Trescal, Inc. - Chicago, IL

718 West Algonquin Road, PO Box 559, 60005, Arlington Heights, IL, United States

Visit website
A2LA 1022.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
29
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 29 scope lines.

A2LA certificate 1022.03 · 29 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-to 60 °
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 2 of 28 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Indicators3 Up to 2 in 60 µin + 7.2 µin/in Indicator tester Micrometers3 Spindle Linearity Anvil Flatness Parallelism Up to 40 in Up to 50 µin Up to 50 µin 8.7 µin + 4.9 µin/in 7.3 µin 9.8 µin Gage blocks Optical flats Linear Displacement3 – Measuring Equipment Up to 40 in 61 µin + 4.1 µin/in Gage amplifier, gage blocks Plain Diameter – External (0.003 to 0.5) in 33 µin Laser micrometer, master pins Steel Tapes & Rulers3 Up to 100 ft 0.000 12 in + 0.2 µin/in Gage blocks, jeweler’s loupe Length Standards Up to 40 in 61 µin + 4.1 µin/in Gage amplifier, gage blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6, 7 (±) Comments DC Voltage – Generate3 (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 0.68 µV + 7 µV/V 1 µV + 6.2 µV/V 3.4 µV + 6.2 µV/V 6.4 µV + 6.2 µV/V 79 µV + 7 µV/V 0.48 mV + 9 µV/V Fluke 5700A w/wideband option DC Voltage – Generate, Fixed Points 1 V 1.018 V 10 V 4.2 µV/V 4.6 µV/V 0.68 µV/V Fluke 732A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 3 of 28 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments DC Voltage – Measure3 (0 to 1) mV (1 to 10) mV (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 25 nV + 52 µV/V 0.41 µV + 53 µV/V 0.33 µV + 13 µV/V 0.52 µV + 4 µV/V 8.8 µV + 4 µV/V 35 µV + 8 µV/V 0.2 mV + 8 µV/V Agilent 34420A Agilent 3458A Opt 002 DC High Voltage3 – Measure (1 to 10) kV (10 to 70) kV 0.04 % 0.044 % Vitrek 4700 w/HVL-70 DC Current – Generate3 Clamp Meter 3 0.1 nA to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (20 to 100) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 7.8 nA + 47 µA/A 8 nA + 46 µA/A 78 nA + 47 µA/A 0.8 µA + 62 µA/A 23 µA + 0.11 mA/A 0.38 mA + 0.28 mA/A 9.1 mA + 0.78 mA/A 0.013 % 56 mA + 7 mA/A 0.19 A + 4.3 mA/A 0.93 A + 4.3 mA/A Fluke 5700A Fluke 5700A w/ 5725A Fluke 5522A Agilent 3458A w/ Guildline 9211A Fluke 5522A w/ 5500A/coil DC Current – Measure3 Up to 2 nA (2 to 20) nA (20 to 200) nA (0.2 to 2) µA (2 to 20) µA (20 to 200) µA (0.2 to 2) mA (0 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 0.51 pA + 3 mA/A 7.1 pA + 2.1 mA/A 51 pA + 1.6 mA/A 0.51 nA + 1.6 mA/A 4.1 nA + 1.1 mA/A 41 nA + 1 mA/A 0.41 µA + 0.99 mA/A 41 pA + 89 µA/A 41 pA + 28 µA/A 0.4 nA + 24 µA/A 0.82 nA + 22 µA/A 5.8 nA + 24 µA/A 53 nA + 21 µA/A 0.53 µA + 37 µA/A 10 µA + 0.11 mA/A Keithley 486 Agilent 3458A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 4 of 28 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments DC Current – Measure3 (cont) (1 to 10) A (10 to 100) A (100 to 300) A (300 to 1500) A 0.0025 % 0.0052 % 0.0054 % 0.2 % Agilent 3458A w/: Guildline 9211A Empro shunt DC Resistance – Generate, Fixed Points 3 333 µΩ 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 1 Ω 10 kΩ 0.0046 % 0.0045 % 0.0018 % 0.0018 % 0.0014 % 0.0014 % 0.0014 % 0.0014 % 0.0014 % 8.9 µΩ 46 mΩ Guildline 9211A Fluke 742A-1 Fluke 742A-10K DC Resistance – Generate, Fixed Points 3 Up to 1000 V 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 39 µΩ 86 µΩ 0.16 mΩ 0.26 mΩ 0.46 mΩ 1.6 mΩ 3 mΩ 12 mΩ 22 mΩ 0.11 Ω 0.21 Ω 1.2 Ω 2.4 Ω 18 Ω 35 Ω 0.36 kΩ 0.81 kΩ 39 kΩ 21 Ω 0.38 kΩ 12 kΩ 0.61 MΩ 2.4 MΩ 0.36 GΩ 5 GΩ 0.15 TΩ Fluke 5700A IET VRS-100-8-1M- BP
