Italy
CAFC spa - Divisione FRIULAB
Viale Palmanova 192, 33100, Udine, Italy
ACCREDIA|00476ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
4
Locations
1
Contact this laboratory
Register record
- ACCREDIACollected
- 00476Active
Certificates and scope
1ACCREDIA
ISO/IEC 17025
Active00476
Accredited scope, certificate 00476
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| biological | UNI CEI EN ISO/IEC 17025:2018; APHA Standard Methods for Examination of Water and Wastewater 9268 (2022); ISO 11731:2017; APAT CNR IRSA 7010 B Man 29 2003 MPN; APAT CNR IRSA 7030 B Man 29 2003 MPN; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; ISO 10304-4:2022; Rapporti ISTISAN 2007/31 pag 65 Met ISS BFA032; Rapporti ISTISAN 2007/05 pag 111 Met ISS A011B; EN ISO 6222:1999; ISO 9308-1:2014/Amd 1:2016; UNI EN ISO 7899-2:2003; UNI EN ISO 16266:2008 | Drinking water | 0 to 10 pH |
| chemical | APAT CNR IRSA 5080 Man 29 2003; APAT CNR IRSA 5060 Man 29 2003; Rapporti ISTISAN 2019/07; ISS CAC015; ISO 14189:2013; APAT CNR IRSA 2090 B Man 29 2003; APAT CNR IRSA 7030 F Man 29 2003; APAT CNR IRSA 7080 Man 29 2003; ISO 15587-2:2002; ISO 17294-2:2023; APHA Standard Methods for Examination of Water and Wastewater 3030 E (2020); APHA Standard Methods for Examination of Water and Wastewater 3125 (2020); ISO 23697-1:2023; UNI EN ISO 14911:2001; ISO 15705:2002 | Drinking water | 0.001 to ug/l |
| chemical | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 4020 Man 29 2003; APHA Standard Methods for Examination of Water and Wastewater 3030 E (2020); APHA Standard Methods for Examination of Water and Wastewater 3125 (2020); UNI EN ISO 14911:2001; UNI 11758:2019; APAT CNR IRSA 2110 Man 29 2003; ISO 23695:2023 | Drinking water | 0.1 to 10 NTU |
| environmental | APAT CNR IRSA 8020 B Man 29 2003; UNI EN ISO 10705-2:2001; CNR IRSA 7 Q 64 Vol 1 1983; CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008; CNR IRSA 1 Q 64 Vol 2 1984 | Acque naturali/Natural waters; Fanghi/Sludges; Rifiuti/Wastes | 0 to 100 % |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Location
Labs with overlapping accredited scope in Italy
- ECOPOINTAvezzano · ~447 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003APAT CNR IRSA 4020 Man 29 2003APAT CNR IRSA 5080 Man 29 2003
- LIFEANALYTICSOderzo · ~68 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008Drinking water
- ECO CONTROL LABORATORIO ASCOLANOFERMO · ~327 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 4020 Man 29 2003CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008Drinking water
- ALS ItaliaMoncalieri · ~450 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003APAT CNR IRSA 5080 Man 29 2003Drinking water
- ECOANALITICAOrbassano · ~460 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2060 Man 29 2003CNR IRSA 2 Q 64 Vol 2 1984/Notiziario IRSA 2 2008Drinking water
Accreditation data collected from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.