Registers refreshed 2026-11-08.See refresh dates
South Korea

Global CS Center of Samsung Electronics Co

(Maetan Dong) 129, Samsung-ro, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do 16677, Korea, South Korea

Visit website
UKAS 4290ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
47
UKAS certificate
1
Sites in our directory
2
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 47 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI16
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-7
ETSI EN 301 489-8
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-23
ETSI EN 301 489-24
ETSI EN 301 489-26
ETSI EN 301 489-33
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI EN 303 340
ETSI EN 303 372-2
ETSI EN 303 386
ETSI EN 303 446-1
IEC 61000 series14
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments

Limits written next to it

this Schedule, but limited to EN IEC 61000-6-1:2019

Written next to it on line 10 of UKAS certificate 4290.

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-8
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementExclusion+2 national

Limits written next to it

IT Equipment excluding discontinuous EN 55011:2009+A1:2010

Exclusion. Written next to it on line 3 of UKAS certificate 4290.

National versions in the same scope

AS CISPR 11national version with changes

AS/NZS CISPR 11national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 13identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55013. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national

National versions in the same scope

AS CISPR 14.1national version with changes

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says EN 55014-2, IEC 55014-2. Probably the same standard; not checked against the EN document.

CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 22identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55022. Probably the same standard; not checked against the EN document.

CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement

Certificate says EN 55024. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national

National versions in the same scope

AS/NZS CISPR 32identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

IEC4
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and testsSome materials

Limits written next to it

Limited to Small Portable EN 60601-1-2:2015 R5

Some materials. Written next to it on line 11 of UKAS certificate 4290.

IEC 60601-2-47
IEC 61204-3
IEC 61960-3Some clauses

Limits written next to it

2.22 Discharge Performance Clause 7.3.2, IEC 61960-3:2017 R4

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

2.23 Charge (Capacity) Clause 7.4, IEC 61960-3:2017 R4

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

2.24 Charge (capacity) Clause 7.5, IEC 61960-3:2017 R4

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

Clause 7.3.1, IEC 61960-3:2017

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

Clause 7.3.3, IEC 61960-3:2017

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

2.24 Endurance in cycles Clause 7.6, IEC 61960-3:2017 R4

Some clauses. Written next to it on line 16 of UKAS certificate 4290.

2.25 Internal resistance Clause 7.7, IEC 61960-3:2017

Some clauses. Written next to it on line 16 of UKAS certificate 4290.

IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: ColdSome clauses

Limits written next to it

Clause 6, IEC 60068-2-1

Some clauses. Written next to it on line 16 of UKAS certificate 4290.

IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heatSome clauses

Limits written next to it

Clause 6, IEC 60068-2-2

Some clauses. Written next to it on line 16 of UKAS certificate 4290.

IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimensSome clauses

Limits written next to it

Clause 5, IEC 60068-2-31

Some clauses. Written next to it on line 15 of UKAS certificate 4290.

Other standards2
BS 4002
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems

Read from the scope as published by UKAS. Register refreshed 2026-11-06.

Scope as published by UKAS

21 lines
UKAS

ISO/IEC 17025

Active

4290

View scope

Other Locations

1 other site in this organization

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.