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 5 of 28 Parameter/Equipment Range CMC2, 4, 6, 7 (±) Comments DC Resistance – Generate, Fixed Points3 (cont) Up to 5000 V 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 5.4 kΩ 50 kΩ 0.5 MΩ 5 MΩ 50 MΩ 0.5 GΩ 5 GΩ 0.27 TΩ IET VRS-100-8-1M- BP DC Resistance – Measure3 (0 to 1) Ω (1 to 10) Ω (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 3.2 µΩ + 71 µΩ/Ω 86 µΩ + 60 µΩ/Ω 55 µΩ + 15 µΩ/Ω 0.52 mΩ + 13 µΩ/Ω 0.53 mΩ + 10 µΩ/Ω 5.3 mΩ + 10 µΩ/Ω 53 mΩ + 11 µΩ/Ω 2.3 Ω + 17 µΩ/Ω 0.1 kΩ + 55 µΩ/Ω 1 kΩ + 0.52 mΩ/Ω 10 kΩ + 5.1 mΩ/Ω Agilent 34420A Agilent 3458A DC Resistance – Measure3 333 µΩ 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 0.0051 % 0.005 % 0.0028 % 0.0028 % 0.0025 % 0.0025 % 0.0025 % 0.0025 % 0.0025 % Current transfer method using Guildline 9211A, Agilent 3458A
0 to 10 TΩ
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 6 of 28 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Resistance – Generate3 Up to 10.9999 Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ (0.33 to 1.099 99) MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 1.1 mΩ + 23 µΩ/Ω 1.4 mΩ + 23 µΩ/Ω 2 mΩ + 22 µΩ/Ω 4.4 mΩ + 22 µΩ/Ω 9.8 mΩ + 22 µΩ/Ω 42 mΩ + 22 µΩ/Ω 98 mΩ + 22 µΩ/Ω 0.42 Ω + 22 µΩ/Ω 0.97 Ω + 22 µΩ/Ω 8.2 Ω + 25 µΩ/Ω 14 Ω + 25 µΩ/Ω 90 Ω + 47 µΩ/Ω 0.39 kΩ + 0.1 mΩ/Ω 4.2 kΩ + 0.19 mΩ/Ω 15 kΩ + 0.39 mΩ/Ω 0.34 MΩ + 2.3 mΩ/Ω 4.2 MΩ + 12 mΩ/Ω Fluke 5522A Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Generate3 Up to 2.2 mV (2.2 to 22) mV (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 3.9 µV + 0.47 mV/V 3.9 µV + 0.19 mV/V 3.9 µV + 93 µV/V 3.9 µV + 0.32 mV/V 6.2 µV + 0.74 mV/V 12 µV + 1 mV/V 23 µV + 1.4 mV/V 31 µV + 3.7 mV/V 5.7 µV + 0.47 mV/V 5.1 µV + 0.19 mV/V 4.9 µV + 93 µV/V 5.4 µV + 0.32 mV/V 7.9 µV + 0.74 mV/V 14 µV + 1 mV/V 27 µV + 1.4 mV/V 40 µV + 3.7 mV/V 23 µV + 0.47 mV/V 12 µV + 0.19 mV/V 9.7 µV + 85 µV/V 14 µV + 0.28 mV/V 39 µV + 0.7 mV/V 43 µV + 0.85 mV/V 63 µV + 1.4 mV/V 0.14 mV + 2.8 mV/V Fluke 5700A/5725A w/wideband option
to 1100 MΩ
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 7 of 28 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Voltage – Generate3 (cont) (0.22 to 2.2) V (2.2 to 22) V Amplitude Flatness Up to 1.1 mV (1.1 to 3) mV (3 to 11) mV (11 to 33) mV (33 to 110) mV (110 to 330) mV (0.33 to 1.1) V (1.1 to 3.5) V Referenced to 1 kHz Up to 1.1 mV (1.1 to 3) mV ≥ 3 mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 30 Hz to 500 kHz (10 to 30) Hz 30 Hz to 120 kHz 120 kHz to 2 MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz 120 kHz to 2 MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz 120 kHz to 2 MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.18 