TTL Laboratories - A Division of R.I. Analytical
41 Illinois Avenue, 02888-3007, Warwick, RI, United States
Visit website- Accredited standards
- 12
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
EPA9
EPA 3050
EPA 3051
EPA 3540
EPA 3546
EPA 6010Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)
EPA 6020Inductively Coupled Plasma - Mass Spectrometry
EPA 7470
EPA 7471
EPA 8270Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS)
ASTM3
ASTM D6661
ASTM E1645
ASTM F963Exclusion
Limits written next to it
4.2 (ASTM F963-23) Flammability (except A6)
4.6 (ASTM F963-23) Small Objects (Except
4.7 (ASTM F963-23) Accessible Edges (Except
4.9 (ASTM F963-23) Accessible Points (Except
4.21 (ASTM F963-23) Projectile Toys (Except for
CPSC-CH-C1001-09.4; EPA 3540C; EPA 3546; EPA 8270D; CPSC-CH-E1004-11; CPSC-CH-E1002-08.2; CPSC-CH-E1001-08.2; CPSC-CH-E1003-09; TTL 16 Including NIOSH 9100 (Mod.); TTL 16 Including ASTM D6661-17 (Mod.); ASTM F963-23; ASTM E1645-01; EPA 3050B; EPA 3051A; EPA 7470A; EPA 6010C; EPA 6020B; EPA 7471B
EPA 3050B; EPA 6010C; EPA 6020B
ASTM F963-23
16 CFR 1501; 16 CFR 1500.50 -53; ASTM F963-23
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active2815.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2815.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CPSC-CH-C1001-09.4; EPA 3540C; EPA 3546; EPA 8270D; CPSC-CH-E1004-11; CPSC-CH-E1002-08.2; CPSC-CH-E1001-08.2; CPSC-CH-E1003-09; TTL 16 Including NIOSH 9100 (Mod.); TTL 16 Including ASTM D6661-17 (Mod.); ASTM F963-23; ASTM E1645-01; EPA 3050B; EPA 3051A; EPA 7470A; EPA 6010C; EPA 6020B; EPA 7471B | children's products; Child Care Items; Toys; Children's Metal Jewelry; Non-Metal Children's Products; Children's Metal Products; Paint and Other Similar Surface Coatings; Consumer Products | - |
| 2 | EPA 3050B; EPA 6010C; EPA 6020B | Dust; Paint; Soil | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active2815.02
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2815.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM F963-23 | toys and children’s products | - |
| 2 | 16 CFR 1501; 16 CFR 1500.50 -53; ASTM F963-23 | Toys | - |
| 3 | ASTM F963-23 | - | - |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
TTL LABORATORIES – A DIVISION OF R.I. ANALYTICAL LABORATORIES, INC.
Warwick, RI
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 16th day of May 16.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 2815.02
Valid to March 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.