Registers refreshed 2026-11-20.See refresh dates
China

Shenzhen HongBiao Certification& Testing Co.,

Guangdong, Shenzhen, China

Visit website
A2LA 6765.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
14
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 14 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 13identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55013. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national

National versions in the same scope

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national

National versions in the same scope

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ICES-001Industrial, Scientific and Medical (ISM) Equipment

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

6765.01

The scope document we hold says it is valid until 2026-11-30.

View scope

Accredited scope, certificate 6765.01

LineMethodMatrixRange
147 CFR, FCC Parts 15 B (using ANSI C63.4:2014); FCC Part 18 (using FCC MP-5-1986); ICES-001; ICES-003; ICES-005; ICES-006; EN 55011; EN 55013; EN 55014-1; EN 55015; EN 55032; BS EN 55011; BS EN IEC 55014-1; BS EN IEC 55015; BS EN 55032; CISPR 11, AS/NZS CISPR 11; CISPR 13, AS/NZS CISPR 13; CISPR 14-1, AS/NZS CISPR 14.1; CISPR 15, AS/NZS CISPR 15; CISPR 32, AS/NZS CISPR 32; HKTA 1007; VCCI V-3 (up to 6 GHz); J 55013; J 55014-1; J 55032; EN 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN IEC 61000-4-3:2020; BS EN IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6-to 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6765.01) 10/28/2024 Page 2 of 3 Test Technology: Test Methods1,2: Power Frequency Magnetic Field EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8 Generic and Product Family Standards IEC 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-2; BS EN IEC 61000-6-2; IEC 61000-6-3; BS EN 61000-6-3:2021; IEC 61000-6-4; BS EN IEC 61000-6-4; IEC 61547; IEC 61326-1; EN 61000-6-1; EN 61000-6-2; EN 61000-6-3; BS EN IEC 61000-6-3; EN 61000-6-4; EN 55024; CISPR 24; EN 55035; BS EN 55035; BS EN IEC 55035; EN IEC 55014-2; BS EN IEC 55014-2; EN 61547; BS EN 61547; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-7; EN 301 489-8; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-23; EN 301 489-24; EN 301 489-34; EN 301 489-50; EN 301 489-52 Radio Communications Intentional and Unintentional Radiators (up to 40 GHz) 47 CFR Part 15 B (using ANSI C63.4:2014); 47 CFR Parts 15 C, E (using ANSI C63.10:2020); 47 CFR Parts 22, 24, 25, and 27 (using ANSI/TIA-603-E and TIA 102.CAAA-E); ANSI C63.26:2015); RSS-GEN; RSS-102; RSS-102.NS. MEAS; SPR-002 (issue 2); RSS-112; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-139; RSS-195; RSS-197; RSS-199; RSS-210; RSS-213; RSS-216; RSS-247; EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300 220-4; EN 300 440; EN 300 330; EN 303 345-1; EN 303 345-2; EN 303 345-3; EN 303 345-4; EN 303 413; EN 303 417; EN 301 511; EN 301 908-1; EN 301 908-2; EN 301 908-13; EN 62311; EN 62479; ARIB T-33; ARIB T-66; ARIB T-71; Article 2, Paragraph 1 of the Ordinance: Item 19; Item 19-2; Item 19-2-2; Item 19-2-3; Item 19-3; Item 19-3-2; Item 11-3; Item 11-7; Item 11-19 QI Tests Qi Specification Power Transmitter Compliance Tests Version 2.0.1 Qi Specification MPP Power Transmitter Compliance Tests Version 2.0.1 Qi Specification Power Transmitter Compliance Tests Version 1.3.3
3ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI/TIA-603-E-2016; TIA-102.CAAA-E-2016-to 40000 MHz
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited SHENZHEN HONGBIAO CERTIFICATION& TESTING CO., LTD Shenzhen, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of October 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6765.01 Valid to November 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Guangdong, Shenzhen, CN

22.55003, 113.88086

Open in Maps

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.