Registers refreshed 2026-11-08.See refresh dates
France

ALSTOM CRESPIN SAS - LABORATOIRE D'ESSAI

1 PLACE DES ATELIERS BP 1, 59154, CRESPIN, France

COFRAC 1-1630ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
6
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 6 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 15153-2
EN 15892
EN 50500
ISO 3095Railway applications - Acoustics - Measurement of noise emitted by railbound vehiclesSome clauses

Limits written next to it

EN ISO 3095 : 2013 (zone d'essai §5.2)

Some clauses. Written next to it on line 5 of COFRAC certificate 1-1630.

ISO 3381Railway applications - Acoustics - Noise measurement inside railbound vehicles
ISO 7731Ergonomics - Danger signals for public and work areas - Auditory danger signals

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-06.

Scope as published by COFRAC

8 lines
COFRAC

ISO/IEC 17025

Active

1-1630

The scope document we hold says it is valid until 2029-09-30.

View scope

Accredited scope, certificate 1-1630

LineMethodMatrixRange
1NF EN ISO/IEC 17025--
2LAB-RPI-MO-058 Version A; LAB-RPI-MO-059 Version AVéhicules ferroviaires; Appareillages de freins; Rail vehicles brake Equipments0 to 330 km/h
3LAB-RPI-MO-003 Version AStructures et organes de véhicules ferroviaires; Structures and organs of rail vehicles-
4LAB-RPI-MO-005 Version A; MO-06 révision 02Châssis de bogie; Traverse de charge; Traverse pivot; Eléments ferroviaires (rotules, absorbeurs…); Bogie frame Traverse load bolster rail elements (ball joints, absorbers ...)0 to 1000 kN
5UIC 643 O : 1980; EN ISO 3095 : 2013; EN ISO 3381 : 2011; EN ISO 3381 : 2021; ISO 7731 : 2008; UIC 644-O :1980; EN 15153-2 :2013; EN 15153-2 :2020; EN 15892 : 2011; STI LMR 2014/1302/EU; STI MR BRUIT 2014/1304/EU; EN ISO 3381 : 2011 (6.2); EN ISO 3381 : 2021 (6.2); EN ISO 3095 : 2013 (zone d'essai §5.2); STI PMR 2014/1300/UEMatériel roulant ferroviaire et sous systèmes-
6EN ISO 3381 : 2011; EN ISO 3381 : 2021; EN ISO 3095 : 2013; EN 15892 : 2011; STI PMR 2014/1300/UE; Document interne MO-62; UIC 651 : 2002 (§2.10); STI MR LOC & PAS 2014/1302/UE; STI LMR 2014/1302/EU; STI MR BRUIT 2014/1304/EU; STI MR GV 2008/232/CEMatériel roulant ferroviaire et sous systèmes-
7EN ISO 3381 : 2011; EN ISO 3381 : 2021; EN ISO 3095 : 2013; EN 15892 : 2011; STI MR LOC & PAS 2014/1302/UE; STI LMR 2014/1302/EU; STI MR BRUIT 2014/1304/EU; STI MR GV 2008/232/CE; Document interne MO-62Matériel roulant ferroviaire et sous systèmes-
8EN 50500 : 2008 + A1 : 2015Véhicules ferroviairesSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1 PLACE DES ATELIERS BP 1, CRESPIN, 59154, FR

50.41780, 3.66140

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.