mV + 0.47 mV/V 55 µV + 0.14 mV/V 38 µV + 66 µV/V 40 µV + 0.11 mV/V 0.11 mV + 0.22 mV/V 0.2 mV + 0.37 mV/V 0.65 mV + 0.88 mV/V 1.2 mV + 1.9 mV/V 1.8 mV + 0.47 mV/V 0.55 mV + 0.14 mV/V 0.21 mV + 66 µV/V 0.4 mV + 0.11 mV/V 0.79 mV + 0.22 mV/V 2.4 mV + 0.47 mV/V 6.3 mV + 1.1 mV/V 12 mV + 2.3 mV/V 2.2 µV + 6.2 mV/V 8.4 µV + 5.4 mV/V 23 µV + 5.4 mV/V 68 µV + 4.7 mV/V 0.19 mV + 4.7 mV/V 0.51 mV + 3.9 mV/V 1.6 mV + 3.9 mV/V 3.8 mV + 3.1 mV/V 1.3 µV + 2.3 mV/V 0.44 µV + 0.76 mV/V 3.2 µV + 1.6 mV/V 4 µV + 3.1 mV/V 4.9 µV + 4.7 mV/V 18 µV + 12 mV/V 2.6 µV + 2.3 mV/V 0.86 µV + 0.77 mV/V 3.2 µV + 0.77 mV/V 4.9 µV + 2.3 mV/V 6.6 µV + 3.9 mV/V 15 µV + 12 mV/V 0.23 % 0.078 % 3 µV + 0.078 % 3 µV + 0.16 % 3 µV + 0.31 % 3 µV + 0.78 % Fluke 5700A/5725A w/wideband option
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 8 of 28 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Voltage – Generate3 (cont) Referenced to 1 kHz (22 to 220) V* (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz** 50 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 18 mV + 0.47 mV/V 5.5 mV + 0.14 mV/V 2.4 mV + 70 µV/V 7.7 mV + 0.19 mV/V 18 mV + 0.47 mV/V 0.11 V + 1.2 mV/V 0.18 V + 4.2 mV/V 0.39 V + 10 mV/V 95 mV + 0.36 mV/V 19 mV + 70 µV/V 36 mV + 0.13 mV/V 0.11 V + 0.46 mV/V 0.11 V + 0.46 mV/V 0.43 V + 1.8 mV/V Fluke 5700A/5725A w/wideband option *220 V range subject to 2.2E7 V-Hz limitation ** Maximum 250 V AC Voltage – Measure3 (0.1 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz 3.3 µV + 0.3 mV/V 1.3 µV + 0.2 mV/V 1.4 µV + 0.3 mV/V 2.1 µV + 1 mV/V 6.1 µV + 5 mV/V 42 µV + 40 mV/V 4.7 µV + 7 µV/V 2.7 µV + 7 µV/V 3.4 µV + 14 µV/V 5 µV + 0.3 mV/V 10 µV + 0.8 mV/V 40 µV + 3 mV/V 0.11 mV + 10 mV/V 0.16 V + 15 mV/V 47 µV + 7 µV/V 27 µV + 7 µV/V 35 µV + 14 µV/V 50 µV + 0.3 mV/V 0.1 mV + 0.8 mV/V 0.4 mV + 3 mV/V 1.1 mV + 10 mV/V 1.6 mV + 15 mV/V Agilent 3458A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 9 of 28 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Measure3 (cont) (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.47 mV + 7 µV/V 0.27 mV + 7 µV/V 0.34 mV + 14 µV/V 0.5 mV + 0.3 mV/V 1 mV + 0.8 mV/V 4 mV + 3 mV/V 11 mV + 10 mV/V 16 mV + 15 mV/V 6 mV + 0.2 mV/V 4 mV + 0.2 mV/V 4 mV + 0.2 mV/V 5.5 mV + 0.35 mV/V 14 mV + 1.2 mV/V 50 mV + 4 mV/V 0.16 V + 15 mV/V 56 mV + 0.4 mV/V 42 mV + 0.4 mV/V 56 mV + 0.6 mV/V 98 mV + 1.2 mV/V 0.22 V + 3 mV/V Agilent 3458A AC High Voltage3 – Measure (1 to 10) kV (10 to 50) kV 50/60/400 Hz 0.16 % 0.12 % Vitrek 4700 w/HVL-70 AC Flatness – Measure3,9 Up to 3 V 10 Hz 100 Hz 10 kHz 30 kHz 100 kHz 300 kHz 1 MHz 2 MHz 10 MHz 20 MHz 30 MHz 50 MHz 100 MHz 0.096 % 0.096 % 0.096 % 0.096 % 0.096 % 0.096 % 0.096 % 0.098 % 0.13 % 0.19 % 0.24 % 0.53 % 1.4 % Thermal voltage converter
