What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 57 standard numbers and the 5 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60811 series17
IEC 60811-202
IEC 60811-203
IEC 60811-401Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
IEC 60811-402
IEC 60811-404Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
IEC 60811-405
IEC 60811-409
IEC 60811-501Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
IEC 60811-502
IEC 60811-503
IEC 60811-504
IEC 60811-505
Show all 17
IEC 60811-506
IEC 60811-507
IEC 60811-508
IEC 60811-509
IEC 60811-605
IEC15
IEC 60076-1
IEC 60076-11
IEC 60227-3
IEC 60228
IEC 60229
IEC 60502-1
IEC 60502-2
IEC 60754-1
IEC 60754-2
IEC 60840
IEC 61034-2
IEC 61089
IEC 61439-1
IEC 61439-6
IEC 80811-201
BS11
BS 5467
BS 6346
BS 6387
BS 6469-99
BS 6622
BS 6724
BS 7835
BS 7846
BS 7870-4
BS 8491
BS 8573
ASTM4
ASTM D638Standard Test Method for Tensile Properties of Plastics
ASTM D648
ASTM D2152
ASTM D2444
IEC 60332 series4
IEC 60332-1-2Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-3-22
IEC 60332-3-23
IEC 60332-3-24
EN3
EN 50182
EN 50525-1
EN 50525-3-41
IEC 60331 series3
IEC 60331-1
IEC 60331-11
IEC 60331-21
BS 8491 (F30, F60, & F120); IEC 60331-21; IEC 60331-11; BS 6387 (C, W, & Z); BS 7846 (F2); BS EN IEC 60331-1; IEC 60502-2; IEC 60840; IEC 60811-501; BS EN 60811-401; IEC 60811-202; BS EN 80811-201; BS EN 60811-203; BS EN 60811-507; BS EN 60811-409; BS EN 60811-508; BS EN 60811-504; BS EN 60811-505; BS EN 60811-506; BS EN 60811-509; BS EN 60811-404; BS EN 60811-605; BS EN 60811-502; BS EN 60811-405; BS EN 60811-503
BS EN IEC 60811-402; IEC 60502-2; BS 6622; BS 7835; IEC 60840; BS 6469-99.1; BS EN 50525-1; BS EN 60754-2; BS EN 60754-1; IEC 60332-1-2; IEC 60332-3-22; IEC 60332-3-23; IEC 60332-3-24; IEC 61439-6; BS EN 61034-2
IEC 61439-1, Cl. 10.9.3; IEC 61439-6, Cl. 10.9.3; IEC 61439-6, Cl. 10.10; IEC 61439-6, Annex BB; IEC 61439-6, Annex CC; IEC 61439-6, Annex DD; IEC 60076-11, Cl. 14.2.2 // Part 1, Cl. 11.3; IEC 60076-11, Cl. 14.2.1 // Part 1, Cl. 11.2; IEC 60076-11, Cl. 14.2.5 // Part 3, Cl. 10; IEC 60076-11, Cl. 11.5 // Part 11; IEC 60076-11, Cl. 14.2.5 // Part 3, Cl. 10; IEC 60076-11, Cl. 14.2.6 // Part 3, Cl. 11.2; IEC 60076-11, Cl. 14.2.7 // Part 3; IEC 60076-11, Cl. 5.9, 10, and 14.3.2; IEC 60076-11, Cl. 14.4.2 // Part 10; BAHRA TBS Internal Procedure; IEC 60076-1, Cl. 11.6; IEC 60076-1, Cl. 10.6; IEC 60076-11, Cl. 14.3.1 // Part 3, Cl. 13
IEC 60502-2; IEC 60840; BS 6622; BS 7835; IEC 60228; IEC 60502-1; IEC 60227-3; BS EN 50525-3-41; BS 5467; BS 6346; BS 6724; BS 7846; BS 8573; IEC 60229; IEC 61089; EN 50182; HD 620 Section J; HD 605; BS 7870; IEC 61439-1, Cl. 10.5.2; IEC 61439-6, Cl. 10.5.2; IEC 61439-1, Cl. 10.9.2; IEC 61439-6, Cl. 10.9.2
IEC 61439-6, Clause 10.2.101; IEC 61439-1, Clause 10.4; IEC 61439-6, Clause 10.4; IEC 60502-2, Clause 18.2.4; BS 6622; BS 7870-4.11; BS 7835; IEC 60840, Clause 12.4.3; IEC 61439-6, Clause 10.13; IEC 61439-1, Clause 10.2.3.1
UL 651; NEMA TC 2; NEMA TC 6&8; NEMA TC 3; NEMA TC 9; ASTM D2444; ASTM D648; UL 651:2011; ASTM D2152; ASTM D638; IEC 61439-1, Clause 10.2.5; IEC 61439-6, Clause 10.2.5; IEC 61439-1, Clause 10.2.6; IEC 61439-6, Clause 10.2.6; IEC 61439-1, Clause 10.2.7; IEC 61439-6, Clause 10.2.7
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active4807.01
The scope document we hold says it is valid until 2028-09-30.
