Sporton International (USA)
1175 Montague Expressway, 95035, Milpitas, CA, United States
Visit website- Accredited standards
- 49
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 49 standard numbers and the 27 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI20
ETSI EN 300 220-1
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440-1
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-24
ETSI EN 301 893
ETSI EN 302 208
ETSI EN 302 567
ETSI EN 303 446-1
Show all 20
ETSI EN 303 446-2
ETSI EN 305 550-1
ETSI TS 136 101
ETSI TS 136 521-1
ETSI TS 138 101-1
ETSI TS 138 101-3
ETSI TS 138 521-1
ETSI TS 138 521-3
IEC 61000 series14
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR5
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentExclusion
Limits written next to it
BS EN 55015 (excluding 9kHz-30MHz)
IEC/CISPR 15, EN 55015 (excluding 9kHz-30MHz)
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC4
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 62232
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
FCC MP-5:1986
FCC PART 15Radio Frequency Devices
Korea - Radio Regulations on Radio Equipment (Ordinance of MSIT NO. 86, Jan 4, 2022); Unlicensed Radio Equipment Established Without Notice (MSIT Public Notification 2022-20, May 10, 2022); Technical Requirements for Radio Equipment for Telecommunication Services (RRA Public Notification 2022-15, July 29, 2022); Technical Requirements of the Other Service Radio Equipment for Simple radio station, Space station and Earth station (RRA Public Notification 2021-35, Dec 28, 2021); Technical Requirements of Radio Wave Application (RRA Public Notification 2016-20, Sep 27, 2016); KSX3123, KSX3142, KSX3270, KSX3271; Vietnam - Radio QCVN 54:2020/BTTTT; QCVN 55:2011/BTTTT; QCVN 55:2023/BTTTT; QCVN 65:2013/BTTTT; QCVN 65:2021/BTTTT QCVN 117:2020/BTTTT QCVN 117:2023/BTTTT QCVN 127:2021/BTTTT QCVN 129:2021/BTTTT; Singapore- Radio and EMC IMDA TS SRD; IMDA TS CMT; ETSI EN 300 330; ETSI EN 300 220-1; ETSI EN 300 440-1; ETSI EN 302 208; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 305 550-1; ETSI EN 302 567; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-17; ETSI EN 301 489-24; ANSI C63.10-2013; ANSI C63.10-2020; FCC Part 15 Subpart C, FCC Part 15 Subpart E, FCC Part 95 Subpart M, FCC Part 15 Subpart B; IEC CISPR 32, IEC CISPR 24; Hong Kong- Radio HKCA 1001; HKCA 1002; HKCA 1003; HKCA 1004; HKCA 1006; HKCA 1007; HKCA 1008; HKCA 1010; HKCA 1015; HKCA 1016; HKCA 1019; HKCA 1020; HKCA 1022; HKCA 1026; HKCA 1027; HKCA 1033; HKCA 1034; HKCA 1035; HKCA 1036; HKCA 1037; HKCA 1039; HKCA 1041; HKCA 1042; HKCA 1043; HKCA 1044; HKCA 1045; HKCA 1046; HKCA 1047; HKCA 1048; HKCA 1049; HKCA 1050; HKCA 1052; HKCA 1053; HKCA 1054; HKCA 1056; HKCA 1057; HKCA 1061; HKCA 1063; HKCA 1064; HKCA 1065; HKCA 1066; HKCA 1067; HKCA 1068; HKCA 1069; HKCA 1070; HKCA 1071; HKCA 1072; HKCA 1073