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 10 of 28 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Current – Generate3 (0 to 220) µA (29 to 329.99) µA (0.22 to 2.2) mA (0.33 to 3.2999) mA (2.2 to 22) mA (3.3 to 32.999) mA (22 to 220) mA (33 to 329.99) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 66 nA + 0.5 mA/A 23 nA + 0.33 mA/A 17 nA + 0.12 mA/A 45 nA + 0.54 mA/A 93 nA + 1.4 mA/A 0.67 µA + 12 mA/A 0.18 µA + 0.62 mA/A 0.1 µA + 0.33 mA/A 59 nA + 0.12 mA/A 0.51 µA + 0.54 mA/A 1.1 µA + 1.4 mA/A 3.2 µA + 7.7 mA/A 1.8 µA + 0.62 mA/A 1 µA + 0.33 mA/A 0.59 µA + 0.12 mA/A 5.1 µA + 0.54 mA/A 11 µA + 1.4 mA/A 13 µA + 3.1 mA/A 18 µA + 0.62 mA/A 10 µA + 0.33 mA/A 6.2 µA + 0.14 mA/A 51 µA + 0.54 mA/A 0.11 mA + 1.4 mA/A 0.26 mA + 3.1 mA/A 0.16 mA + 0.58 mA/A 0.22 mA + 0.66 mA/A 1.9 mA + 7.8 mA/A 0.92 mA + 0.36 mA/A 1.9 mA + 0.74 mA/A 6.7 mA + 2.8 mA/A 14 mA + 0.9 mA/A 17 mA + 1.2 mA/A 0.26 A + 23 mA/A 34 mA + 2.9 mA/A 61 mA + 2.8 mA/A 0.46 A + 2.8 mA/A 0.064 A + 0.0064 A/A 0.11 A + 0.0057 A/A 0.92 A + 0.0057A/A 63 mA + 4.4 mA/A 0.23 A + 4.2 mA/A 1.2 A + 4.3 mA/A 93 mA + 7.6 mA/A 0.28 A + 7 mA/A 1.6 A + 7 mA/A Fluke 5700A Fluke 5522A Fluke 5700 w/ 5725A Fluke 5522A Fluke 5522A w/ 5500 coil
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 11 of 28 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments AC Current – Measure3 (5 to 100) µA (8.0 to 1) mA (1 to 10) mA (10 to 100) mA (8.0 to 1) A (1 to 20) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (8.0 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (8.0 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (8.0 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (8.0 to 5) kHz (5 to 20) kHz (20 to 50) kHz Up to 1 kHz (1 to 5) kHz 55 nA + 4 mA/A 42 nA + 1.5 mA/A 38 nA + 0.64 mA/A 0.41 µA + 4.1 mA/A 0.28 µA + 1.6 mA/A 0.24 µA + 0.67 mA/A 0.22 µA + 0.37 mA/A 0.24 µA + 0.67 mA/A 0.61 µA + 4.1 mA/A 1.8 µA + 5.6 mA/A 2.2 µA + 4.1 mA/A 2.1 µA + 1.6 mA/A 2 µA + 0.67 mA/A 2 µA + 0.37 mA/A 2 µA + 0.67 mA/A 4.2 µA + 4.1 mA/A 15 µA + 5.6 mA/A 40 µA + 4 mA/A 28 µA + 1.5 mA/A 23 µA + 0.6 mA/A 22 µA + 0.3 mA/A 23 µA + 0.6 mA/A 60 µA + 4 mA/A 0.18 mA + 5.5 mA/A 0.4 mA + 4.1 mA/A 0.28 mA + 1.7 mA/A 0.24 mA + 0.9 mA/A 0.25 mA + 1.1 mA/A 0.35 mA + 3.1 mA/A 0.9 mA + 10 mA/A 0.026 % 0.039 % Agilent 3458A Agilent 3458A, Fluke Y5020
5 to 100 µA
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 12 of 28 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF 0.4 to 1.0999) nF (1.1 to 3.299) nF (3.3 to 10.999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.0999) mF (1.1 to 3.2999) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110) mF (1 to 10) pF (10 to 100) pF (100 to 1000) pF (1 to 10) nF (10 to 100) nF 100 nF to 1.1 µF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz Up to 50 Hz Up to 20 Hz Up to 6 Hz Up to 2 Hz Up to 0.6 Hz Up to 0.2 Hz 1 kHz 8.5 pF + 3.8 pF/nF 9.4 pF + 3.9 pF/nF 12 pF + 3.9 pF/nF 15 pF + 2 pF/nF 0.1 nF + 1.9 pF/nF 0.14 nF + 1.9 pF/nF 0.45 nF + 1.9 pF/nF 1.4 nF + 1.9 nF/µF 4.4 nF + 1.9 nF/µF 14 nF + 1.9 nF/µF 58 nF + 3.1 nF/µF 0.19 µF + 3.5 nF/µF 0.62 µF + 3.5 nF/µF 1.9 µF + 3.5 µF/mF 6.8 µF + 3.4 µF/mF 38 µF + 2.4 µF/mF 87 µF + 5.8 µF/mF 0.36 mF + 8.5 µF/mF 0.12 pF 0.12 pF 0.13 pF + 0.015 % 0.31 pF + 0.016 % 1.8 pF + 0.027 % 26 pF + 0.045 % Fluke 5522A GenRad 1413 Capacitance – Measure3 (8.0 to 10) nF 10 nF to 10 µF (10 to 100) µF (100 to 1000) µF (1 to 10) mF (10 to 100) mF 100 Hz to 1 kHz 0.91 % 0.88 % 0.99 % 0.98 % 1.0 % 2.7 % Agilent U1252A Distortion3 (-101 to 0) dB (-70 to +10) dB 20 Hz to 20 kHz (20 to 100) kHz 100 kHz to 3 GHz (3 