Accredited scope, certificate 4807.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | IEC 60502-2; IEC 60840; BS 6622; BS 7835; IEC 60228; IEC 60502-1; IEC 60227-3; BS EN 50525-3-41; BS 5467; BS 6346; BS 6724; BS 7846; BS 8573; IEC 60229; IEC 61089; EN 50182; HD 620 Section J; HD 605; BS 7870; IEC 61439-1, Cl. 10.5.2; IEC 61439-6, Cl. 10.5.2; IEC 61439-1, Cl. 10.9.2; IEC 61439-6, Cl. 10.9.2 | Power Cables and Wires, Enclosures, Conduits & Busways | - |
| 2 | IEC 61439-1, Cl. 10.9.3; IEC 61439-6, Cl. 10.9.3; IEC 61439-6, Cl. 10.10; IEC 61439-6, Annex BB; IEC 61439-6, Annex CC; IEC 61439-6, Annex DD; IEC 60076-11, Cl. 14.2.2 // Part 1, Cl. 11.3; IEC 60076-11, Cl. 14.2.1 // Part 1, Cl. 11.2; IEC 60076-11, Cl. 14.2.5 // Part 3, Cl. 10; IEC 60076-11, Cl. 11.5 // Part 11; IEC 60076-11, Cl. 14.2.5 // Part 3, Cl. 10; IEC 60076-11, Cl. 14.2.6 // Part 3, Cl. 11.2; IEC 60076-11, Cl. 14.2.7 // Part 3; IEC 60076-11, Cl. 5.9, 10, and 14.3.2; IEC 60076-11, Cl. 14.4.2 // Part 10; BAHRA TBS Internal Procedure; IEC 60076-1, Cl. 11.6; IEC 60076-1, Cl. 10.6; IEC 60076-11, Cl. 14.3.1 // Part 3, Cl. 13 | Transformers | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active4807.02
The scope document we hold says it is valid until 2028-09-30.
Accredited scope, certificate 4807.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | BS EN IEC 60811-402; IEC 60502-2; BS 6622; BS 7835; IEC 60840; BS 6469-99.1; BS EN 50525-1; BS EN 60754-2; BS EN 60754-1; IEC 60332-1-2; IEC 60332-3-22; IEC 60332-3-23; IEC 60332-3-24; IEC 61439-6; BS EN 61034-2 | Power Cables and Wires, Enclosures, Conduits, & Busways | - |
| 2 | BS 8491 (F30, F60, & F120); IEC 60331-21; IEC 60331-11; BS 6387 (C, W, & Z); BS 7846 (F2); BS EN IEC 60331-1; IEC 60502-2; IEC 60840; IEC 60811-501; BS EN 60811-401; IEC 60811-202; BS EN 80811-201; BS EN 60811-203; BS EN 60811-507; BS EN 60811-409; BS EN 60811-508; BS EN 60811-504; BS EN 60811-505; BS EN 60811-506; BS EN 60811-509; BS EN 60811-404; BS EN 60811-605; BS EN 60811-502; BS EN 60811-405; BS EN 60811-503 | Insulation; Sheaths; Metal Sheath; Polyethylene Compounds | - |
| 3 | UL 651; NEMA TC 2; NEMA TC 6&8; NEMA TC 3; NEMA TC 9; ASTM D2444; ASTM D648; UL 651:2011; ASTM D2152; ASTM D638; IEC 61439-1, Clause 10.2.5; IEC 61439-6, Clause 10.2.5; IEC 61439-1, Clause 10.2.6; IEC 61439-6, Clause 10.2.6; IEC 61439-1, Clause 10.2.7; IEC 61439-6, Clause 10.2.7 | - | - |
| 4 | IEC 61439-6, Clause 10.2.101; IEC 61439-1, Clause 10.4; IEC 61439-6, Clause 10.4; IEC 60502-2, Clause 18.2.4; BS 6622; BS 7870-4.11; BS 7835; IEC 60840, Clause 12.4.3; IEC 61439-6, Clause 10.13; IEC 61439-1, Clause 10.2.3.1 | - | - |
| 5 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .