SdM Pirometria Aerospacial S de RL de CV

Josefina #6120, Colonia Lomas del Rey, Juárez Chihuahua, 32680, Mexico, Juárez Chihuahua, Mexico

Visit website
A2LA 3181.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
8
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 8 scope lines.

A2LA certificate 3181.01 · 8 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 1 of 7 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SDM PIROMETRIA AEROSPACIAL S DE RL DE CV Josefina #6120 Colonia Lomas del Rey CP 32651 Cuidad Juarez, Chihuahua, MEXICO 32680 Emma Torres Phone: +52 656 541 2937 CALIBRATION Valid To: June 30, 2027 Certificate Number: 3181.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Dimensional Parameter/Equipment Range CMC2 (±) Comments Calipers3 Up to 12 in Up to 24 in 0.000 93 in 0.0018 in Gage blocks Optical Comparators3 – X, Y Axis Length Magnification Up to 12 in Up to 50x 0.000 83 in 0.0016 in Glass optical scale Magnification check scale Surface Plate3 – Repeat Readings Width or Length: Up to 48 in 42 µin Repeat-O-Meter
to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 2 of 7 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage3 – Generate (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (100 to 1020) V 2.5 µV 0.02 mV 0.3 mV 4.5 mV 5.7 mV Fluke 5500A-SC600 DC Voltage3 – Measure High Voltage (0 to 1) V (1 to 10) V (10 to 100) V 1000 V (0 to 1) kV (1 to 25) kV (25 to 40) kV 6.9 µV 0.34 mV 1.2 mV 8.1 mV 0.2 kV 0.5 kV 1.6 kV Agilent 3458A Fluke 80K-40, DMM DC Current3 – Generate (0 to 3.3) mA (3.3 to 33) mA (33 to 330) mA 330 mA to 2.2 A (2.2 to 11) A 0.047 µA 0.69 µA 11 µA 0.44 mA 1.1 mA Fluke 5500A-SC600 DC Current3 – Measure (10 to <100) µA (0.10 to <1) mA (1 to <10) mA (10 to <100) mA (0.1 to 1.0) A 0.0023 μA 0.000 029 mA 0.0002 mA 0.0026 mA 0.000 14 A Agilent 3458A Resistance3 – Measure 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 0.35 mΩ 4 mΩ 12 mΩ 170 mΩ 1.6 Ω 19 Ω 1.2 kΩ Agilent 3458A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 3 of 7 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate 0.001 Ω 0.010 Ω 0.100 Ω 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 0.07 mΩ 0.072 mΩ 0.077 mΩ 0.21 mΩ 2.2 mΩ 2.2 mΩ 0.1 Ω 0.82 Ω 1.5 Ω 0.16 Ω 2.5k Ω 0.051 MΩ Fluke 5500A-SC600 Decade resistors (33K8-4-1198-1) Capacitance – Generate (50 to 1000 Hz) (50 to 400 Hz) (0.33 to 0.4999) nF (0.5 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.99) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (330 to 1.1) mF 0.003 nF 0.0024 nF 0.018 nF 0.066 nF 0.026 nF 0.068 nF 0.2 nF 0.0014 µF 0.0041 µF 0.014 µF 0.046 µF 0.14 µF 1.3 µF 0.015 mF Fluke 5500A-SC600 Electrical Calibration of Temperature Indicators – Thermocouples Type J (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.28 °C 0.17 °C 0.15 °C 0.18 °C 0.25 °C Fluke 5500A-SC600
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 4 of 7 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz 45 Hz to 1 kHz (1 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 8) kHz 14 µV 14 µV 17 µV 25 µV 0.043 mV 0.03 mV 0.022 mV 0.013 mV 0.012 mV 0.037 mV 0.063 mV 0.35 mV 0.13 mV 0.16 mV 0.2 mV 0.41 mV 0.58 mV 1.4 mV 3.8 mV 4.1 mV 0.037 V 0.03 mV 0.057 V 0.072 V 0.042 V Fluke 5500A-SC600 AC Voltage3 – Measure 10 mV 100 mV to 10 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 4 µV 3.9 µV 3.3 µV 9.8 µV 0.02 mV 0.23 mV 0.71 mV 0.66 mV 0.52 mV 0.9 mV 1.9 mV Agilent 3458A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 5 of 7 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (cont) 100 V 700 V High Voltage 40 Hz to 1 kHz (1 to 20) kHz 40 Hz to 1 kHz (0 to 1) kV @ 60 Hz 7.1 mV 6.9 mV 0.044 V 2.4 kV Agilent 3458A Fluke 80K-40, DMM AC Current3 – Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA 330 mA to 2.2 A (2.2 to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (10 to 45) Hz 45 Hz to 1 kHz (45 to 65) Hz 0.32 µA 0.31 µA 0.32 µA 0.32 µA 0.2 µA 0.18 µA 0.26 µA 0.27 µA 0.38 µA 3.1 µA 4.4 µA 4.3 µA 3.6 µA 1.9 µA 0.12 mA 0.27 µA 0.64 µA 0.37 µA 1.8 mA 1.3 mA 8.4 mA Fluke 5500A-SC600
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 6 of 7 Parameter/Range Frequency CMC2, 5 (±) Comments Oscilloscopes3 – Square Wave Signal – 50 Ω at 1 kHz 1 MΩ at 1 kHz Leveled Sine Wave – Amplitude (50 kHz ref) Flatness (50 kHz ref) Time Markers Source and Period Into a 50 Ω Load Rise Time 1 mV pk-pk to 6.6 Vpk-pk 1 mV pk-pk to 130 Vpk-pk 50 kHz to 600 MHz 50 kHz to 600 MHz 5 s to 2 ns <300 ps 0.0032Vpk-pk + 100 µV 0.0056Vpk-pk + 100 µV 0.22V + 0.30 µV 1.6 % + 0.10 µV 0.5 % 150 ps Fluke 5500A with SC600 III. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Pressure Gages3 – Pneumatic Hydraulic Up to 500 psig (2000 to 10 000) psig 0.3 psig 24 psig Fluke 700P07 pressure module SI Ruska DGT-2K high pressure gage Scales3 (0.5 to 600) lb 0.58R + 0.019 % Class F weights
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3181.01) 09/10/2025 Page 7 of 7 IV. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Environmental Chamber3 (Including: Freezer, Oven, Incubator, Refrigerator) – Temperature Mapping, TUS & SAT Humidity Measure (55 to 555) °C (20 to 80) % RH 1.8 °C 2.6 % RH Agilent 3497A data acquisition & K type thermocouples Vaisala HMC 20 ____________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 In the statement of CMC, R is the resolution of device under calibration. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
55 to 555 °C
8

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited SDM PIROMETRIA AEROSPACIAL S DE RL DE CV Cuidad Juarez, Chihuahua, MEXICO for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 10th day of September 2025. _______________________ Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3181.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.