to 6.5) GHz (6.5 to 22) GHz (22 to 26.5) GHz 1.2 dB 2.3 dB 0.85 dB 1.9 dB 2.4 dB 3 dB Agilent U8903A Agilent E4440A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 13 of 28 Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Pulse Characterization3 – Rise & Fall Time Measure 350 ps to 1 ns 33 ps Agilent DSO8104A Oscilloscopes3 – Voltage DC into 50 Ω DC into 1 MΩ Squarewave into 50 Ω Squarewave into 1 MΩ Fast Edge into 50 Ω Leveled Sine Wave (Relative to 50 kHz) Leveled Sine Wave (Relative to 10 MHz) Time Marker ± (0 to 6.6) V ± (0 to 130) V 1 mV to 6.6 V p-p 1 mV to 130 Vp-p Nominal 150 ps 50 kHz Reference 50 kH to 100 MHz (100 to 300) MHz (300 to 500) MHz (500 to 600) MHz 10 MHz Reference 600 MHz to 1.6 GHz (1.6 to 2.1) GHz 5 s to 50 ms 20 ms to 200 ps 44 µV + 2.5 mV/V 31 µV + 0.25 mV/V 44 µV + 2.5 mV/V 17 µV + 0.5 mV/V 25 ps 0.41 mV + 20 mV/V 0.51 mV + 38 mV/V 0.54 mV + 45 mV/V 0.64 mV + 65 mV/V 0.67 mV + 72 mV/V 0.41 mV + 20 mV/V 0.74 mV + 86 mV/V 0.81 mV + 0.1 V/V 0.0003 % + 5 ns 0.000 033 % Fluke 5820A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 14 of 28 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate See Table below See Table below Fluke 5522A (45 to 65) Hz (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 % Ø 10 ° PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 % Ø 20 ° PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 % Ø 30 ° PF=0.866 0.11 % 0.12 % 0.13 % 0.2 % Ø 40 ° PF=0.766 0.16 % 0.17 % 0.23 % Ø 50 ° PF=0.643 0.21 % 0.22 % 0.27 % Ø 60 ° PF=0.500 0.31 % 0.35 % Ø 70 ° PF=0.342 0.48 % 0.49 % 0.51 % Ø 80 ° PF=0.174 0.99 % 1 % (65 to 500) Hz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % Ø 10 ° PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 % Ø 20 ° PF=0.940 0.17 % 0.18 % 0.2 % 0.26 % Ø 30 ° PF=0.866 0.26 % 0.28 % 0.33 % Ø 40 ° PF=0.766 0.37 % 0.39 % 0.42 % Ø 50 ° PF=0.643 0.53 % 0.56 % Ø 60 ° PF=0.500 0.76 % 0.77 % 0.78 % Ø 70 ° PF=0.342 1.2 % Ø 80 ° PF=0.174 2.5 %
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 15 of 28 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate See Table below See Table below Fluke 5522A 500 Hz to 1 kHz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Inductance – Generate3, Fixed Point 1 mH 10 mH 100 mH 1 H 10 H 100 µH to 1 mH (1 to 10) mH (10 to 100) mH 100 mH to 1 H (1 to 10) H 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 400 Hz & 1 kHz 0.65 µH 0.71 µH 0.49 µH 0.6 µH 0.47 µH 0.82 µH 0.87 µH 0.56 µH 0.54 µH 0.63 µH 4.5 µH 4.5 µH 4.4 µH 4.4 µH 4.4 µH 0.31 mH 0.27 mH 0.3 mH 0.6 mH 0.56 mH 0.61 mH 5.9 mH 0.015 µH + 0.0023 % 1 µH + 0.1 % 5.2 µH + 0.5 % 53 µH + 0.049 % 1.9 µH + 0.09 % GenRad 1482-E GenRad 1482-H GenRad 1482-L GenRad 106-M GenRad 1482-T GenRad 1491-G
