Eko-Projekt W. Z. Żywczyk Spółka Jawna
ul. J. Kilińskiego 49 L, 27-400, Ostrowiec Św., Poland
Visit website- Accredited standards
- 33
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 33 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO22
ISO 5664Water quality - Determination of ammonium - Distillation and titration method
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6058Water quality - Determination of calcium content - EDTA titrimetric method
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9280Water quality - Determination of sulfate - Gravimetric method using barium chloride
Show all 22
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 11905-1Water quality - Determination of nitrogen - Part 1: Method using oxidative digestion with peroxodisulfate
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN6
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 903Water quality. Determination of anionic surfactants by measurement of the methylene blue index MBAS
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
ISO 5667 series3
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
Other standards2
C-04554-4:1999
PN-C-04614-03
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010; PN-ISO 9280:2002; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-ISO 5664:2002; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 903:2002; PB 032 wydanie 1 z dnia 20.04.2017 r.; PB 021 wydanie 1 z dnia 20.03.2010 r.; PB 019 wydanie 1 z dnia 01.09.2010 r.; PB 009 wydanie 2 z dnia 16.04.2020 r.; PB 004 wydanie 1 z dnia 01.03.2007 r.
PN-EN ISO 8467:2001; PB 032; PN-EN ISO 10523:2012; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10301:2002; PN-EN 26777:1999; PN-ISO 9297:1994; PN-ISO 6058:1999; PN-C-04554-4:1999; PN-ISO 6059:1999
PN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PN-EN ISO 11731:2017-08 +Ap1:2019-12P; PN-ISO 5667-5:2017-10; PN-EN ISO 16266:2009; PB 028; PB 031
PN-ISO 5667-6:2016-12+A11:2020-10; PB 025; PN-EN 1899-2:2002; PN-EN ISO 8467:2001; PB 034; PN-EN ISO 11905-1:2001; PN-ISO 5667-5:2017-10; PN-94/C-04576.04; PB 032; PN-ISO 6332:2001+Ap1:2016-06; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN 27888:1999
PN-EN ISO 10523:2012; PB 031; PN-EN ISO 8467:2001; PN-EN ISO 10301:2002; PN-EN 1622:2006
PN-EN 27888:1999; PN-94/C-04576.04; PN-EN ISO 9377-2:2003; PN-C-04614-03:1991; PB 036; PB 037; PB 038; PN-EN ISO 10301:2002
PN-ISO 5667-10:2021-11; PN-EN ISO 11905-1:2001; PN-77/C-04604.02
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.
Scope as published by PCA
8 lines
ISO/IEC 17025
ActiveAB 932
The scope document we hold says it is valid until 2028-08-24.
Accredited scope, certificate AB 932
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 932
Scope of accreditation No. AB 932
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
Nr AB 932
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 19 z/of 18.07.2025
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 932 z dnia 13.09.2019 r.
Cykl akredytacji od 23.07.2024 r. do 24.08.2028 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 932 of 13.09.2019
Accreditation cycle from 23.07.2024 to 24.08.2028
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 19, 18.07.2025 1/9
Nazwa i adres / Name and address
EKO-PROJEKT W. Z. Żywczyk Spółka Jawna
LABORATORIUM BADAŃ ŚRODOWISKOWYCH
ul. J. Kilińskiego 49L
27-400 Ostrowiec Świętokrzyski
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28/P; C/29/P;
C/30/P
- N/28/P; N/29/P;
N/30/P
- K/28/P; K/29/P
- Q/29/P
- Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi , ścieków / Chemical
tests and sampling of water, drinking water, sewage
- Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi , ścieków /
Tests of physical properties and sampling of water, drinking water, sewage
- Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi / Microbiological
tests and sampling of water, drinking water
- Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi / Sensory tests and sampling
of drinking water
Wersja strony / Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 932 | - |
| 2 | PN-ISO 5667-6:2016-12+A11:2020-10; PB 025; PN-EN 1899-2:2002; PN-EN ISO 8467:2001; PB 034; PN-EN ISO 11905-1:2001; PN-ISO 5667-5:2017-10; PN-94/C-04576.04; PB 032; PN-ISO 6332:2001+Ap1:2016-06; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN 27888:1999 | Drinking water | See scope document |
| 3 | PN-EN ISO 10523:2012; PB 031; PN-EN ISO 8467:2001; PN-EN ISO 10301:2002; PN-EN 1622:2006 | Drinking water | See scope document |
| 4 | PN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PN-EN ISO 11731:2017-08 +Ap1:2019-12P; PN-ISO 5667-5:2017-10; PN-EN ISO 16266:2009; PB 028; PB 031 | Drinking water | See scope document |
| 5 | PN-EN ISO 8467:2001; PB 032; PN-EN ISO 10523:2012; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10301:2002; PN-EN 26777:1999; PN-ISO 9297:1994; PN-ISO 6058:1999; PN-C-04554-4:1999; PN-ISO 6059:1999 | Pool water | See scope document |
| 6 | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010; PN-ISO 9280:2002; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-ISO 5664:2002; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 903:2002; PB 032 wydanie 1 z dnia 20.04.2017 r.; PB 021 wydanie 1 z dnia 20.03.2010 r.; PB 019 wydanie 1 z dnia 01.09.2010 r.; PB 009 wydanie 2 z dnia 16.04.2020 r.; PB 004 wydanie 1 z dnia 01.03.2007 r. | Water | See scope document |
| 7 | PN-EN 27888:1999; PN-94/C-04576.04; PN-EN ISO 9377-2:2003; PN-C-04614-03:1991; PB 036; PB 037; PB 038; PN-EN ISO 10301:2002 | Woda, ścieki | See scope document |
| 8 | PN-ISO 5667-10:2021-11; PN-EN ISO 11905-1:2001; PN-77/C-04604.02 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- "EKO-SERWIS" s.c. Dorota Markowska, Maciej MarkowskiŁódź · ~163 kmPCAShares 5 accredited methods and materialsEN ISO 10523:2012Drinking waterPool water
- SGS Polska Sp. z o.o.Pszczyna · ~204 kmPCAShares 5 accredited methods and materialsEN ISO 10523:2012Drinking waterPool water
- ALS Poland Sp. z o.o.Skoczów · ~224 kmPCAShares 5 accredited methods and materialsISO 5667-10:2021-11Drinking waterPool water
- LabAnalitykaBrzeg Dolny · ~329 kmPCAShares 5 accredited methods and materialsEN 1899-2:2002ISO 5667-10:2021-11Drinking water
- AQUANET Laboratorium Spółka z o.o.Poznań · ~349 kmPCAShares 5 accredited methods and materialsEN ISO 10523:2012EN ISO 19458:2007Drinking water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.