 dB 0.27 dB 0.41 dB 0.37 dB 1.2 % 9.0 nV/√Hz 28 nV/√Hz Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC attenuator 10040260, ZETEC 10040371 (ZIF), ZETEC 10059869 (IPEX) Transmitter – Ultrasound Instrumentation3 Voltage Phased Array Conventional Rise Time Phased Array Conventional Duration Phased Array Conventional Linearity of Time Delays (10 to 75) V (20 to 200) V Up to 50 ns Up to 50 ns (25 to 500) ns (25 to 500) ns Up to 20 µs 2.2 % 2.7 % 0.57 ns 0.34 ns 0.49 ns 0.57 ns 0.056 % Agilent 33250A, Tektronix TDS-3032 (A, B, or C), MDO3032, MDO32, ZETEC 10040371 (ZIF) ZETEC 10059869 (IPEX) 50 ohms/10W load ____________________________________________
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2734.03) 05/23/2025 Page 8 of 8 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages represent percent of reading unless otherwise noted. 5 References to decibels (dB) refer to dB in voltage. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy.
9ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.