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 16 of 28 Parameter/Equipment Range CMC2, 4 (±) Comments DC Power – Generate3 Up to 330 µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 1.1 A Up to 3 A Up to 11 A Up to 20.5 A Up to 1020 V Up to 337 mW (0.337 to 3.366) W (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.91) kW 0.017 % 0.021 % 0.0093 % 0.0093 % 0.019 % 0.043 % 0.044 % 0.13 % Fluke 5520A Duty Cycle3 (1 to 9.99) % (10 to 49.99) % At 50 % (50.01 to 90) % (90.01 to 99) % 0.32 % 0.02 % 0.013 % 0.02 % 0.032 % Fluke 5522A Electrical Calibration of RTDs – Measure3 Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω (-200 to 80) °C (-80 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 630) °C 0.019 °C 0.023 °C 0.027 °C 0.031 °C 0.038 °C 0.048 °C 0.018 °C 0.018 °C 0.02 °C 0.024 °C 0.029 °C 0.038 °C 0.017 °C 0.018 °C 0.019 °C 0.019 °C 0.025 °C 0.03 °C 0.036 °C 0.043 °C 0.054 °C 0.057 °C 0.061 °C 0.061 °C 0.071 °C 0.073 °C 0.09 °C Fluke 7526A
to 1020
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 17 of 28 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTDs – Measure3 (cont) Pt 385, 500 Ω Pt 385, 1000 Ω Ni 120, 120 Ω Cu 427, 10 Ω YSI 400 (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 260) °C (-100 to 260) °C (15 to 50) °C 0.029 °C 0.029 °C 0.036 °C 0.041 °C 0.049 °C 0.02 °C 0.02 °C 0.027 °C 0.03 °C 0.038 °C 0.0097 °C 0.11 °C 0.0071 °C Fluke 7526A Electrical Calibration of RTDs – Generate3 PT 385, 100 Ω PT 3926, 100 Ω PT 3916, 100 Ω PT 385, 200 Ω PT 385, 500 Ω PT 385, 1000 Ω Ni 120, 120 Ω Cu 427, 10 Ω YSI 400 (-200 to 800) °C (-200 to 630) °C (-200 to 630) °C (-200 to 400) °C (400 to 630) °C (-200 to 630) °C (-200 to 630) °C (-80 to 260) °C (-100 to 260) °C (15 to 50) °C 0.052 °C 0.052 °C 0.052 °C 0.4 °C 0.5 °C 0.17 °C 0.091 °C 0.021 °C 0.38 °C 0.009 °C Fluke 7526A
-200 to 800 °C
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 18 of 28 Parameter/Equipment Range CMC2 (±) Comments Thermal Reference Probes (Half Junctions) Type E Type J Type K Type T 0 °C 0 °C 0 °C 0 °C 0.12 °C 0.12 °C 0.13 °C 0.13 °C Omega ice point, Fluke 5700A, Agilent 3458A Thermocouple – Indicating Systems & Measure3 Type B Type C Type E Type J Type K Type L (600 to 800) °C (800 to 1550) °C (1550 to 1820) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2000) °C (2000 to 2316) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-250 to -200) °C (-200 to -100) °C (-100 to 500) °C (500 to 800) °C (800 to 1372) °C (-200 to -100) °C (-100 to 900) °C 0.35 °C 0.28 °C 0.23 °C 0.16 °C 0.23 °C 0.27 °C 0.36 °C 0.25 °C 0.12 °C 0.091 °C 0.082 °C 0.1 °C 0.14 °C 0.091 °C 0.11 °C 0.46 °C 0.16 °C 0.1 °C 0.1 °C 0.14 °C 0.1 °C 0.092 °C Fluke 7526A
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 19 of 28 Parameter/Equipment Range CMC2 (±) Comments Thermocouple – Indicating Systems & Measure3 (cont) Type N Type R Type S Type T Type U (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 200) °C (200 to 400) °C (-200 to 0) °C (0 to 200) °C (200 to 600) °C 0.73 °C 0.23 °C 0.12 °C 0.11 °C 0.1 °C 0.13 °C 0.55 °C 0.45 °C 0.39 °C 0.28 °C 0.22 °C 0.21 °C 0.2 °C 0.24 °C 0.51 °C 0.43 °C 0.38 °C 0.29 °C 0.23 °C 0.22 °C 0.22 °C 0.27 °C 0.35 °C 0.16 °C 0.14 °C 0.12 °C 0.12 °C 0.23 °C 0.1 °C 0.1 °C Fluke 7526A
