Flow Systems
220 Bunyan Ave, 80513, Berthoud, CO, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 6799.01 · 4 lines
Below is the text of the scope document as published.
Part 1 of 4
(A2LA Cert. No. 6799.01) Revised 08/18/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 FLOW SYSTEMS INC. 220 Bunyan Ave Berthoud, CO 80513 Eric Davenport Phone: (970) 344-1670 CALIBRATION Valid To: November 30, 2026 Certificate Number: 6799.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Electrical – DC/Low Frequency Parameter / Equipment Range CMC2 (±) Comments DC Voltage – Measure (0 to 100) mV (10 to 100) V 0.0053 % + 0.38 µV 0.0053 % + 360 µV Agilent 34401A DC Current – Measure (0 to 100) mA 0.0053 % + 25 µA Agilent 34401A II. Fluid Quantities Parameter / Equipment Range CMC2, 4 (±) Comments Gas Flow - Volumetric (10 to 500) sccm (500 to 50 000) sccm 0.46 % 0.47 % Meas Drycal Meas Drycal Gas Flow – Mass Flow Rate (5.5E-5 to 1.6) lbm/s (1.6 to 2.6) lbm/s (2.6 to 6.0) lbm/s 0.11 % 0.14 % 0.36 % Direct comparison using CFV on discharge coefficient
Part 2 of 4
(A2LA Cert. No. 6799.01) Revised 08/18/2025 Page 2 of 3 III. Mechanical Parameter / Equipment Range CMC2 (±) Comments Pressure – Measure Absolute/Gage (0.0015 to 1) psi (1 to 25) psi (25 to 100) psi (100 to 1000) psi 0.0018 % Full Scale 0.0015 % Full Scale 0.0028 % Full Scale 0.0038 % Full Scale Differential comparison Direct comparison with deadweight tester Pressure – Measure3 Absolute/Gage (10 to 40) inH2O (1 to 100) psi 0.03 % Full Scale 0.02 % Full Scale Direct comparison with pressure transducer IV. Thermodynamics Parameter / Equipment Range CMC2 (±) Comments Temperature – Measure (32 to 125) °F 0.04 °F Direct comparison SPRT with readout Temperature – Measure3 (32 to 125) °F 0.11 °F Direct comparison thermistor with readout Relative Humidity Measure/Generate (5 to 90) % RH 0.70 % RH Comparison with chilled mirror Dew Point Temperature – Measuring Equipment (-30 to 50) °C 0.47 °C Comparison with chilled mirror V. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure (0 to 300) kHz 0.10 + % 0.000 83 Hz Agilent 34401A ___________________________________________________
Part 3 of 4
(A2LA Cert. No. 6799.01) Revised 08/18/2025 Page 3 of 3 1 This laboratory offers commercial calibration service and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
Extracted from the scope document; tables may not line up. View scope for the original.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.