Registers refreshed 2026-11-20.See refresh dates
Malaysia

Motorola Penang Product Quality And Reliability Engineering

Motorola Solutions Malaysia Sdn Bhd (Innoplex), Plot 2A, Medan Bayan Lepas, Mukim 12 S.W.D, 11900, Penang, Malaysia, Penang, Malaysia

Visit website
A2LA 4252.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
22
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 22 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series12
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-29
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-31Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-32
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
IEC 60068-2-56
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

ETSI5
ETSI EN 300 019-1-1
ETSI EN 300 019-1-2
ETSI EN 300 019-1-3
ETSI EN 300 019-1-5
ETSI EN 300 019-1-7
IEC4
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60571
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
Other standards1
EN 50155Railway applications - Rolling stock - Electronic equipment

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

4252.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 4252.01

LineMethodMatrixRange
1IEC 60529 IPX4; IEC 60529 IPX5; IEC 60529 IPX6; IEC 60529 IPX7; IEC 60529 IPX8; GB 4208; IEC 60529 IP5X; IEC 60529 IP6X; GB 4208; MIL-STD-810 Method 501; EN 50155; IEC 60945 Section 8.2.1 and 8.2.2; IEC 60068-2-2; EN 300 019-1-7; EN 300 019-1-5; GJB 150.3; IEC 60571; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; MIL-STD-810 Method 502; EN 50155; IEC 60945 Section 8.4.1 and 8.4.2; IEC 60068-2-1; EN 300 019-1-7; EN 300 019-1-5; GJB 150.4; IEC 60571; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; MIL-STD-810 Method 503; IEC 60068-2-14; IEC 60945 Section 8.5; EN 300 019-1-7; EN 300 019-1-5; GJB 150.5; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; MIL-STD-810 Method 506; IEC 60945 Section 8.8; GJB 150.8; NEMA 250 Section 5.7; MIL-STD-810 Method 507; EN 50155; IEC 60945 Section 8.3; IEC 60068-2-30; IEC 60068-2-56; EN 300 019-1-7; EN 300 019-1-5; GJB 150.9; IEC 60571; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; MIL-STD-810 Method 509; EN 50155; IEC 60945 Section 8.12; IEC 60068-2-52; GJB 150.11; IEC 60571; NEMA 250 Section 5.9.1 and 5.10; ISO/IEC 17025:2017--57 to 95 °C
2MIL-STD-810 Method 512; IEC 60945 Section 8.9.3; MIL-STD-810 Method 514; EN 50155; IEC 60945 Section 8.7; IEC 61373; IEC 60068-2-6; IEC 60068-2-64; EN 300 019-1-7; EN 300 019-1-5; GJB 150.16; IEC 60571; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; NEMA TS 2 Section 2.2.8; MIL-STD-810 Method 516; EN 50155; IEC 60068-2-27; IEC 60068-2-29 (1987); IEC 60068-2-31; IEC 60068-2-32 (1990); IEC 60945 Section 8.6; IEC 61373; EN 300 019-1-7; EN300 019-1-5; GJB 150.18; IEC 60571; EN 300 019-1-1; EN 300 019-1-2; EN 300 019-1-3; NEMA TS 2 Section 2.2.9; MIL-STD-810 Method 504-to 100 g
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited MOTOROLA PENANG PRODUCT QUALITY AND RELIABILITY ENGINEERING LABORATORY Penang, Malaysia for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 2nd day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 4252.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Motorola Solutions Malaysia Sdn Bhd (Innoplex), Plot 2A, Medan Bayan Lepas, Mukim 12 S.W.D, 11900, Penang, Malaysia, Penang, MY

5.40650, 100.25591

Open in Maps

Accreditation data refreshed from the A2LA register on .