Stellantis Europe SpA - EMC
Via Fausto Coppi 1, 10043, Orbassano, Italy
- Accredited standards
- 10
- ACCREDIA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
IEC 55036
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11451-2Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Off-vehicle radiation sources
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
UNECE 116R00/08 (2021); UNECE 116R00/09 (2022); CISPR 25:2002/Cor 1:2004; CISPR 25:2008/Cor 1:2009; CISPR 25:2016/Cor 1:2017; CISPR 25:2021; EN 55025:2008; EN 55025:2017/AC1:2017; EN IEC 55025:2022; UNECE 10R03/00 (2008); UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/02 (2022); UNECE 10R06/03 (2024); ISO 7637-2:2004/Amd1:2008; ISO 7637-2:2011; ISO 11452-4:2005/Cor.1:2009; ISO 11452-4:2011; ISO 11452-4:2020; ISO 11452-2:2004; ISO 11452-2:2019; ISO 11452-8:2007; ISO 11452-8:2015; ISO 7637-3:2007; ISO 7637-3:2016; ISO 10605:2008/EC1:2010/A1:2014; ISO 10605:2023
GB/T 18387:2017; CEI EN IEC 55036:2021; CISPR 36:2020; EN IEC 55036:2020; ISO 16750-2:2006; ISO 16750-2:2010; ISO 16750-2:2012; ISO 16750-2:2023; GB/T 19951:2019; GB/T 37130:2018; ICES-002 Issue 7:2020; UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/03 (2024); UNECE 10R03/00 (2008); UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/02 (2022); UNECE 10R06/03 (2024); GB 34660:2017; CISPR 12:2001; CISPR 12:2007/Amd 1:2009; GB 14023:2011; GB 14023:2022; UNI CEI EN ISO/IEC 17025:2018
ISO 11451-2:2001; ISO 11451-2:2005; ISO 11451-2:2015; UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/03 (2024); UNI CEI EN ISO/IEC 17025:2018
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
4 lines
ISO/IEC 17025
Active00103
Accredited scope, certificate 00103
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNECE 116R00/08 (2021); UNECE 116R00/09 (2022); CISPR 25:2002/Cor 1:2004; CISPR 25:2008/Cor 1:2009; CISPR 25:2016/Cor 1:2017; CISPR 25:2021; EN 55025:2008; EN 55025:2017/AC1:2017; EN IEC 55025:2022; UNECE 10R03/00 (2008); UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/02 (2022); UNECE 10R06/03 (2024); ISO 7637-2:2004/Amd1:2008; ISO 7637-2:2011; ISO 11452-4:2005/Cor.1:2009; ISO 11452-4:2011; ISO 11452-4:2020; ISO 11452-2:2004; ISO 11452-2:2019; ISO 11452-8:2007; ISO 11452-8:2015; ISO 7637-3:2007; ISO 7637-3:2016; ISO 10605:2008/EC1:2010/A1:2014; ISO 10605:2023 | Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular; Veicoli/Vehicles | See scope document |
| 2 | GB/T 18387:2017; CEI EN IEC 55036:2021; CISPR 36:2020; EN IEC 55036:2020; ISO 16750-2:2006; ISO 16750-2:2010; ISO 16750-2:2012; ISO 16750-2:2023; GB/T 19951:2019; GB/T 37130:2018; ICES-002 Issue 7:2020; UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/03 (2024); UNECE 10R03/00 (2008); UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/02 (2022); UNECE 10R06/03 (2024); GB 34660:2017; CISPR 12:2001; CISPR 12:2007/Amd 1:2009; GB 14023:2011; GB 14023:2022; UNI CEI EN ISO/IEC 17025:2018 | Veicoli stradali elettrici e ibridi/Electric and hybrid electric road vehicles; Veicoli stradali/Road vehicles; Veicoli/Vehicles | - |
| 3 | ISO 11451-2:2001; ISO 11451-2:2005; ISO 11451-2:2015; UNECE 10R04/01 (2012); UNECE 10R05/00 (2014); UNECE 10R05/01 (2016); UNECE 10R06/03 (2024); UNI CEI EN ISO/IEC 17025:2018 | - | 20 to 6000 MHz |
| 4 | - | Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular; Veicoli/VehiclesShow page textExtracted from the scope document; tables may not line up. View scope for the original. Stellantis Europe SpA - EMC Laboratories
UNI CEI EN ISO/IEC 17025:2018
Allegato al certificato di accreditamento n. 00103 rev. 11 del 19/12/2025
Via Fausto Coppi 1
10043 Orbassano TO
Revisione: 42
Sede A
Data: 19/12/2025
pag. 4 di 4
ELENCO Prove Accreditate - Con Campo Flessibile
Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular
Denominazione della prova / Campi di prova
Metodo di prova
Tecnica di prova
O&I
Emissioni elettromagnetiche condotte/Conducted emission
Emissioni transitorie/Transient emission
Isolamento elettrico/Electrical insulation
Prove di immunità agli impulsi/Immunity tests to pulses
Prove di immunità ai campi magnetici/Magnetic fields immunity test
Prove di immunità ai transienti elettrici attraverso accoppiamento capacitivo e
induttivo su linee diverse da quelle di alimentazione/Electrical transient
transmission by capacitive and inductive coupling via lines other than supply
lines immunity test
Variazione della tensione di alimentazione e condizione di guasto/Supply voltage
variation and fault condition
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
_
_
_
_
_
_
_
Dispositivi elettrici ed elettronici per applicazione veicolistiche/Electrical and electronic applications for vehicular, Veicoli/Vehicles
Denominazione della prova / Campi di prova
Metodo di prova
Tecnica di prova
O&I
Emissioni elettromagnetiche irradiate/Radiated emission
Immunità ai campi elettromagnetici/Immunity to electromagnetic fields
Prove di immunità a scariche di elettricità statica/Electrostatic discharge
immunity test
Veicoli/Vehicles
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
_
_
_
Denominazione della prova / Campi di prova
Metodo di prova
Tecnica di prova
O&I
Misura di emissioni di disturbi irradiati/Measurement of radiated emission
Vedere elenco dei dettagli delle prove
flessibili/See list of flexible scope
details
_
Legenda/Note
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.