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 20 of 28 III. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments Amplitude Modulation3 – Measure (5 to 99) % depth (5 to 20) % depth (20 to 99) % depth (5 to 20) % depth (20 top 99) % depth 100 kHz to 10 MHz 10 MHz to 3 GHz (3 to 26.5) GHz 0.86 % of depth 2.6 % of depth 0.78 % of depth 4.6 % of depth 1.7 % of depth Agilent E4440A Frequency Modulation3 – Measure Modulation rate: 20 Hz to 10 kHz Deviation: 200 Hz to 40 kHz Modulation rate: 50 Hz to 200 kHz Deviation: 250 Hz to 400 kHz 250 kHz to 10 MHz 10 MHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 26.5) GHz 1.5 % 1.5 % 2.5 % 3.8 % Agilent E4440A Phase Modulation3 – Measure (0.3 to ≤ 0.7) rad > 0.7 rad (0.6 to ≤ 2.0) rad 2.0 rad (1.2 to ≤ 4.0) rad > 4.0 rad 100 kHz to 6.6 GHz (6.6 to 13.2) GHz (13.2 to 26.5) GHz 3 % 8.0 % 3 % 1.1 % 3 % 1.1 % Agilent E4440A
5 to 99 %
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 21 of 28 Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments Relative Power3 – Measure (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -130) dB 100 kHz to 26.5 GHz 0.031 dB 0.035 dB 0.039 dB 0.058 dB 0.06 dB 0.064 dB 0.077 dB 0.082 dB 0.086 dB 0.096 dB 0.1 dB 0.11 dB 0.12 dB Agilent E4440A Absolute Power – Measure3 (-20 to +30) dBm (-60 to +20) dBm (-70 to +20) dBm (-20 to +30) dBm 100 kHz to 4.2 GHz 9 kHz to 6 GHz 50 MHz to 3 GHz (3 to 9.2) GHz (9.2 to 13.5) GHz (13.5 to 22) GHz (22 to 26.5) GHz 50 MHz to 3 GHz (3 to 9.2) GHz (9.2 to 13.5) GHz (13.5 to 22) GHz (22 to 26.5) GHz 3.7 % 3.7 % 3.8 % 3.9 % 4.1 % 4.4 % 4.7 % 3.8 % 3.9 % 4.1 % 4.4 % 4.7 % Agilent N1914A w/: Agilent N5532B Agilent E9304A Agilent E4413A Agilent N5532A
22--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 22 of 28 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Attenuation – Measure3 (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB 10 MHz to 26.5 GHz 0.039 dB 0.042 dB 0.045 dB 0.062 dB 0.064 dB 0.068 dB 0.081 dB 0.085 dB 0.089 dB 0.099 dB 0.11 dB 0.11 dB 0.13 dB Agilent E4440A Attenuation – Generate3 (1 to 11) dB (10 to 60) dB (70 to 110) dB (110 to 121) dB DC to 4 GHz 0.21 dB 0.3 dB 0.31 dB 0.32 dB HP 8494G & HP 8496G step attenuators Displayed Average Noise Level3 (-160 to -50) dBm 45 MHz to ≤ 2 GHz (2 to ≤ 3) GHz (3 to ≤ 6) GHz (6 to ≤ 9) GHz 0.73 dB 0.85 dB 0.92 dB 1.1 dB Agilent 85032F 50 Ω termination Return Loss (VSWR)3 Up to 60 dB (Up to 1:1 VSWR) (100 to 300) kHz 300 kHz to 1 GHz (1 to 3) GHz (2 to 12.4) GHz (12.4 to 18) GHz (18 to 26.5) GHz 1.1 dB 1.0 dB 1.1 dB 1.4 dB 1.8 dB 2.8 dB Agilent E4440A w/: directional coupler & SWR bridge
to 60 dB
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 23 of 28 Parameter/Range Frequency CMC2, 4, 5, 6 (±) Comments Single Side-Band Phase Noise3 – Measure Carrier: 1 MHz to 26.5 GHz At offsets: 10 Hz 100 Hz 1 kHz 10 kHz 20 kHz 100 kHz 1 MHz 10 MHz 2.7 dB 2.7 dB 2.5 dB 2.4 dB 2.4 dB 2.4 dB 2.4 dB 2.4 dB Agilent E4440A (see below) E4440A system noise floor limits SSB measurements at the following offsets as indicated Up to 600 MHz 601 MHz to 10.1 GHz (10.3 to 26.5) GHz 10 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz 100 Hz offset -102 dBc/Hz -84 dBc/Hz -76 dBc/Hz 1 kHz offset -114 dBc/Hz -104 dBc/Hz -95 dBc/Hz 10 kHz offset -120 dBc/Hz -114 dBc/Hz -105 dBc/Hz 100 kHz offset -125 dBc/Hz -120 dBc/Hz -120 dBc/Hz 1 MHz offset -150 dBc/Hz -145 dBc/Hz -158 dBc/Hz 10 MHz offset -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz
24EURAMET CG-18-to 7.4 kg
