Eko-Projekt W. Z. Żywczyk Spółka Jawna

ul. J. Kilińskiego 49 L, 27-400, Ostrowiec Św., Poland

PCA|AB 932ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Eko-Projekt W. Z. Żywczyk Spółka Jawna?

Claim this profile to keep it accurate.

Register record

PCARefreshed
AB 932Active

Certificates and scope

1
PCA

ISO/IEC 17025

Active

AB 932

The scope document we hold says it is valid until 2028-08-24.

View on PCA

Accredited scope, certificate AB 932

LineDisciplineMethodMatrixRange
1chemical-Drinking water-
2chemicalPN-ISO 5667-6:2016-12+A11:2020-10; PB 025; PN-EN 1899-2:2002; PN-EN ISO 8467:2001; PB 034; PN-EN ISO 11905-1:2001; PN-ISO 5667-5:2017-10; PN-94/C-04576.04; PB 032; PN-ISO 6332:2001+Ap1:2016-06; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN 27888:1999Drinking water0.04 to 2700 0C; mg/l; µg/l; NTU; mg/l Pt; µS/cm
3chemicalPN-EN ISO 10523:2012; PB 031; PN-EN ISO 8467:2001; PN-EN ISO 10301:2002; PN-EN 1622:2006Drinking water0.1 to 100 mg/l; μg/l
4biologicalPN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PN-EN ISO 11731:2017-08 +Ap1:2019-12P; PN-ISO 5667-5:2017-10; PN-EN ISO 16266:2009; PB 028; PB 031Drinking water0.1 to 850 mV; mg/l
5chemicalPN-EN ISO 8467:2001; PB 032; PN-EN ISO 10523:2012; PN-EN ISO 7027-1:2016-09; PN-EN ISO 10301:2002; PN-EN 26777:1999; PN-ISO 9297:1994; PN-ISO 6058:1999; PN-C-04554-4:1999; PN-ISO 6059:1999Pool water0.01 to 1500 mg/l; NTU; μg/l; mg/l CaCO3
6chemicalPN-EN ISO 6878:2006+Ap1:2010+Ap2:2010; PN-ISO 9280:2002; PN-EN 872:2007+Ap1:2007; PN-EN ISO 10523:2012; PN-ISO 5664:2002; PN-EN ISO 5815-1:2019-12; PN-ISO 15705:2005; PN-ISO 6332:2001+Ap1:2016-06; PN-EN 903:2002; PB 032 wydanie 1 z dnia 20.04.2017 r.; PB 021 wydanie 1 z dnia 20.03.2010 r.; PB 019 wydanie 1 z dnia 01.09.2010 r.; PB 009 wydanie 2 z dnia 16.04.2020 r.; PB 004 wydanie 1 z dnia 01.03.2007 r.Drinking water0.04 to 20000 mg/l
7chemicalPN-EN 27888:1999; PN-94/C-04576.04; PN-EN ISO 9377-2:2003; PN-C-04614-03:1991; PB 036; PB 037; PB 038; PN-EN ISO 10301:2002Woda, ścieki0.005 to 2700 µS/cm; mg/l; μg/l
8chemicalPN-ISO 5667-10:2021-11; PN-EN ISO 11905-1:2001; PN-77/C-04604.02Waste water0.1 to 500 mg/l