Registers refreshed 2026-11-20.See refresh dates
France

INERIS

Parc Technologique ALATA B.P. n° 2, 60550, VERNEUIL EN HALATTE, France

COFRAC 1-0157ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
44
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 44 standard numbers and the 21 official names we hold. When no standard matches, it searches the method text of every scope line.

EN19
EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
EN 1948-1Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs - Part 1: Sampling of PCDDs/PCDFs
EN 12341
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 13211Air quality - Stationary source emissions - Manual method of determination of the concentration of total mercury
EN 13284-1Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14211
EN 14385Stationary source emissions - Determination of the total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl and V
EN 14625
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
Show all 19
EN 14791Stationary source emissions - Determination of mass concentration of sulphur oxides - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 15947-4
EN 16256-5
EN 16261-3
NF13
NF T70-500
NF T70-501
NF T70-502
NF T70-503
NF T70-504
NF T70-505
NF T70-506
NF T70-507
NF T70-508
NF X43-298
NF X43-329
NF X43-551
NF X 43-267
ISO 14451 series5
ISO 14451-2Pyrotechnic articles - Pyrotechnic articles for vehicles - Part 2: Test methods
ISO 14451-5Pyrotechnic articles - Pyrotechnic articles for vehicles - Part 5: Requirements and categorization for airbag gas generators
ISO 14451-6Pyrotechnic articles - Pyrotechnic articles for vehicles - Part 6: Requirements and categorization for airbag modules
ISO 14451-7Pyrotechnic articles - Pyrotechnic articles for vehicles - Part 7: Requirements and categorization for seatbelt pretensioners
ISO 14451-9Pyrotechnic articles - Pyrotechnic articles for vehicles - Part 9: Requirements and categorization for actuators
ISO3
ISO 12097-3Road vehicles - Airbag components - Part 3: Testing of inflator assembliesSome clauses

Limits written next to it

NF ISO 12097-3 §7.4

Some clauses. Written next to it on line 7 of COFRAC certificate 1-0157.

ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
Other standards4
FD X43-132
FD X43-140
XP X43-126
XP X43-554

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.

Scope as published by COFRAC

20 lines
COFRAC

ISO/IEC 17025

Active

1-0157

The scope document we hold says it is valid until 2029-05-31.

View scope

Location

Parc Technologique ALATA B.P. n° 2, VERNEUIL EN HALATTE, 60550, FR

49.27366, 2.51889

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.