FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Canada

AGM Con-Test

Concord, Canada

A2LA|3029.01ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
3
Standards
0
Locations
4
One of 4 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at AGM Con-Test?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
3029.01Active

Accredited standards

We have not yet extracted the standard numbers from this lab’s scope document. The scope text we hold is below.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

3029.01

The scope document we hold says it is valid until 2028-07-31.

View scope

Accredited scope, certificate 3029.01

This scope has not been split into individual lines yet. Below is the text of the scope document as published.

Part 1 of 3

(A2LA Cert. No. 3029.01) Revised 07/09/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 AGM CON-TEST 116 Viceroy Road Building C, Units 11-12 Concord, Ontario, Canada L4K 2M3 Lyudmyla Boyko Phone: 905 760 9322 MECHANICAL Valid To: July 31, 2028 Certificate Number: 3029.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on metallic products: Test: Test Method(s) 1,2: Mechanical Properties Tension (≤ 600KN) ASTM E8/E8M, A370 n-Value (Strain Hardening Exponent) ASTM E646 r-Value (Plastic Strain Ratio) ASTM E517 Young’s Modulus ASTM E111 Charpy Impact (300 ft-lbs. max, Room Temperature to -80 °C, -196 °C) ASTM A370, E23 Bend Tests ASTM A370, E190, E290 Compression Test up to 600KN & 4 inch deflection SOP 16 Hardness Rockwell (HRB, HRC, 15T, 15N, 45N, 30T, 30N, 45T) ASTM A370, E18, F606; AP-200 Brinell Hardness-500kgf, 1500kgf & 3000kgf ASTM E10 Microhardness-Vickers 300 gf, 500gf, 1 kgf, 5 kgf, 10 kgf ASTM E92, E384, F606 Microhardness Knoop – 500gf E384 Case Depth SAE J423 Decarburization ASTM E1077 Metallography Preparation of Samples ASTM E3, E1920 Macroetching ASTM E340, E381 Microetching ASTM E407 Banding/Orientation of Microstructures ASTM E1268 Grain Size ASTM E112 (Comparison and Intercept Methods), E1181 Inclusion ASTM E45 Coating Weights ASTM A90/A90M, A428/A428M, ASTM Coating Thickness ASTM B487 Thermal Spray Coating Sample Preparation for Metallographic Examination ASTM E1920 Porosity Evaluation in Thermal Spray Coating ASTM E2109 Microstructure of Cast Iron ASTM A247

Part 2 of 3

(A2LA Cert. No. 3029.01) Revised 07/09/2026 Page 2 of 2 Test: Test Method(s) 1,2: Volume Fraction by Systematic Manual Point Count ASTM E562 Fastener Testing Wedge and Axial Tensile ASTM F606 Axial Proof Load (Internal and External Threads) ASTM F606 Welder Qualifications/Weld Process Qualification Using the Methods Listed Above in Accordance with ASME Section VIII, IX; AWS D1.1/D1.1M, D1.2/D1.2M, D17.1/D17.1M, IBR (Indian Boiler Regulations) Failure Analysis Using the Methods Listed Above in Accordance with the ASM Handbook Volume 11 Adhesion/Cohesion Test for Thermal Spray Coatings ASTM C633 Adhesion ASTM D3359 Chemical Chemical Analysis of Alloys with Optical Emission Spectroscopy (OES) Fe, Ni, Al & Cu Based Alloys ASTM E415; ASTM E1999; ASTM E1086, ASTM E3047, ASTM E1251, BS EN 15079 Corrosion Tests ASTM G48, A923 Pitting Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution ASTM G48 (Method A) Detrimental Intermetallic Phase in Duplex Austenitic/Ferritic Stainless Steels ASTM A923 (Method C) Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels ASTM A262 (Practice A) 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one year from the date of publication of the standard measurement method, per part C., Section 1 of A2LA R101 - General Requirements- Accreditation of ISO-IEC 17025 Laboratories. 2 The laboratory is accredited for the test methods listed above. The accredited test methods are used along with the guidance documents and material specifications listed below: API 5CT; ASME QW-462.1; ASTM A463, A653, E6 However, the inclusion of these guidance documents and material specifications on this Scope does not confer laboratory accreditation to the guidance documents and material specifications. Inclusion of these on this Scope also does not confer accreditation for every method embedded within them. Only the methods listed above on this Scope are accredited.

Part 3 of 3

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited AGM CON-TEST Concord, Ontario, CANADA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 6th day of July 2026. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3029.01 Valid to July 31, 2028 Revised July 9, 2026

Text extracted from the accredited scope document. Layout and tables from the original may not carry over; the scope document itself is the authoritative copy.

Other Locations

3 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.