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 25 of 28 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Torque – Measure Tools3 (4 to 8) ozf·in (8 to 40) ozf·in (5 to 50) lbf·in (20 to 200) lbf·in (50 to 100) lbf·in (100 to 500) lbf·in (25 to 50) lbf·ft (50 to 250) lbf·ft (30 to 300) lbf·ft (5 to 50) lbf·in (40 to 400) lbf·in (100 to 1000) lbf·in (25 to 250) lbf·ft (60 to 600) lbf·ft 1.2 % 0.58 % 0.59 % 0.33 % 1.2 % 0.6 % 1.2 % 0.59 % 0.13 % 0.3 % 0.3 % 0.31 % 0.3 % 0.31 % Mountz BMX40Z TL-50i AKO TSD011/020 BMX500I BMX250F AKO TSD321BT CDI 2000-400-02 CDI 2000-12-02 Pressure – Measure & Measuring Equipment3 Hydraulic Pneumatic (10 to 10 000) psig (0 to 5) inH2O (0 to 25) inH2O (8 to 17) psia (-15 to 83) psig (83 to 150) psig (-15 to 758) psig (758 to 1500) psig 0.018 % 0.096 % 0.082 % 0.023 % 0.019 psi 0.023 % 0.18 psi 0.023 % Ametek DM-T-150 DWT Ashcroft AQS-1 Ashcroft AM2-1 Mensor CPC4000
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 26 of 28 VI. Thermodynamics Parameter/Equipment Range CMC2, 4, 5, 6 (±) Comments Temperature – Measure3 (-197 to 0) °C (0 to 420) °C (420 to 600) °C 0.028 °C + ΔTChange from -197 °C x 0.000 058 °C 0.017 °C + 0.000 054 °C/°C 0.042 °C + ΔTChange from 420 °C x 0.000 23 °C Fluke 1502A w/ 5614 PRT 5614 PRT 5609 PRT Temperature – Measuring Equipment3 -78 °C (-45 to 140) °C (-30 to 125) °C (35 to 200) °C (35 to 420) °C (420 to 600) °C 0.074 °C 0.065 °C 0.046 °C + ΔTChange from -30 °C x 0.000 18 °C 0.038 °C + ΔTChange from 35 °C x 0.000 088 °C 0.065 °C + ΔTChange from 35 °C x 0.000 067 °C 0.092 °C + ΔTChange from 420 °C x 0.000 14 °C Fluke 1502A w/ 5614 PRT, 5609 PRT, dry wells, dry ice bath Infrared Temperature – Measuring Equipment Emissivity = 0.95 Wavelength (8 to 14) µm (-15 to -12) °C (-12 to -8) °C (-8 to -4) °C (-4 to 0) °C (0 to 120) °C (35 to 500) °C 0.51 °C 0.5 °C 0.49 °C 0.48 °C 0.6 °C + 0.0017 °C/°C 0.54 °C + ΔTChange from 35 °C x 0.0042 °C Hart 4180 Hart 4181 Relative Humidity – Measuring Equipment3 (15 to 80) % RH (> 80 to 95) % RH 1.4 % RH 2.1 % RH Kaymont 2000 Relative Humidity – Measure3 (20 to 90) % RH (90 to 95) % RH 1.4 % RH 2.1 % RH Vaisala MI70 & HMP77
27NIST 960-12-See scope document
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1022.03) 07/16/2024 Page 28 of 28 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, R is the numerical value of the resolution of the device in its respective units and percentages are percentage of reading unless otherwise indicated. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 CMC components that can be reasonably attributed to the Unit Under Test have not been utilized in the calculation of the CMC value for this measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as eit her a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 8 This scope meets A2LA’s P112 Flexible Scope Policy 9 For frequencies that fall in between the stated cardinal points, the CMC can be calculated by interpolating the uncertainty from the frequency above and below the frequency of interest.
29ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

718 West Algonquin Road, PO Box 559, Arlington Heights, IL, 60005, US

42.08116, -87.98022

Open in Maps