Article 2 paragraph 1 item (11)-19; Article 2 paragraph 1 item (11)-20; Article 2 paragraph 1 item (11)-20-2; Article 2 paragraph 1 item (11)-20-3; Article 2 paragraph 1 item (11)-21; Article 2 paragraph 1 item (11)-21-2; Article 2 paragraph 1 item (11)-22; Article 2 paragraph 1 item (11)-23; Article 2 paragraph 1 item (11)-24; Article 2 paragraph 1 item (11)-29; Article 2 paragraph 1 item (11)-30; Article 2 paragraph 1 item (11)-31; Article 2 paragraph 1 item (11)-32; Article 4 Paragraph 1 of Radio Law; Article 6 Paragraph 1 of the Enforcing Ordinance; MIC Notification No. 173; Japan- Public notice of MIC No.99(2004); IEC 61000-6-1; EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; IEC 61000-6-3; EN 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN 55016-2-1; CISPR 16-2-1; EN 303 446-1; EN 303 446-2; 3GPP TS 51.010-1 Ch 12.1.1, 12.1.2, 12.2.1, 12.2.2; 3GPP TS 34.124 Ch8.2; 3GPP TS 36.124 Ch8.2; 3GPP TS 38.124 Ch8.2; 3GPP TS25.113; 3GPP TS36.113; 3GPP TS36.124; 3GPP TS 36.101; ETSI TS 136 101; 3GPP TS 36.521-1; ETSI TS 136 521-1; ETSI TS 138 101-1; ETSI TS 138 101-3; 3GPP TS 38.521-1; ETSI TS 138 521-1; 3GPP TS 38.521-3; ETSI TS 138 521-3; RSS-102; EN 50385; IEC 62311; IEC 62479; EN 62479; EN 50663; EN50665; EN 62311; EN 62232; IEC 62232
ISO/IEC 17025:2017; CFR 47, FCC Part 15B; ANSI C63.4:20141; CFR 47, FCC Part 18; FCC MP-5:1986; ICES-GEN; ICES-003; ICES-001; ICES-005; IEC/CISPR 11, EN 55011; IEC/CISPR 15, EN 55015; IEC/CISPR 32; EN 55032; IEC/CISPR 35, EN 55035; IEC 61000-3-2, EN 61000-3-2; IEC 61000-3-3, EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3, EN 61000-4-3; IEC 61000-4-4, EN 61000-4-4; IEC 61000-4-5, EN 61000-4-5; IEC 61000-4-6, EN 61000-4-6; IEC 61000-4-8, EN 61000-4-8; IEC 61000-4-11, EN 61000-4-11; IEC 61000-4-39, EN 61000-4-39; IEC 60601-1-2, EN 60601-1-2; BS EN 55011; BS EN 55015; BS EN 55032; BS EN 55035; BS EN IEC 61000-3-2; BS EN IEC 61000-3-3; BS EN IEC 61000-4-2; BS EN IEC 61000-4-3; BS EN IEC 61000-4-4; BS EN IEC 61000-4-5; BS EN IEC 61000-4-6; BS EN IEC 61000-4-8; BS EN IEC 61000-4-11; BS EN 61000-4-39; BS EN 60601-1-2
CTIA 01.20; CTIA-01.40; CTIA MIMO OTA; CWG/CTIA WiFi OTA; 3GPP 34.114; 3GPP 37.544; QCVN 117:2023/BTTTT; WINNF-TS-0122 CBRS CBSD Test Specification; CBRSA-TS-9001 Certification Test Plan; WiFi Alliance AFC System to AFC Device Interface Specification; WiFi Alliance AFC Device (DUT) Compliance Test plan; WiFi Alliance AFC System (SUT) Compliance Test plan; ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02)
ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope documents we downloaded on 2026-03-14 and 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
13 lines
ISO/IEC 17025
Active5029.01
The scope document we hold says it is valid until 2026-11-30.
ISO/IEC 17065
Active5029.02
The scope document we hold says it is valid until 2026-11-30.
Location
Labs with overlapping accredited scope in United States
- HCT AmericaMilpitas, CA · under 1 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Bay Area ComplianceSunnyvale, CA · ~9 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Element Materials Technology San Jose, CASan Jose, CA · ~11 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Element Materials Technology Fremont NewarkFremont, CA · ~15 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- UL Verification ServicesFremont, CA · ~15 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.